Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice

被引:48
作者
Wu, MC
Gao, DW
Sievers, RE
Lee, RJ
Hasegawa, BH
Dae, MW
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Cardiovasc Res Inst, San Francisco, CA 94143 USA
关键词
D O I
10.1016/S0735-1097(03)00716-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES Although transgenic mice have emerged as powerful experimental models of cardiovascular disease, methods for in vivo phenotypic assessment and characterization remain limited, motivating the development of new instruments for biologic measurement. BACKGROUND We have developed a single-photon emission computed tomography system with a pinhole collimator (pinhole SPECT) for high-resolution cardiovascular imaging of mice. In this study, we describe a protocol for myocardial perfusion imaging of mice using technetium-99m (Tc-99m)-sestamibi and demonstrate the feasibility for measurement of perfusion defect size from pinhole SPECT images. METHODS Mice were anesthetized and injected with 370 MBq (10 mCi) of Tc-99m-sestamibi. Tomographic projection images were acquired by rotating each mouse in a vertical axis in front of a stationary clinical scintillation camera equipped with a pinhole collimator. BALB/c mice (n = 15) were imaged after the permanent ligation of the left anterior descending coronary artery. The resulting defect size was measured from circumferential profiles of short-axis images. After imaging, the hearts were excised and sectioned to obtain ultra-high resolution digital autoradiographs of Tc-99m-sestamibi, from which the actual infarct size was determined. RESULTS Reconstructed image quality was equivalent to that obtained for clinical myocardial perfusion imaging. Linear regression analysis produced a correlation coefficient of 0.83 (p < 0.001) between the measured and actual values of the defect size. CONCLUSIONS These results demonstrate that myocardial perfusion can be characterized qualitatively and quantitatively in mice using pinhole SPECT. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:576 / 582
页数:7
相关论文
共 26 条
[1]   Quantification of dopamine transporters in the mouse brain using ultra-high resolution single-photon emission tomography [J].
Acton, PD ;
Choi, SR ;
Plössl, K ;
Kung, HF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (05) :691-698
[2]   Occupancy of dopamine D2 receptors in the mouse brain measured using ultra-high-resolution single-photon emission tomography and [123I]IBF [J].
Acton, PD ;
Hou, C ;
Kung, MP ;
Plössl, K ;
Keeney, CL ;
Kung, HF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (11) :1507-1515
[3]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[4]  
GAYHEARTWALSTEN P, 1995, METHOD FIND EXP CLIN, V17, P249
[5]  
Habraken JBA, 2001, J NUCL MED, V42, P1863
[6]   Serial evaluation of fatty acid metabolism in rats with myocardial infarction by pinhole SPECT [J].
Hirai, T ;
Nohara, R ;
Ogoh, S ;
Chen, LG ;
Kataoka, A ;
Li, XH ;
Fujita, M ;
Matsumori, A ;
Taguchi, S ;
Sasayama, S .
JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (04) :472-481
[7]   Evaluation of myocardial infarct size in rat heart by pinhole SPECT [J].
Hirai, T ;
Nohara, R ;
Hosokawa, R ;
Tanaka, M ;
Inada, H ;
Fujibayashi, Y ;
Fujita, M ;
Konishi, J ;
Sasayama, S .
JOURNAL OF NUCLEAR CARDIOLOGY, 2000, 7 (02) :107-111
[8]   New approaches to phenotypic analysis in adult mice [J].
Hoit, BD .
JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2001, 33 (01) :27-35
[9]  
ISHIZU K, 1995, J NUCL MED, V36, P2282
[10]   PINHOLE COLLIMATION FOR ULTRA-HIGH-RESOLUTION, SMALL-FIELD-OF-VIEW SPECT [J].
JASZCZAK, RJ ;
LI, JY ;
WANG, HL ;
ZALUTSKY, MR ;
COLEMAN, RE .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :425-437