Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique

被引:3
|
作者
Arai, Hideo [1 ]
Kawakubo, Masateru [2 ]
Abe, Ko [1 ]
Hatashima, Hikaru [3 ]
Sanui, Kenichi [1 ]
Nishimura, Hiroshi [1 ]
Kadokami, Toshiaki [1 ]
机构
[1] Fukuokaken Saiseikai Futsukaichi Hosp, Fukuoka, Japan
[2] Kyushu Univ, Fac Med Sci, Dept Hlth Sci, Higashi Ku, 3-1-1 Maidashi, Fukuoka 8128582, Japan
[3] Oita Prefectural Hosp, Oita, Japan
关键词
Intramyocardial hemorrhage; Biomarker; Quantification; Semi-automated threshold method; Magnetic resonance imaging; Acute myocardial infarction; ELEVATION MYOCARDIAL-INFARCTION; LATE GADOLINIUM ENHANCEMENT; MICROVASCULAR OBSTRUCTION; ST-ELEVATION; MANAGEMENT; OUTCOMES; IMPACT; MRI;
D O I
10.1007/s10554-019-01697-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although intramyocardial hemorrhage (IMH) is a poor prognostic factor caused by ischemia reperfusion injury, little evidence is available regarding the association between IMH volume and biomarkers. In the present study, we measured IMH volume using three-dimensional (3D) T1-weighted magnetic resonance imaging (T1-MRI) and investigated its association with biomarkers. Moreover, the accuracy of semi-automatic measurement of IMH volume was validated. We retrospectively enrolled 33 consecutive patients (mean age 67 +/- 11 years) who underwent cardiac MRI after reperfusion therapy for acute myocardial infarction. IMH was observed in 4 patients (12.1%). Receiver operating characteristics (ROC) analysis of creatine kinase (CK) and CK-muscle/brain (CK-MB) tests for detecting IMH were performed. IMH volume measured using semi-automatic methods by a 2 standard deviation (SD) threshold was compared to manual measurements using the Spearman's correlation coefficient (rho) and Bland-Altman analyses. ROC analysis revealed optimal cutoff values of CK: 2460 IU/l and CK-MB: 231 IU/l (area under the curve: 0.95 and 0.91; sensitivity: 86% and 79%; specificity: 100% for both). IMH volume with the 2SD threshold correlated with that of the manual measurement [5.84 g (3.30 to 9.00) g vs. 8.07 g (5.37 to 9.33); rho: 0.85, p < 0.01; bias (limit of agreement): - 0.01 g (- 0.51 to 0.49); intraclass correlation coefficients 0.84 (0.75 to 0.90)]. Our findings could help identify the risk of IMH after reperfusion therapy with biomarkers. 3D T1-MRI can semi-automatically provide accurate IMH volume without being time-consuming.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 20 条
  • [1] Quantification of intramyocardial hemorrhage volume using magnetic resonance imaging with three-dimensional T1-weighted sequence in patients with ischemia-reperfusion injury: a semi-automated image processing technique
    Hideo Arai
    Masateru Kawakubo
    Ko Abe
    Hikaru Hatashima
    Kenichi Sanui
    Hiroshi Nishimura
    Toshiaki Kadokami
    The International Journal of Cardiovascular Imaging, 2020, 36 : 111 - 119
  • [2] Automated histogram-based brain segmentation in T1-weighted three-dimensional magnetic resonance head images
    Shan, ZY
    Yue, GH
    Liu, JZ
    NEUROIMAGE, 2002, 17 (03) : 1587 - 1598
  • [3] MR imaging of the brachial plexus using a T1-weighted three-dimensional volume acquisition
    vanEs, HW
    Witkamp, TD
    Ramos, LMP
    Feldberg, MAM
    Nowicki, BH
    Haughton, VM
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1996, 2 (03): : 264 - 273
  • [4] Clinical application of three-dimensional T1-weighted BrainVIEW in magnetic resonance imaging of cerebral venous thrombosis: a case report and literature review
    Yang, Cheng
    Fang, Huang
    Hu, Jun
    Li, Mei
    Wei, Chunxia
    Miao, Jinfei
    Huang, Wencai
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2023, 51 (04)
  • [5] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Yoon, Jeong Hee
    Lee, Jeong Min
    Lee, Eun Sun
    Baek, Jeehyun
    Lee, Sangwoo
    Iwadate, Yuji
    Han, Joon Koo
    Choi, Byung Ihn
    ABDOMINAL IMAGING, 2015, 40 (02): : 278 - 288
  • [6] Brain Extraction in Multiple T1-weighted Magnetic Resonance Imaging slices using Digital Image Processing techniques
    Duarte, Kaue T. N.
    Moura, Marinara A. N.
    Martins, Paulo S.
    de Carvalho, Marco A. G.
    IEEE LATIN AMERICA TRANSACTIONS, 2022, 20 (05) : 831 - 838
  • [7] Navigated three-dimensional T1-weighted gradient-echo sequence for gadoxetic acid liver magnetic resonance imaging in patients with limited breath-holding capacity
    Jeong Hee Yoon
    Jeong Min Lee
    Eun Sun Lee
    Jeehyun Baek
    Sangwoo Lee
    Yuji Iwadate
    Joon Koo Han
    Byung Ihn Choi
    Abdominal Imaging, 2015, 40 : 278 - 288
  • [8] Automated Quantification of Myocardial Salvage in a Rat Model of Ischemia-Reperfusion Injury Using 3D High-Resolution Magnetic Resonance Imaging (MRI)
    Grieve, Stuart M.
    Mazhar, Jawad
    Callaghan, Fraser
    Kok, Cindy Y.
    Tandy, Sarah
    Bhindi, Ravinay
    Figtree, Gemma A.
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2014, 3 (04):
  • [9] Three-dimensional assessment of coronary high-intensity plaques with T1-weighted cardiovascular magnetic resonance imaging to predict periprocedural myocardial injury after elective percutaneous coronary intervention
    Hosoda, Hayato
    Asaumi, Yasuhide
    Noguchi, Teruo
    Morita, Yoshiaki
    Kataoka, Yu
    Otsuka, Fumiyuki
    Nakao, Kazuhiro
    Fujino, Masashi
    Nagai, Toshiyuki
    Nakai, Michikazu
    Nishimura, Kunihiro
    Kono, Atsushi
    Komori, Yoshiaki
    Hoshi, Tomoya
    Sato, Akira
    Kawasaki, Tomohiro
    Izumi, Chisato
    Kusano, Kengo
    Fukuda, Tetsuya
    Yasuda, Satoshi
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [10] Automatic brain tissue extraction method using erosion-dilation treatment (BREED) from three-dimensional magnetic resonance imaging T1-weighted data
    Miura, N
    Taneda, A
    Shida, K
    Kawashima, R
    Kawazoe, Y
    Fukuda, H
    Shimizu, T
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (06) : 927 - 932