Improved stent expansion with prolonged compared with short balloon inflation: A meta-analysis

被引:6
作者
Saad, Marwan [1 ,2 ]
Bavineni, Mahesh [3 ]
Uretsky, Barry F. [1 ,4 ]
Vallurupalli, Srikanth [1 ,4 ]
机构
[1] Univ Arkansas Med Sci, Div Cardiol, Little Rock, AR 72205 USA
[2] Ain Shams Univ, Div Cardiovasc Med, Cairo, Egypt
[3] Univ Arkansas Med Sci, Div Hosp Med, Little Rock, AR 72205 USA
[4] Cent Arkansas Vet Healthcare Syst, Div Cardiol, Little Rock, AR USA
关键词
percutaneous coronary intervention; stent; stent deployment; OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; HIGH-PRESSURE; DEPLOYMENT; THROMBOSIS; TIME; PREDICTORS; GUIDANCE; OUTCOMES;
D O I
10.1002/ccd.27641
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Despite evidence from individual studies suggesting that prolonged inflation improves coronary stent expansion, relatively shorter inflation times are commonly employed in clinical practice. Methods We performed an electronic search of PubMed, Web of Science, Cochrane, and CINAHL databases to retrieve outcome studies comparing prolonged versus short inflation times during stent deployment. Outcomes studied included minimal stent diameter (MSD) and minimal stent area (MSA). Standardized mean difference (SMD) was used to estimate the effect sizes for these continuous variables. Results Seven studies with a total of 341 patients (415 lesions; mean age 67.6 years; 82% male) were included. Drug-eluting stents were used in 89 +/- 15% of coronary lesions. Prolonged stent inflation was associated with increased minimal stent diameter (2.93 +/- 0.34 mm vs. 2.72 +/- 0.28 mm; SMD = 0.42; 95% CI 0.25-0.59; P < 0.001) and minimal stent area (5.99 +/- 1.21 mm(2) vs. 5.17 +/- 0.87 mm(2); SMD = 0.46; 95% CI 0.19-0.73; P = 0.001) compared with shorter duration stent inflation. This difference remained significant in sensitivity analyses that excluded studies with very prolonged inflation duration or multiple stent balloon inflations. Conclusion Despite differences in duration and methodology, prolonged stent inflation is associated with improved expansion compared with shorter duration. The effect of this optimization recommends randomized trials to determine whether long-term outcomes can be improved by this simple technical modification.
引用
收藏
页码:873 / 880
页数:8
相关论文
共 26 条
  • [1] Better Inflation Time of Stent Balloon for Second-Generation Drug-Eluting Stent Expansion and Apposition: An Optical Coherence Tomography Study
    Ann, Soe Hee
    Chung, Jae-Wook
    Jin, Cai De
    Lee, Jun Ho
    Kim, Jong Min
    Garg, Scot
    Shin, Eun-seok
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (02) : 171 - 176
  • [2] Effect of balloon inflation time on expansion of sirolimus-eluting stent
    Asano, Tatsuhiko
    Kobayashi, Yoshio
    Fukushima, Kenichi
    Iwata, Yo
    Kitahara, Hideki
    Ishio, Naoki
    Nakayama, Takashi
    Kuroda, Nakabumi
    Komuro, Issei
    [J]. HEART AND VESSELS, 2009, 24 (05) : 335 - 339
  • [3] Incidence of stent under-deployment as a cause of in-stent restenosis in long stents
    Bertrand, OF
    De Larochellière, R
    Joyal, M
    Bonan, R
    Mongrain, R
    Tardif, JC
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2004, 20 (04) : 279 - 284
  • [4] Is adjunctive balloon postdilatation necessary after coronary stent deployment? Final results from the POSTIT trial
    Brodie, BR
    Cooper, C
    Jones, M
    Fitzgerald, P
    Cummins, F
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 59 (02) : 184 - 192
  • [5] Predictors of subacute stent thrombosis - Results of a systematic intravascular ultrasound study
    Cheneau, E
    Leborgne, L
    Mintz, GS
    Kotani, J
    Pichard, AD
    Satler, LF
    Canos, D
    Castagna, M
    Weissman, NJ
    Waksman, R
    [J]. CIRCULATION, 2003, 108 (01) : 43 - 47
  • [6] INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE
    COLOMBO, A
    HALL, P
    NAKAMURA, S
    ALMAGOR, Y
    MAIELLO, L
    MARTINI, G
    GAGLIONE, A
    GOLDBERG, SL
    TOBIS, JM
    [J]. CIRCULATION, 1995, 91 (06) : 1676 - 1688
  • [7] Prolonged High-Pressure is Required for Optimal Stent Deployment as Assessed by Optical Coherence Tomography
    Cook, Jeffrey R.
    Mhatre, Ajay
    Wang, Fen Wei
    Uretsky, Barry F.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (04) : 521 - 527
  • [8] Fitzgerald PJ, 2000, CIRCULATION, V102, P523
  • [9] Effect of Stent Inflation Pressure and Post-Dilatation on the Outcome of Coronary Artery Intervention. A Report of More than 90 000 Stent Implantations
    Frobert, Ole
    Sarno, Giovanna
    James, Stefan K.
    Saleh, Nawsad
    Lagerqvist, Bo
    [J]. PLOS ONE, 2013, 8 (02):
  • [10] Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting Stent implantation
    Fujii, K
    Carlier, SG
    Mintz, GS
    Yang, YM
    Moussa, I
    Weisz, G
    Dangas, G
    Mehran, R
    Lansky, AJ
    Kreps, EM
    Collins, M
    Stone, GW
    Lansky, AJ
    Kreps, EM
    Collins, M
    Stone, GW
    Moses, JW
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) : 995 - 998