Effect of the atrial blanking time on the detection of atrial fibrillation in dual chamber pacing

被引:12
|
作者
Nowak, B
Kracker, S
Rippin, G
Horstick, G
Vincent, A
Geil, S
Himmrich, E
Meyer, J
机构
[1] Univ Mainz, Med Clin 2, D-6500 Mainz, Germany
[2] Vitatron Inc, Cologne, Germany
[3] Univ Mainz, Inst Med Stat, D-6500 Mainz, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2001年 / 24卷 / 04期
关键词
atrial fibrillation; atrial blanking time; atrial sensing; ventricular far-field sensing;
D O I
10.1046/j.1460-9592.2001.00496.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Patients with paroxysmal atrial fibrillation (PAF) and dual chamber pacemakers frequently have short postventricular atrial blanking times and sensitive atrial sensing thresholds used to provide reliable detection and mode switching during AF. However, short atrial blanking times increase the risk of atrial sensing of ventricular far-field signals. We evaluated if the length of the atrial blanking time influences the detection of AF. The study included ten patients with a VDDR (n = 7) or DDDR system (n = 3), who presented with AF at 18 follow-up visits. Bipolar atrial sensing was programmed to the most sensitive value. Atrial blanking times were programmed from 100 to 200 ms in 25-ms steps in each patient. Using marker annotation, the following parameters were measured at ten consecutive ventricular beats: VAF = the interval between ventricular events; and XAF = the interpolated number of atrial-sensed atrial-sensed events between two ventricular events; and XAF = the interpolated number of atrial-sensed events during atrial blanking time. The intervals between ventricular events and between atrial-sensed event markers showed no significant differences for the five blanking times tested. There was no significant influence of the atrial blanking time onto the measured parameters (least square means +/- standard error) with VAF between 281 +/- 12 and 300 +/- 12 ms (P = NS), AFs between 3.4 +/- 0.2 and 3.6 +/- 0.2 beats (P = NS) and XAF between 1.84 +/- 0.12 and 2.03 +/- 0.12 beats (P = NS). At ventricular rates < 100/min, the atrial sensing of AF in dual chamber pacemakers demonstrated no evidence for deterioration by an increase of the atrial blanking time from 100 to 200 ms. Thus, the risk of ventricular far-field sensing may be reduced without compromising atrial sensing.
引用
收藏
页码:496 / 499
页数:4
相关论文
共 50 条
  • [1] The relationship of atrial electrode position and atrial fibrillation in dual chamber pacing
    Seidl, K
    Drogemuller, A
    Hauer, B
    Schwick, N
    Zahn, R
    Senges, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1998, 87 (06): : 471 - 477
  • [2] Dual site right atrial pacing can improve the impact of standard dual chamber pacing on atrial and ventricular mechanical function in patients with symptomatic atrial fibrillation: Further observations from the Dual Site Atrial Pacing for Prevention of Atrial Fibrillation Trial
    Prakash, A
    Saksena, S
    Ziegler, PD
    Lokhandwala, T
    Hettrick, DA
    Delfaut, P
    Nanda, NC
    Wyse, DG
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 12 (03) : 177 - 187
  • [3] Clinical experience with the new detection algorithms for atrial fibrillation of a defibrillator with dual chamber sensing and pacing
    Kühlkamp, V
    Dörnberger, V
    Mewis, C
    Suchalla, R
    Bosch, RF
    Seipel, L
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (07) : 905 - 915
  • [4] Dual Site Right Atrial Pacing can Improve the Impact of Standard Dual Chamber Pacing on Atrial and Ventricular Mechanical Function in Patients with Symptomatic Atrial Fibrillation: Further Observations from the Dual Site Atrial Pacing for Prevention of Atrial Fibrillation Trial
    Atul Prakash
    Sanjeev Saksena
    Paul D. Ziegler
    Tasneem Lokhandwala
    Douglas A. Hettrick
    Phillipe Delfaut
    Navin C. Nanda
    D. George Wyse
    Journal of Interventional Cardiac Electrophysiology, 2005, 12 : 177 - 187
  • [5] DOES DUAL CHAMBER OR ATRIAL-PACING PREVENT ATRIAL-FIBRILLATION - THE NEED FOR A RANDOMIZED CONTROLLED TRIAL
    LAMAS, GA
    ESTES, NM
    SCHNELLER, S
    FLAKER, GC
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (08): : 1109 - 1113
  • [6] Low atrial septal pacing with dual-chamber pacemakers reduces atrial fibrillation in sick sinus syndrome
    Minamiguchi, Hitoshi
    Nanto, Shinsuke
    Onishi, Toshinari
    Watanabe, Tetsuya
    Uematsu, Masaaki
    Komuro, Issei
    JOURNAL OF CARDIOLOGY, 2011, 57 (02) : 223 - 230
  • [7] Increased base rate of atrial pacing for prevention of atrial fibrillation after implantation of a dual-chamber pacemaker: insights from the atrial overdrive pacing study
    Kantharia, Bharat K.
    Freedman, Roger A.
    Hoekenga, David
    Tomassoni, Gery
    Worley, Seth
    Sorrentino, Robert
    Steinhaus, David
    Wolkowicz, Joel M.
    Syed, Zaffer A.
    EUROPACE, 2007, 9 (11): : 1024 - 1030
  • [8] Effect of atrial pacing therapy with selective pacing algorithms on paroxysmal atrial fibrillation
    Pan, XH
    Zhang, XH
    Xu, G
    Fu, GS
    Shan, JA
    CHINESE MEDICAL JOURNAL, 2004, 117 (09) : 1401 - 1403
  • [9] Preventative atrial pacing for atrial fibrillation
    Wiegand, UKH
    ZEITSCHRIFT FUR KARDIOLOGIE, 2002, 91 (05): : 369 - 375
  • [10] Suppression of atrial fibrillation by atrial pacing
    Inoue, Noriko
    Ishikawa, Toshiyuki
    Sumita, Shinichi
    Kobayashi, Tsukasa
    Matsushita, Kohei
    Matsumoto, Katsumi
    Taima, Minoru
    Shimura, Miei
    Uchino, Kazuaki
    Kimura, Kazuo
    Umemura, Satoshi
    CIRCULATION JOURNAL, 2006, 70 (11) : 1398 - 1401