共 50 条
Analysis of the trace amount of metallic elements in iron and steels using the microwave decomposition by ICP-AES and ICP-MS
被引:8
作者:
Hanada, K
Kajima, Y
Fujimoto, K
Shimura, M
Satoh, S
机构:
[1] JFE Steel Corp, Steel Res Labs, Chuo Ku, Chiba 2600835, Japan
[2] JFE Steel Corp, Technol Planning Dept, Chiba 2600835, Japan
来源:
TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN
|
2003年
/
89卷
/
09期
关键词:
trace analysis;
determination;
decomposition under pressure;
external heating;
sample preparation;
microwave heating;
oxide;
alumina;
aluminum;
calcium oxide;
total amount;
iron;
steel;
EXCHANGE CHROMATOGRAPHY;
SPECTROMETRY;
BASE;
D O I:
10.2355/tetsutohagane1955.89.9_895
中图分类号:
TF [冶金工业];
学科分类号:
0806 ;
摘要:
Trace amount of metallic elements as At, Ca and Mn, which form oxides in iron and steels. were determined by ICP-AES and ICP-MS after the decomposition of samples using HF/HCl/HNO3 under microwave irradiation. The oxides in iron and steels, which were extracted by using Br-2-CH3OH extraction, could be decomposed by two-steps acid decomposition using H2SO4 followed by addition of HF in a pressurized vessel at elevated temperatures. The limits of detection for At, Ca, Mg, Mn, Cr, Ni, Cu, Zn and Co by microwave decomposition/ICP-MS were 0.01 similar to 0.36 ppm.
引用
收藏
页码:895 / 899
页数:5
相关论文