Fracture resistance of fiber-reinforced composite restorations with different framework design

被引:15
作者
Behr, M [1 ]
Rosentritt, M [1 ]
Taubenhansl, P [1 ]
Kolbeck, C [1 ]
Handel, G [1 ]
机构
[1] Univ Regensburg, Sch Dent, Dept Prosthodont, D-93042 Regensburg, Germany
关键词
fiber-reinforced composite; framework design; fracture resistance; inlay fixed partial dentures;
D O I
10.1080/00016350510019793
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Veneer fracture and bond deficiency between framework and veneer are typical failures of fiber-reinforced inlay fixed partial dentures (FPD). An eccentric load point on the pontic was used in this study to investigate the fracture resistance of FPDs with different framework designs. As null hypothesis, it was assumed that fracture resistance was not influenced by the fiber framework supporting the veneer. Methods. Four groups of Vectris/Adoro FPDs (4 x n = 10 each) were manufactured. Beams (25 mm length) of Vectris Pontic ( parallel aligned) with ( a) rectangular (3 x 3) sectional view and (b) circular sectional view (circle divide 3 mm) were directly veneered using Adoro. ( c) Circular beams like "b" were modified, i.e. those on the upper side were coated with two layers of the cross-sectioned fiber mat Vectris frame. (d) Vectris Pontic fibers were "anatomically" placed in the pontic area and wrapped using Vectris Frame. The frameworks were constructed in a vacuum/pressure process. All FPDs were mounted in a restrained-end apparatus and thermally cycled and mechanically loaded (TCML: 6000 x 5 degrees C/55 degrees C; 1.2 x 10(6) x 50 N, 1.66 Hz). After TCML, the FPDs were loaded to fracture. Results. All FPDs surpassed TCML, with no visible damage to the veneer or framework. Without transversal enlargement of the framework, additional cross-sectioned fiber mats alone did not improve resistance to fracture (a: 573 +/- 158 N ( mean, standard deviation given); b: 737 +/- 66 N; c: 694 +/- 93 N; d: 902 +/- 149 N). Fracture lines occurred only in the veneer; the fiber frameworks were never affected. Conclusions. Anatomical enlargement of the fiber framework at the pontic area (height, width) to support the veneer material improves the fracture resistance of fiber-reinforced FPDs.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 20 条
[1]  
[Anonymous], MATERIALPRUFUNG
[2]  
Bae JM, 2001, INT J PROSTHODONT, V14, P33
[3]  
Behr M, 2003, INT J PROSTHODONT, V16, P239
[4]   In-vitro study of fracture strength and marginal adaption of fibre-reinforced adhesive fixed partial inlay dentures [J].
Behr, M ;
Rosentritt, M ;
Leibrock, A ;
Schneider-Feyrer, S ;
Handel, G .
JOURNAL OF DENTISTRY, 1999, 27 (02) :163-168
[5]  
Bohlsen F, 2003, QUINTESSENCE INT, V34, P493
[6]   Silane treatment effects on glass/resin interfacial shear strengths [J].
Debnath, S ;
Wunder, SL ;
McCool, JI ;
Baran, GR .
DENTAL MATERIALS, 2003, 19 (05) :441-448
[7]   Shear in flexure of fiber composites with different end supports [J].
Eckrote, KA ;
Burstone, CJ ;
Freilich, MA ;
Messer, GE ;
Goldberg, AJ .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (04) :262-266
[8]   Clinical evaluation of fiber-reinforced fixed bridges [J].
Freilich, MA ;
Meiers, JC ;
Duncan, JP ;
Eckrote, KA ;
Goldberg, J .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (11) :1524-1534
[9]  
GOEHRING TN, 2002, SCHWEIZER MONATSSCHR, V112, P127
[10]  
Göhring TN, 2002, AM J DENT, V15, P35