Clinical role of guidance by C-arm CT for 125I brachytherapy on pulmonary tumors

被引:6
作者
Jiao, Dechao [1 ]
Ren, Kewei [1 ]
Li, Zongming [1 ]
Shui, Shaofeng [1 ]
Han, Xinwei [1 ]
机构
[1] Zhengzhou Univ, Dept Intervent Radiol, Affiliated Hosp 1, Zhengzhou 450052, Henan, Peoples R China
来源
RADIOLOGIA MEDICA | 2017年 / 122卷 / 11期
关键词
C-arm computed tomography; Pulmonary tumors; Virtual navigation guidance; I-125; seeds; Brachytherapy; TRANSTHORACIC NEEDLE-BIOPSY; BEAM COMPUTED-TOMOGRAPHY; CELL LUNG-CANCER; IMPLANTATION; ACCURACY; SYSTEM; TIME; SEED;
D O I
10.1007/s11547-017-0791-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the clinical value of C-arm CT (CACT)-guided interstitial iodine-125 (I-125) brachytherapy on pulmonary tumors. 30 patients with 40 solid pulmonary tumors were enrolled to undergo CACT-guided interstitial I-125 brachytherapy between November 2011 and November 2014. The needle path was planned on a CACT virtual navigation and real-time fluoroscopy system. Technical success, puncture score, procedure time, local control rate (LCR), radiation exposure, complications and survival were investigated. The technical success of interstitial I-125 brachytherapy under CACT guidance was 40/40 (100%). The performance score was 4.7 +/- 0.5 with a mean total procedure time of 17.7 +/- 5.6 min. LCR in small (aecurrency2.0 cm), intermediate (2.1-4.9 cm) and large (aeyen5.0 cm) pulmonary tumors was 100, 89.5 and 72.7% at the 4-month follow-up, respectively. The mean effective dose was 10.1 +/- 2.8 mSv. Major complications occurred in four patients (13.3%). The mean survival time was 28.4 +/- 2.3 months. CACT can provide virtual navigation and real-time fluoroscopy synchronously for interstitial I-125 seed implantation on pulmonary tumors.
引用
收藏
页码:829 / 836
页数:8
相关论文
共 18 条
  • [1] CT-guided 125I brachytherapy for mediastinal metastatic lymph nodes recurrence from esophageal carcinoma: Effectiveness and safety in 16 patients
    Gao, Fei
    Li, Chuanxing
    Gu, Yangkui
    Huang, Jinhua
    Wu, Peihong
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : E70 - E75
  • [2] Gesztesi Laszlo, 2014, Magy Onkol, V58, P219
  • [3] C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance
    Guggenberger, Roman
    Ulbrich, Erika J.
    Dietrich, Tobias J.
    Scholz, Rosemarie
    Kaelin, Pascal
    Koehler, Christoph
    Elsaesser, Thilo
    Le Corroller, Thomas
    Pfammatter, Thomas
    Alkadhi, Hatem
    Andreisek, Gustav
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (02) : 454 - 463
  • [4] Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions
    Jiao, De-Chao
    Li, Teng-Fei
    Han, Xin-Wei
    Wu, Gang
    Ma, Ji
    Fu, Ming-Ti
    Sun, Qi
    Beilner, Janina
    [J]. DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (06) : 470 - 474
  • [5] C-arm cone-beam computed tomography with stereotactic needle guidance for percutaneous adrenal biopsy: initial experience
    Jiao, Dechao
    Xie, Na
    Wu, Gang
    Ren, JianZhuang
    Han, Xinwei
    [J]. ACTA RADIOLOGICA, 2017, 58 (05) : 617 - 624
  • [6] Radiofrequency ablation versus 125I-seed brachytherapy for painful metastases involving the bone
    Jiao, Dechao
    Wu, Gang
    Ren, Jianzhuang
    Han, Xinwei
    [J]. ONCOTARGET, 2016, 7 (52) : 87523 - 87531
  • [7] Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience
    Jiao, Dechao
    Huang, Kai
    Wu, Gang
    Wang, Yanli
    Han, Xinwei
    [J]. RADIOLOGIA MEDICA, 2016, 121 (10): : 769 - 779
  • [8] Flat detector C-arm CT-guided transthoracic needle biopsy of small (aparts per thousandcurrency sign2.0 cm) pulmonary nodules: diagnostic accuracy and complication in 100 patients
    Jiao, Dechao
    Yuan, Huifeng
    Zhang, Quanhui
    Han, Xinwei
    [J]. RADIOLOGIA MEDICA, 2016, 121 (04): : 268 - 278
  • [9] CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance
    Kim, Ga Ram
    Hur, Jin
    Lee, Sang Min
    Lee, Hye-Jeong
    Hong, Yoo Jin
    Nam, Ji Eun
    Kim, Hua Sun
    Kim, Young Jin
    Choi, Byoung Wook
    Kim, Tae Hoon
    Choe, Kyu Ok
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (02) : 232 - 239
  • [10] Accuracy of percutaneous soft-tissue interventions using a multi-axis, C-arm CT system and 3D laser guidance
    Kostrzewa, Michael
    Rathmann, Nils
    Kara, Kerim
    Schoenberg, Stefan O.
    Diehl, Steffen J.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) : 1970 - 1975