Fast diffusion-weighted steady state free precession imaging of in vivo knee cartilage

被引:18
|
作者
Bieri, O. [1 ]
Ganter, C. [2 ]
Welsch, G. H. [3 ]
Trattnig, S. [3 ]
Mamisch, T. C. [4 ]
Scheffler, K. [1 ]
机构
[1] Univ Basel Hosp, Dept Med Radiol, Div Radiol Phys, CH-4031 Basel, Switzerland
[2] Tech Univ Munich, Klinikum Rechts Isar, Inst Radiol, D-8000 Munich, Germany
[3] Med Univ Vienna, Dept Radiol, MR Ctr, Vienna, Austria
[4] Univ Bern, Inselspital, Dept Orthoped Surg, CH-3010 Bern, Switzerland
关键词
steady state; SSFP; diffusion; DWI; quantification; CE-FAST SEQUENCE; FIELD-GRADIENT; SPIN ECHOES; HUMAN-BRAIN; MAGNETIZATION; SENSITIVITY; ACQUISITION; MRI;
D O I
10.1002/mrm.23061
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantification of molecular diffusion with steady state free precession (SSFP) is complicated by the fact that diffusion effects accumulate over several repetition times (TR) leading to complex signal dependencies on transverse and longitudinal magnetization paths. This issue is commonly addressed by setting TR > T2, yielding strong attenuation of all higher modes, except of the shortest ones. As a result, signal attenuation from diffusion becomes T2 independent but signal-to-noise ratio (SNR) and sequence efficiency are remarkably poor. In this work, we present a new approach for fast in vivo steady state free precession diffusion-weighted imaging of cartilage with TR << T2 offering a considerable increase in signal-to-noise ratio and sequence efficiency. At a first glance, prominent coupling between magnetization paths seems to complicate quantification issues in this limit, however, it is observed that diffusion effects become rather T2(Delta D similar to 1/10 Delta T2) but not T1 independent (Delta D similar to 1/2 Delta T1) for low flip angles a similar to 10 - 15 degrees. As a result, fast high-resolution (0.35 x 0.35 - 0.50 x 0.50 mm2 in-plane resolution) quantitative diffusion-weighted imaging of human articular cartilage is demonstrated at 3.0 T in a clinical setup using estimated T1 and T2 or a combination of measured T1 and estimated T2 values. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:691 / 700
页数:10
相关论文
共 50 条
  • [21] Introduction to the basic principles and techniques of diffusion-weighted imaging
    Laun, F. B.
    Fritzsche, K. H.
    Kuder, T. A.
    Stieltjes, B.
    RADIOLOGE, 2011, 51 (03): : 170 - 179
  • [22] Comparison of free breathing and respiratory triggered diffusion-weighted imaging sequences for liver imaging
    Szklaruk, Janio
    Son, Jong Bum
    Wei, Wei
    Bhosale, Priya
    Javadi, Sanaz
    Ma, Jingfei
    WORLD JOURNAL OF RADIOLOGY, 2019, 11 (11):
  • [23] Optimization of a dual echo in the steady state (DESS) free-precession sequence for imaging cartilage
    Hardy, PA
    Recht, MP
    Piraino, D
    Thomasson, D
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (02): : 329 - 335
  • [24] Diagnostic value of synthetic diffusion-weighted imaging on breast magnetic resonance imaging assessment: comparison with conventional diffusion-weighted imaging
    Yilmaz, Ebru
    Guldogan, Nilgun
    Ulus, Sila
    Turk, Ebru Banu
    Misir, Mustafa Enes
    Arslan, Aydan
    Aribal, Mustafa Erkin
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (02): : 91 - 98
  • [25] HIGH-RESOLUTION RENAL DIFFUSION IMAGING USING A MODIFIED STEADY-STATE FREE PRECESSION SEQUENCE
    DING, SJ
    TRILLAUD, H
    YONGBI, M
    ROLETT, EL
    WEAVER, JB
    DUNN, JF
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (04) : 586 - 595
  • [26] Diffusion-weighted imaging and diffusion tensor imaging of the heart in vivo: major developments
    Mazur, Weronika
    Krzyzak, Artur T.
    Hennel, Franciszek
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2022, 18 (04): : 350 - 359
  • [27] Analytical Solution to the Transient Phase of Steady-State Free Precession Sequences
    Ganter, Carl
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 149 - 164
  • [28] 3D Steady-State Diffusion-Weighted Imaging With Trajectory Using Radially Batched Internal Navigator Echoes (TURBINE)
    McNab, Jennifer A.
    Gallichan, Daniel
    Miller, Karla L.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (01) : 235 - 242
  • [29] Dynamic and steady-state oxygen-dependent lung relaxometry using inversion recovery ultra-fast steady-state free precession imaging at 1.5 T
    Bauman, Grzegorz
    Pusterla, Orso
    Santini, Francesco
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 839 - 845
  • [30] Flow effects in balanced steady state free precession imaging
    Markl, M
    Alley, MT
    Elkins, CJ
    Pelc, NJ
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 892 - 903