PET/CT Image Artifacts Caused by the Arms

被引:8
作者
Sarikaya, Ismet [1 ]
Sarikaya, Ali [2 ]
机构
[1] Kuwait Univ, Fac Med, Dept Nucl Med, Safat, Kuwait
[2] Trakya Univ, Fac Med, Dept Nucl Med, Edirne, Turkey
关键词
PET/CT; artifacts; arms; truncation; cold artifacts; CT; RECOGNITION; EXTENSION; FIELD;
D O I
10.2967/jnmt.120.248641
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET/CT images are usually obtained in the arms-up position in patients with no head and neck pathology and in the arms-down position to image the head and neck area. The arms usually cause artifacts regardless of up or down positioning. These artifacts include beam hardening, scatter, truncation, and cold areas (cold artifacts) in obese or large patients; motion artifacts; implanted-metal-object artifacts; and artifacts related to radiotracer extravasation at the injection site. In this review article, we will discuss the mechanisms of these artifacts and suggest solutions to reduce or eliminate them, such as reviewing the non-attenuation-corrected PET images, performing extended-field-of-view reconstruction, not applying scatter correction, and using software to correct beam-hardening, scatter, and truncation artifacts. We will present various PET/CT images before and after corrections for such artifacts.
引用
收藏
页码:19 / 22
页数:4
相关论文
共 17 条
[1]  
[Anonymous], 2014, PET CT ATL QUAL CONT, V30, P41
[2]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[3]   PET/CT artifacts [J].
Blodgett, Todd M. ;
Mehta, Ajeet S. ;
Mehta, Amar S. ;
Laymon, Charles M. ;
Carney, Jonathan ;
Townsend, David W. .
CLINICAL IMAGING, 2011, 35 (01) :49-63
[4]  
Boas FE, 2012, Imaging Med, V4, P229, DOI 10.2217/iim.12.13
[5]   Scatter Limitation to Correct for Arm Movement in PET/CT [J].
Callahan, Jason ;
Binns, David ;
Deller, Timothy ;
Hicks, Rodney J. .
CLINICAL NUCLEAR MEDICINE, 2012, 37 (08) :786-787
[6]   Investigation of the halo-artifact in 68Ga-PSMA-11-PET/MRI [J].
Heusser, Thorsten ;
Mann, Philipp ;
Rank, Christopher M. ;
Schaefer, Martin ;
Dimitrakopoulou-Strauss, Antonia ;
Schlemmer, Heinz-Peter ;
Hadaschik, Boris A. ;
Kopka, Klaus ;
Bachert, Peter ;
Kachelriess, Marc ;
Freitag, Martin T. .
PLOS ONE, 2017, 12 (08)
[7]  
Kunze H, 2007, MED IMAGING 2007 PHY
[8]   Effect of Patient Arm Motion in Whole-Body PET/CT [J].
Lodge, Martin A. ;
Mhlanga, Joyce C. ;
Cho, Steve Y. ;
Wahl, Richard L. .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (12) :1891-1897
[9]   Truncation artifact on PET/CT: Impact on measurements of activity concentration and assessment of a correction algorithm [J].
Mawlawi, O ;
Erasmus, JJ ;
Pan, TS ;
Cody, DD ;
Campbell, R ;
Lonn, AH ;
Kohlmyer, S ;
Macapinlac, HA ;
Podoloff, DA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) :1458-1467
[10]   CT Artifact Recognition for the Nuclear Technologist [J].
Popilock, Robert ;
Sandrasagaren, Kumar ;
Harris, Lowell ;
Kaser, Keith A. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2008, 36 (02) :79-81