ZIF-67 derived cobalt-based nanomaterials for electrocatalysis and nonenzymatic detection of glucose: Difference between the calcination atmosphere of nitrogen and air

被引:39
作者
Shi, Libo [1 ]
Li, Yufei [1 ]
Cai, Xuan [1 ]
Zhao, Hongli [1 ]
Lan, Minbo [1 ]
机构
[1] East China Univ Sci & Technol, Sch Chem & Mol Engn, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
Metal-organic frameworks; Calcination atmosphere; Cobalt nanomaterials; Porous carbon matrix; Nonenzymatic glucose sensing; METAL-ORGANIC FRAMEWORKS; REDUCED GRAPHENE OXIDE; DRUG-DELIVERY; HYDROGEN-PEROXIDE; CARBON; NANOPARTICLES; ELECTRODE; CO3O4; SENSOR; FILM;
D O I
10.1016/j.jelechem.2017.06.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Calcination of metal-organic frameworks (MOFs) with designed condition is an efficient and flexible method to synthesize electrocatalysts with high activity toward various applications. In this work, we propose a facile calcination procedure under N-2 atmosphere utilizing zeolitic imidazolate framework-67 (ZIF-67) as the precursor to obtain cobalt nanoparticles-porous carbon composites (denoted as ZIF-N-2) for nonenzymatic glucose detection in alkaline media. At the same time, calcination of ZIF-67 under air atmosphere with the same temperature was also carried out. The resulting product (denoted as ZIF-Air) was used as a comparison when evaluating the electrochemical performance of ZIF-N-2. By means of a series of physicochemical and electrochemical characterizations, different calcination atmosphere show great effect on the properties of the resulting materials. ZIF-N-2 shows the specific morphology with Co nanoparticles loaded on the porous carbon matrix, with superior conductivity, mass activity, and electrochemical effective surface area to ZIF-Air. Based on these distinct parameters, nearly 10 times higher response of ZIF-N-2 is obtained toward glucose than that of ZIF-Air. The sensitivity of ZIF-N-2 is calculated to be 0.227 mA mM(-1) cm(-2) in the linear range of 0.1-1.1 mM, with LOD of 5.69 mu M. Finally, the nonenzymatic glucose sensing performance of ZIF-N-2 modified screen-printed carbon electrode including selectivity, long-term stability and reproducibility were also proved to be outstanding. This work demonstrates the calcination of MOFs under designed condition can be a promising method to obtain electrocatalysts for electrochemical sensing application.
引用
收藏
页码:512 / 518
页数:7
相关论文
共 46 条
[1]   An Amine-Functionalized MIL-53 Metal-Organic Framework with Large Separation Power for CO2 and CH4 [J].
Couck, Sarah ;
Denayer, Joeri F. M. ;
Baron, Gino V. ;
Remy, Tom ;
Gascon, Jorge ;
Kapteijn, Freek .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2009, 131 (18) :6326-+
[2]   Electrospun Co3O4 nanofibers for sensitive and selective glucose detection [J].
Ding, Yu ;
Wang, Ying ;
Su, Liang ;
Bellagamba, Michael ;
Zhang, Heng ;
Lei, Yu .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :542-548
[3]   MWCNT-supported phthalocyanine cobalt as air-breathing cathodic catalyst in glucose/O2 fuel cells [J].
Elouarzaki, Kamal ;
Haddad, Raoudha ;
Holzinger, Michael ;
Le Goff, Alan ;
Thery, Jessica ;
Cosnier, Serge .
JOURNAL OF POWER SOURCES, 2014, 255 :24-28
[4]   Synthesis of 3D hierarchical porous Co3O4 film by eggshell membrane for non-enzymatic glucose detection [J].
Fan, Sisi ;
Zhao, Minggang ;
Ding, Longjiang ;
Liang, Jingjing ;
Chen, Jing ;
Li, Yingchun ;
Chen, Shougang .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 775 :52-57
[5]   Metal-Organic Frameworks/Graphene Oxide Composite: A New Enzymatic Immobilization Carrier for Hydrogen Peroxide Biosensors [J].
Fan, Zengjie ;
Wang, Jinqing ;
Nie, Yingying ;
Ren, Liling ;
Liu, Bin ;
Liu, Gang .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (03) :B32-B37
[6]   Highly sensitive nonenzymatic glucose and H2O2 sensor based on Ni(OH)2/electroreduced graphene oxide-Multiwalled carbon nanotube film modified glass carbon electrode [J].
Gao, Wei ;
Tjiu, Weng Weei ;
Wei, Junchao ;
Liu, Tianxi .
TALANTA, 2014, 120 :484-490
[7]   Amperometric enzyme-free glucose sensor based on the use of a reduced graphene oxide paste electrode modified with electrodeposited cobalt oxide nanoparticles [J].
Heidari, Hassan ;
Habibi, Esmaeil .
MICROCHIMICA ACTA, 2016, 183 (07) :2259-2266
[8]   A novel electrochemical sensor based on metal-organic framework for electro-catalytic oxidation of L-cysteine [J].
Hosseini, Hadi ;
Ahmar, Hamid ;
Dehghani, Ali ;
Bagheri, Akbar ;
Tadjarodi, Azadeh ;
Fakhari, Ali Reza .
BIOSENSORS & BIOELECTRONICS, 2013, 42 :426-429
[9]   Metal-organic framework templated synthesis of Co3O4 nanoparticles for direct glucose and H2O2 detection [J].
Hou, Chuantao ;
Xu, Qin ;
Yin, Lina ;
Hu, Xiaoya .
ANALYST, 2012, 137 (24) :5803-5808
[10]   A highly sensitive nonenzymatic glucose sensor based on CuO nanoparticles-modified carbon nanotube electrode [J].
Jiang, Liao-Chuan ;
Zhang, Wei-De .
BIOSENSORS & BIOELECTRONICS, 2010, 25 (06) :1402-1407