The energy saving potential of thermo-responsive desiccants for air dehumidification

被引:25
作者
Zeng, Yi [1 ]
Woods, Jason [1 ]
Cui, Shuang [1 ]
机构
[1] Natl Renewable Energy Lab, 15013 Denver West Pkwy, Golden, CO 80401 USA
关键词
Thermo-responsive solid desiccant; Desiccant wheel; Dehumidification; Energy efficiency; GEL PACKED-BEDS; MASS-TRANSFER; MOISTURE TRANSPORT; PERFORMANCE; WHEEL; HEAT; WATER; OPTIMIZATION; HYDROGEL; ISOTHERM;
D O I
10.1016/j.enconman.2021.114520
中图分类号
O414.1 [热力学];
学科分类号
摘要
The desiccant wheel is a promising technology for energy-efficient humidity control. However, its overall efficiency-hindered by the desiccant materials' properties-remains low because traditional desiccants (e.g., silica gels) have a single isotherm regardless of their adsorption temperature. Thermo-responsive materials have been proposed to break this fixed affinity to water vapor, with drastically different adsorption isotherms depending on temperature. Its potential for improving dehumidification efficiency, however, has not been addressed. In this paper, we model the potential of a thermo-responsive interpenetrating polymer network (IPN) desiccant with temperature-dependent adsorption isotherms for energy-efficient dehumidification via a validated transient desiccant wheel model for humidity control of buildings. Thermo-responsive desiccants can improve the dehumidification performance due to their thermo-responsive switchable hydrophilicity below/above the lower critical solution temperature. Our analysis shows that thermo-responsive IPN desiccants can potentially reduce energy consumption by up to 30% compared to silica gels. The savings depend strongly on the critical temperature of the thermo-responsive desiccant and should be higher when the inlet temperatures are expected to be higher.
引用
收藏
页数:17
相关论文
共 35 条
  • [21] Pesaran A.A., 1994, REV DESICCANT DEHUMI
  • [22] MOISTURE TRANSPORT IN SILICA-GEL PACKED-BEDS .1. THEORETICAL-STUDY
    PESARAN, AA
    MILLS, AF
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1987, 30 (06) : 1037 - 1049
  • [23] MOISTURE TRANSPORT IN SILICA-GEL PACKED-BEDS .2. EXPERIMENTAL-STUDY
    PESARAN, AA
    MILLS, AF
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1987, 30 (06) : 1051 - 1060
  • [24] Ritchie H., 2017, MEAT DAIRY PRODUCTIO
  • [25] ANALYTICAL INVESTIGATION OF HEAT OR MASS TRANSFER AND FRICTION FACTORS IN A CORRUGATED DUCT HEAT OR MASS EXCHANGER
    SHERONY, DF
    SOLBRIG, CW
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1970, 13 (01) : 145 - &
  • [26] Analysis of heat and mass transfer in porous sorbents used in rotary regenerators
    Sphaier, LA
    Worek, WM
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (14-16) : 3415 - 3430
  • [27] Heat and mass transfer modeling in rotary desiccant dehumidifiers
    Stabat, Pascal
    Marchio, Dominique
    [J]. APPLIED ENERGY, 2009, 86 (05) : 762 - 771
  • [28] Optimization of adsorption isotherm types for desiccant air-conditioning applications
    Sultan, Muhammad
    Miyazaki, Takahiko
    Koyama, Shigeru
    [J]. RENEWABLE ENERGY, 2018, 121 : 441 - 450
  • [29] A review of different strategies for HVAC energy saving
    Vakiloroaya, Vahid
    Samali, Bijan
    Fakhar, Ahmad
    Pishghadam, Kambiz
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 77 : 738 - 754
  • [30] Performance Analysis of a Combined Absorption Refrigeration-Liquid Desiccant Dehumidification THIC System Driven by Low-Grade Heat Source
    Xu, Cong
    Sui, Jun
    Dai, Yuze
    Liu, Feng
    Liu, Hao
    [J]. JOURNAL OF THERMAL SCIENCE, 2020, 29 (05) : 1193 - 1205