Experimental Evaluation of the Shear Resistance of Corrugated Perfobond Rib Shear Connections

被引:35
|
作者
Kim, Sang-Hyo [1 ]
Ahn, Jin-Hee [1 ]
Choi, Kyu-Tae [1 ]
Jung, Chi-Young [1 ]
机构
[1] Yonsei Univ, Dept Civil & Environm Engn, Seoul 120749, South Korea
关键词
shear behavior; corrugated perfobond rib; perfobond rib; shear connector; shear resistance; push-out test; BEHAVIOR; STEEL;
D O I
10.1260/1369-4332.14.2.249
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Push-out tests were carried out to examine the shear strength of corrugated perfobond rib shear connections. The corrugated perfobond rib shear connection, formed by folding the straight perfobond rib steel panel, can be expected to increase the shear capacity and ductility of a shear connector due to the shear resistance and deformation of the inclined rib panel. To examine the shear behaviour of the corrugated perfobond rib connection and compare it with that of the perfobond rib, the push-out specimens were fabricated to suit the shear corrugated rib resistance parameters of depth of rib, height of rib, holes in the corrugated rib and whether transverse rebar is placed in the corrugated rib holes. Results of the push-outs show that the failure of corrugated perfobond rib shear connection is determined by concrete bearing and small deformations of inclined perfobond rib panel. Specifically, the corrugated rib specimens showed different relative slips at each side of the composite interface owing to the stress flow along the inclined rib developed by inclined direction of the welded corrugated perfobond rib. The transverse rebar in the rib hole reduced the difference in relative slips. The shear strength of the corrugated connection is increased by about 198 similar to 512% compared with the standard perfobond rib specimen connection with transverse rebars and without transverse rebars respectively. However, the contribution of other shear resistance parameters is found to be relatively small compared with the contribution provided by transverse rebars in the rib holes. In terms of the ductility of the shear connector, the relative slip of the corrugated rib connections increased after ultimate load, so it is evaluated to have a sufficient ductility.
引用
收藏
页码:249 / 263
页数:15
相关论文
共 50 条
  • [1] Experimental shear resistance evaluation of Y-type perfobond rib shear connector
    Kim, Sang-Hyo
    Choi, Kyu-Tae
    Park, Se-Jun
    Park, Seung-Min
    Lung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 82 : 1 - 18
  • [2] Experimental study on the shear resistance of a comb-type perfobond rib shear connector
    Gu, Jian-Cheng
    Liu, Duo
    Deng, Wen-Qin
    Zhang, Jian-Dong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 158 : 279 - 289
  • [3] Influence of coarse aggregates on the shear resistance of perfobond rib shear connector
    Manabe, Yota
    Fujiyama, Chikako
    Kisaku, Tomoaki
    Shionaga, Riyousuke
    2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS, 2014, 95 : 454 - 464
  • [4] Shear Resistance of Perfobond Rib Shear Connectors under Cyclic Loading
    Zhao, Canhui
    Wang, Yuechen
    Zhu, Shengchun
    Deng, Kailai
    Li, Zhixiang
    Yuan, Xing
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (02)
  • [5] Shear resistance of the perfobond-rib shear connector depending on concrete strength and rib arrangement
    Ahn, Jin-Hee
    Lee, Chan-Goo
    Won, Jeong-Hun
    Kim, Sang-Hyo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (10) : 1295 - 1307
  • [6] Generalized formulation for shear resistance on Y-type perfobond rib shear connectors
    Kim, Sang-Hyo
    Park, Sejun
    Kim, Kun-Soo
    Jung, Chi-Young
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 128 : 245 - 260
  • [7] Bearing mechanisms of perfobond rib shear connectors by experimental investigation
    Meng, Hao
    Xu, Rongqiao
    ENGINEERING STRUCTURES, 2025, 326
  • [8] Shear resistance characteristic and ductility of Y-type perfobond rib shear connector
    Kim, Sang-Hyo
    Park, Se-Jun
    Heo, Won-Ho
    Jung, Chi-Young
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (02): : 497 - 517
  • [9] Evaluation of fibre-reinforced polymer perfobond rib shear connector resistance tests
    Kolpasky, L.
    Ryjacek, P.
    ADVANCES AND TRENDS IN ENGINEERING SCIENCES AND TECHNOLOGIES II, 2017, : 159 - 164
  • [10] Experimental and Numerical Evaluation of Perfobond Rib Shear Connectors Embedded in Recycled Aggregate Concrete
    Yu, Zhenxuan
    He, Shaohua
    Mosallam, Ayman S.
    Jiang, Shuo
    Feng, Wenxian
    ADVANCES IN CIVIL ENGINEERING, 2020, 2020