Effect of inlet design on the performance of storage-type domestic electrical water heaters

被引:39
作者
Hegazy, Adel A. [1 ]
机构
[1] Menia Univ, Fac Engn, Mech Power Engn & Energy Dept, Al Minya 61517, Egypt
关键词
electric water heaters; thermal stratification; thermal storage; hot water; energy conservation;
D O I
10.1016/j.apenergy.2006.09.014
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The effect of inlet design on the performance of storage-type domestic electrical water heaters (EWHs) was experimentally investigated for energy conservation. Three different side-inlet geometries; namely wedged, perforated, and slotted pipe-inlets; were tested using two 50 L capacity EWHs of aspect ratios 1 and 2 and two discharge rates 5 and 10 L/min. The three inlet designs are successful in promoting good thermal stratification inside the storage tanks of the EWHs. However, the degree of mixing produced by each design is found to have a significant impact on the performance. Thermal performance is quantified in terms of discharge efficiency, extraction efficiency, and fraction of heat recoverable. The results show an excellent performance for the slotted inlet. Although performance measures of perforated inlet are slightly less, the slotted inlet is attractive as it is simpler to manufacture and the extra cost associated with adopting it inside the existing EWH models is justified by the substantial savings in electricity and water consumptions, which ultimately concern the users. (C) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1338 / 1355
页数:18
相关论文
共 32 条
[1]   THEORETICAL AND EXPERIMENTAL STUDIES OF STRATIFIED THERMOCLINE STORAGE OF HOT WATER [J].
ABDOLY, MA ;
RAPP, D .
ENERGY CONVERSION AND MANAGEMENT, 1982, 22 (03) :275-285
[2]  
ABRAMS DW, 1998, ASHRAE T, V104, P1843
[3]   AN EXPERIMENTAL-STUDY OF A STRATIFIED THERMAL STORAGE UNDER VARIABLE INLET TEMPERATURE FOR DIFFERENT INLET DESIGNS [J].
ABUHAMDAN, MG ;
ZURIGAT, YH ;
GHAJAR, AJ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (08) :1927-1934
[4]  
[Anonymous], 1999, ASHRAE T
[5]   Measured and modeled charging of a stratified chilled water thermal storage tank with slotted pipe diffusers [J].
Bahnfleth, WP ;
Song, J ;
Cimbala, JM .
HVAC&R RESEARCH, 2003, 9 (04) :467-491
[6]  
COLLIVER DG, 1988, ASHRAE T, V94, P1110
[7]   The effect of tank geometry on thermally stratified sensible heat storage subject to low Reynolds number flows [J].
Eames, PC ;
Norton, B .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1998, 41 (14) :2131-2142
[8]   NUMERICAL STUDY OF THE EFFECT OF INLET GEOMETRY ON STRATIFICATION IN THERMAL-ENERGY STORAGE [J].
GHAJAR, AJ ;
ZURIGAT, YH .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 1991, 19 (01) :65-83
[9]   Performance of an improved design for storage-type domestic electrical water-heaters [J].
Hegazy, AA ;
Diab, MR .
APPLIED ENERGY, 2002, 71 (04) :287-306
[10]   A REVIEW OF LOW-FLOW, STRATIFIED-TANK SOLAR WATER HEATING-SYSTEMS [J].
HOLLANDS, KGT ;
LIGHTSTONE, MF .
SOLAR ENERGY, 1989, 43 (02) :97-105