Turbulence influence on wind energy extraction for a medium size vertical axis wind turbine

被引:39
作者
Mollerstrom, Erik [1 ,2 ]
Ottermo, Fredric [1 ]
Goude, Anders [2 ]
Eriksson, Sandra [2 ]
Hylander, Jonny [1 ]
Bernhoff, Hans [2 ]
机构
[1] Halmstad Univ, Dept Construct & Energy Engn, POB 823, SE-30118 Halmstad, Sweden
[2] Uppsala Univ, Div Elect, Dept Engn Sci, POB 534, SE-75121 Uppsala, Sweden
关键词
VAWT; H-rotor; turbulence intensity; power coefficient curve; PERFORMANCE;
D O I
10.1002/we.1962
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The relation between power performance and turbulence intensity for a VAWT H-rotor is studied using logged data from a 14month (discontinuous) period with the H-rotor operating in wind speeds up to 9m/s. The turbine, designed originally for a nominal power of 200kW, operated during this period mostly in a restricted mode due to mechanical concerns, reaching power levels up to about 80kW. Two different approaches are used for presenting results, one that can be compared to power curves consistent with the International Electrotechnical Commission (IEC) standard and one that allows isolating the effect of turbulence from the cubic variation of power with wind speed. Accounting for this effect, the turbine still shows slightly higher efficiency at higher turbulence, proposing that the H-rotor is well suited for wind sites with turbulent winds. The operational data are also used to create a C-p() curve, showing slightly lower C-p compared with a curve simulated by a double multiple streamtube model. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:1963 / 1973
页数:11
相关论文
共 27 条
[1]  
[Anonymous], 2010, WIND ENERGY EXPLAINE
[2]  
[Anonymous], 1965, HOERNER FLUID DYNAMI
[3]  
Bertenyi T, 2010, 48 AIAA AER SCI M IN, P1376
[4]  
Darrieus G., 1931, TURBINE HAVING ITS R
[5]   Simulating Dynamic Stall Effects for Vertical Axis Wind Turbines Applying a Double Multiple Streamtube Model [J].
Dyachuk, Eduard ;
Goude, Anders .
ENERGIES, 2015, 8 (02) :1353-1372
[6]  
Eriksson S, 2011, 225KW DIRECT DRIVEN
[7]   Evaluation of different turbine concepts for wind power [J].
Eriksson, Sandra ;
Bernhoff, Hans ;
Leijon, Mats .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2008, 12 (05) :1419-1434
[8]   Tip speed ratio control of a 200 kW VAWT with synchronous generator and variable DC voltage [J].
Eriksson, Sandra ;
Kjellin, Jon ;
Bernhoff, Hans .
ENERGY SCIENCE & ENGINEERING, 2013, 1 (03) :135-143
[9]   How to improve the estimation of power curves for wind turbines [J].
Gottschall, Julia ;
Peinke, Joachim .
ENVIRONMENTAL RESEARCH LETTERS, 2008, 3 (01)
[10]  
Goude Anders., 2012, Fluid Mechanics of Vertical Axis Turbines: Simulations and Model Development