Influence of Matrix Type on Surface Roughness of Three Resins for Provisional Crowns and Fixed Partial Dentures

被引:11
作者
Ayuso-Montero, Raul [1 ]
Martinez-Gomis, Jordi [1 ]
Lujan-Climent, Mar [1 ]
Salsench, Juan [1 ]
Peraire, Maria [1 ]
机构
[1] Univ Barcelona, Fac Dent, Dept Prosthodont, E-08907 Barcelona, Spain
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2009年 / 18卷 / 02期
关键词
Temporary crown; profilometry; matrix; fixed partial dentures;
D O I
10.1111/j.1532-849X.2008.00392.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study evaluated the effect of matrix type on the surface roughness of resins for provisional crowns and fixed partial dentures. Materials and Methods: Ninety specimens of two acrylic resins (Trim II, Tab2000) and one bis-acryl composite (Protemp II Garant) were fabricated using one of three matrices: irreversible hydrocolloid (Cavex CA37), poly(vinyl siloxane) (Aquasil) or vacuum-formed matrix (Bio-flow Hard). The sample size for each resin-matrix combination was 10. The vestibular face of one natural maxillary central incisor was used as a model to fabricate all the specimens, following the custom fabrication technique. The average roughness measurements, Ra (mu m), were obtained using a profilometer, and the data were analyzed using Kruskal-Wallis and Mann-Whitney U-tests. The results were contrasted against the surface roughness of the tooth using a one-sample t-test. Results: Aquasil and vacuum-formed matrix had a smoother surface than Cavex CA37 regardless of the resin tested (p < 0.05). Protemp II Garant had the smoothest surface regardless of the matrix used, with no significant differences when polymerized against the three different matrices. Trim II polymerized against Cavex CA37 had a rougher (p < 0.05) surface than Aquasil or vacuum-formed matrix. Tab2000 had the smoothest surface (p < 0.05) when polymerized against a vacuum-formed matrix. Conclusions: There is no universal matrix that produces the smoothest surface: this depends on the compatibility between the resin and the matrix. Protemp II Garant polymerized against Cavex CA37 matrix yields a surface that is smooth enough not to require polishing unless this surface is adjusted.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 21 条
[1]   Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature [J].
Bollen, CML ;
Lambrechts, P ;
Quirynen, M .
DENTAL MATERIALS, 1997, 13 (04) :258-269
[2]   Surface quality achieved by polishing and by varnishing of temporary crown and fixed partial denture resins [J].
Borchers, L ;
Tavassol, F ;
Tschernitschek, H .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (05) :550-556
[3]   A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: Report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics [J].
Burns, DR ;
Beck, DA ;
Nelson, SK .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (05) :474-497
[4]   Factors affecting the accuracy of elastometric impression materials [J].
Chen, SY ;
Liang, WM ;
Chen, FN .
JOURNAL OF DENTISTRY, 2004, 32 (08) :603-609
[5]  
Dunn WJ, 2004, OPER DENT, V29, P470
[6]  
Haselton Debra R, 2004, J Prosthodont, V13, P227
[7]   Flexural strength of provisional crown and fixed partial denture resins [J].
Haselton, DR ;
Diaz-Arnold, AM ;
Vargas, MA .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (02) :225-228
[8]  
Heintze SD, 2005, OPER DENT, V30, P617
[9]   Exotherm behavior of the polymer-based provisional crown and fixed partial denture materials [J].
Kim, SH ;
Watts, DC .
DENTAL MATERIALS, 2004, 20 (04) :383-387
[10]   Polymerization shrinkage-strain kinetics of temporary crown and bridge materials [J].
Kim, SH ;
Watts, DC .
DENTAL MATERIALS, 2004, 20 (01) :88-95