First in situ determination of the thermal performance of a U-pipe borehole heat exchanger, in Cyprus

被引:75
|
作者
Florides, Georglos [1 ]
Kalogirou, Soteris [1 ]
机构
[1] Higher Tech Inst, CY-2152 Nicosia, Cyprus
关键词
borehole; ground thermal conductivity; line source method;
D O I
10.1016/j.applthermaleng.2007.03.026
中图分类号
O414.1 [热力学];
学科分类号
摘要
A ground heat exchanger can be used for the injection or extraction of thermal energy into/from the ground. The line source model is an easy method of evaluating the characteristics of the borehole and does not need expensive equipment. This method is presented and a test is performed in order to determine a borehole's characteristics in layers consisting of clay, silt and sand at various analogies. For the borehole under test the ground thermal conductivity (lambda) was found to be 1.605 W/(m K) and the effective borehole thermal resistance (R-b) to be 0.257 K/(W/m). The accuracy of the collected data could be affected mainly by two factors. The first factor is the daily flux penetration through the ground which gradually increases the temperature of the top layers and the second factor is a variation of the heating coil injection rate per active length of borehole. As it was observed this combined effect has a negligible result on the mean fluid temperature during the test hours of 280-400, when the system was operating at steady state. The steady state conditions yield values of borehole thermal resistance which deviates about 25% from the values given by the line source method. The ground thermal conductivity deviates only about 5%. This method however is not suitable for estimating the above values because of the uncertainty that exists in the estimation of the mean ground temperature, which is not constant throughout the borehole length nor is it constant at different points in a cross section of the grout. Also this method takes a lot of time until the steady state is reached. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 50 条
  • [1] Evaluation of the impact of the thermal shunt effect on the U-pipe ground borehole heat exchanger performance
    Sandler, Stanislawa
    Zajaczkowski, Bartosz
    Bialko, Boguslaw
    Malecha, Ziemowit M.
    GEOTHERMICS, 2017, 65 : 244 - 254
  • [2] Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ
    Pahud, D
    Matthey, B
    ENERGY AND BUILDINGS, 2001, 33 (05) : 503 - 507
  • [3] Thermophysical and Heat Transfer Characteristics Based on Thermal Response and Thermal Recovery Test of a U-Pipe Borehole Heat Exchanger
    Li, P.
    Dou, B.
    Guan, P.
    Zheng, J.
    Tian, H.
    Duan, X.
    JOURNAL OF ENGINEERING THERMOPHYSICS, 2023, 32 (01) : 117 - 137
  • [4] Thermophysical and Heat Transfer Characteristics Based on Thermal Response and Thermal Recovery Test of a U-Pipe Borehole Heat Exchanger
    P. Li
    B. Dou
    P. Guan
    J. Zheng
    H. Tian
    X. Duan
    Journal of Engineering Thermophysics, 2023, 32 : 117 - 137
  • [5] Effect of depth and fluid flow rate on estimate for borehole thermal resistance of single U-pipe borehole heat exchanger
    Zhang, Changxing
    Wang, Xinjie
    Sun, Pengkun
    Kong, Xiangqiang
    Sun, Shicai
    RENEWABLE ENERGY, 2020, 147 : 2399 - 2408
  • [6] Sensitivity analysis on the performance of a ground source heat pump equipped with a double U-pipe borehole heat exchanger
    Casasso, Alessandro
    Sethi, Rajandrea
    EUROPEAN GEOSCIENCES UNION GENERAL ASSEMBLY 2014, EGU DIVISION ENERGY, RESOURCES & THE ENVIRONMENT (ERE), 2014, 59 : 301 - 308
  • [7] THE GROUND SOURCE HEAT PUMP: A SYSTEM ANALYSIS WITH A PARTICULAR FOCUS ON THE U-PIPE BOREHOLE HEAT EXCHANGER
    Madani, Hatef
    Acuna, Jose
    Claesson, Joachim
    Lundqvist, Per
    Palm, Bjorn
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 395 - 402
  • [8] A STUDY OF THE HEAT FLUX OF U-PIPE GROUND HEAT EXCHANGER
    Zhang, Changxing
    Hu, Songtao
    Liu, Guodan
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2226 - 2233
  • [9] Modelling of the borehole filling of double U-pipe heat exchangers
    Oppelt, Thomas
    Riehl, Ingo
    Gross, Ulrich
    GEOTHERMICS, 2010, 39 (03) : 270 - 276
  • [10] Comparative analysis of U-pipe location on the sizing of borehole heat exchangers
    Zhang, Linfeng
    Luo, Xiaowei
    Huang, Gongsheng
    Zhang, Quan
    APPLIED THERMAL ENGINEERING, 2019, 150 : 666 - 673