Absence Seizure Detection Algorithm for Portable EEG Devices

被引:6
|
作者
Glaba, Pawel [1 ]
Latka, Miroslaw [1 ]
Krause, Malgorzata J. [2 ]
Kroczka, Slawomir [3 ]
Kurylo, Marta [2 ]
Kaczorowska-Frontczak, Magdalena [4 ]
Walas, Wojciech [5 ]
Jernajczyk, Wojciech [6 ]
Sebzda, Tadeusz [7 ]
West, Bruce J. [8 ]
机构
[1] Wroclaw Univ Sci & Technol, Dept Biomed Engn, Wroclaw, Poland
[2] T Marciniak Hosp, Dept Pediat Neurol, Wroclaw, Poland
[3] Jagiellonian Univ Med Coll, Dept Child Neurol, Krakow, Poland
[4] Childrens Mem Hlth Inst, Warsaw, Poland
[5] Univ Opole, Inst Med Sci, Paediat & Neonatal Intens Care Unit, Opole, Poland
[6] Inst Psychiat & Neurol, Clin Neurophysiol, Warsaw, Poland
[7] Wroclaw Med Univ, Dept Pathophysiol, Wroclaw, Poland
[8] Army Res Off, Off Director, Durham, NC USA
来源
FRONTIERS IN NEUROLOGY | 2021年 / 12卷
关键词
childhood absence epilepsy; EEG; wavelets; detector; portable device; EPILEPSY; CHILDHOOD; DISCHARGES; MODEL;
D O I
10.3389/fneur.2021.685814
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Absence seizures are generalized nonmotor epileptic seizures with abrupt onset and termination. Transient impairment of consciousness and spike-slow wave discharges (SWDs) in EEG are their characteristic manifestations. This type of seizure is severe in two common pediatric syndromes: childhood (CAE) and juvenile (JAE) absence epilepsy. The appearance of low-cost, portable EEG devices has paved the way for long-term, remote monitoring of CAE and JAE patients. The potential benefits of this kind of monitoring include facilitating diagnosis, personalized drug titration, and determining the duration of pharmacotherapy. Herein, we present a novel absence detection algorithm based on the properties of the complex Monet continuous wavelet transform of SWDs. We used a dataset containing EEGs from 64 patients (37 h of recordings with almost 400 seizures) and 30 age and sex-matched controls (9 h of recordings) for development and testing. For seizures lasting longer than 2 s, the detector, which analyzed two bipolar EEG channels (Fp1-T3 and Fp2-T4), achieved a sensitivity of 97.6% with 0.7/h detection rate. In the patients, all false detections were associated with epileptiform discharges, which did not yield clinical manifestations. When the duration threshold was raised to 3 s, the false detection rate fell to 0.5/h. The overlap of automatically detected seizures with the actual seizures was equal to similar to 96%. For EEG recordings sampled at 250 Hz, the one-channel processing speed for midrange smartphones running Android 10 (about 0.2 s per 1 min of EEG) was high enough for real-time seizure detection.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] EEG-based Absence Seizure Detection Methods
    Liang, Sheng-Fu
    Chang, Wan-Lin
    Chiueh, Herming
    2010 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS IJCNN 2010, 2010,
  • [2] Online EEG Seizure Detection and Localization
    Mansouri, Amirsalar
    Singh, Sanjay P.
    Sayood, Khalid
    ALGORITHMS, 2019, 12 (09)
  • [3] Epileptic Seizure Detection With a Reduced Montage: A Way Forward for Ambulatory EEG Devices
    Asif, Raheel
    Saleem, Sand
    Hassan, Syed Ali
    Alharbi, Soltan Abed
    Kamboh, Awais Mehmood
    IEEE ACCESS, 2020, 8 : 65880 - 65890
  • [4] The Prospects of Non-EEG Seizure Detection Devices in Dogs
    Bongers, Jos
    Gutierrez-Quintana, Rodrigo
    Stalin, Catherine Elizabeth
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [5] Automatic Detection Of Seizure Activity From EEG Recordings Of Genetic Rat Model Of Absence Epilepsy
    Ozmen, Besir
    Yavuz, Melis
    Carcak, Nihan
    Oglu, Medine Gulcebi Idriz
    Molnar, Zoltan
    Onat, Filiz
    Ciftci, Rifat Koray
    29TH IEEE CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS (SIU 2021), 2021,
  • [6] Fusion Algorithm for Imbalanced EEG Data Processing in Seizure Detection
    Jiang, Zhen
    Zhao, Wenshan
    SEIZURE-EUROPEAN JOURNAL OF EPILEPSY, 2021, 91 : 207 - 211
  • [7] Automatic absence seizure detection evaluating matching pursuit features of EEG signals
    Giannakaki, Katerina
    Giannakakis, Giorgos
    Vorgia, Pelagia
    Klados, Manousos A.
    Zervakis, Michalis
    2019 IEEE 19TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2019, : 886 - 889
  • [8] Hybrid Grasshopper Optimization Algorithm and Support Vector Machines for Automatic Seizure Detection in EEG Signals
    Hamad, Asmaa
    Houssein, Essam H.
    Hassanien, Aboul Ella
    Fahmy, Aly A.
    INTERNATIONAL CONFERENCE ON ADVANCED MACHINE LEARNING TECHNOLOGIES AND APPLICATIONS (AMLTA2018), 2018, 723 : 82 - 91
  • [9] Seizure Detection Devices
    Baumgartner, Christoph
    Baumgartner, Jakob
    Lang, Clemens
    Lisy, Tamara
    Koren, Johannes P.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (03)
  • [10] Computationally-Efficient Algorithm for Real-Time Absence Seizure Detection in Wearable Electroencephalography
    Dan, Jonathan
    Vandendriessche, Benjamin
    Van Paesschen, Wim
    Weckhuysen, Dorien
    Bertrand, Alexander