Real-Time Functional MRI Using Pseudo-Continuous Arterial Spin Labeling

被引:9
|
作者
Hernandez-Garcia, Luis [1 ,2 ]
Jahanian, Hesamoddin [2 ]
Greenwald, Mark K. [3 ]
Zubieta, Jon-Kar [4 ]
Peltier, Scott J. [1 ,2 ]
机构
[1] Univ Michigan, Funct MRI Lab, Ann Arbor, MI 48105 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48105 USA
[3] Wayne State Univ, Sch Med, Dept Psychiat & Neurosci, Detroit, MI USA
[4] Univ Michigan, Dept Psychiat, Ann Arbor, MI 48105 USA
关键词
arterial spin labeling; real time; fMRI; PERFUSION-BASED FMRI; CEREBRAL-BLOOD-FLOW; BRAIN ACTIVATION; DESIGN; BOLD; SENSITIVITY; MODEL; QUANTIFICATION; OPTIMIZATION; FEASIBILITY;
D O I
10.1002/mrm.22922
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The first implementation of real-time acquisition and analysis of arterial spin labeling-based functional magnetic resonance imaging time series is presented in this article. The implementation uses a pseudo-continuous labeling scheme followed by a spiral k-space acquisition trajectory. Real-time reconstruction of the images, preprocessing, and regression analysis of the functional magnetic resonance imaging data were implemented on a laptop computer interfaced with the MRI scanner. The method allows the user to track the current raw data, subtraction images, and the cumulative t-statistic map overlaid on a cumulative subtraction image. The user is also able to track the time course of individual time courses and interactively selects a region of interest as a nuisance covariate. The pulse sequence allows the user to adjust acquisition and labeling parameters while observing their effect on the image within two successive pulse repetition times. This method is demonstrated by two functional imaging experiments: a simultaneous finger-tapping and visual stimulation paradigm, and a bimanual finger-tapping task. Magn Reson Med 65:1570-1577, 2011. (C)2011 Wiley-Liss, Inc.
引用
收藏
页码:1570 / 1577
页数:8
相关论文
共 50 条
  • [1] AN EXPERIMENTAL INVESTIGATION OF LABELING EFFICIENCY FOR PSEUDO-CONTINUOUS ARTERIAL SPIN LABELING
    Chai, Yaqiong
    Bush, Adam
    Coloigner, Julie
    Qu, Xiaoping
    Chia, Jonathan
    Lepore, Natasha
    Wood, John
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1101 - 1104
  • [2] Pseudo-continuous arterial spin labeling MRI study of schizophrenic patients
    Ota, Miho
    Ishikawa, Masanori
    Sato, Noriko
    Okazaki, Mitsutoshi
    Maikusa, Norihide
    Hori, Hiroaki
    Hattori, Kotaro
    Teraishi, Toshiya
    Ito, Kimiteru
    Kunugi, Hiroshi
    SCHIZOPHRENIA RESEARCH, 2014, 154 (1-3) : 113 - 118
  • [3] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    van der Meer, Johan N.
    Heijtel, Dennis F. R.
    van Hest, Guus
    Plattel, Geert-Jan
    van Osch, Matthijs J. P.
    van Someren, Eus J. W.
    vanBavel, Ed T.
    Nederveen, Aart J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (03) : 269 - 276
  • [4] Superselective pseudo-continuous arterial spin labeling angiography
    Jensen-Kondering, Ulf
    Lindner, Thomas
    van Osch, Matthias J. P.
    Rohr, Axel
    Jansen, Olav
    Helle, Michael
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1758 - 1767
  • [5] A systematic study of the sensitivity of partial volume correction methods for the quantification of perfusion from pseudo-continuous arterial spin labeling MRI
    Zhao, Moss Y.
    Mezue, Melvin
    Segerdahl, Andrew R.
    Okell, Thomas W.
    Tracey, Irene
    Xiao, Yingyi
    Chappell, Michael A.
    NEUROIMAGE, 2017, 162 : 384 - 397
  • [6] Cerebral Blood Flow Quantification in Swine Using Pseudo-Continuous Arterial Spin Labeling
    Johnston, Megan E.
    Zheng, Zhenlin
    Maldjian, Joseph A.
    Whitlow, Christopher T.
    Morykwas, Michael J.
    Jung, Youngkyoo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (05) : 1111 - 1118
  • [7] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    Johan N. van der Meer
    Dennis F. R. Heijtel
    Guus van Hest
    Geert-Jan Plattèl
    Matthijs J. P. van Osch
    Eus J. W. van Someren
    Ed T. vanBavel
    Aart J. Nederveen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 269 - 276
  • [8] Improved Pseudo-Continuous Arterial Spin Labeling for Mapping Brain Perfusion
    Nezamzadeh, Marzieh
    Matson, Gerald B.
    Young, Karl
    Weiner, Michael W.
    Schuff, Norbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (06) : 1419 - 1427
  • [9] Cardiac-triggered pseudo-continuous arterial-spin-labeling: A cost-effective scheme to further enhance the reliability of arterial-spin-labeling MRI
    Li, Yang
    Mao, Deng
    Li, Zhiqiang
    Schaer, Michael
    Pillai, Jay J.
    Pipe, James G.
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) : 969 - 975
  • [10] Simultaneous measurement of brain perfusion and labeling efficiency in a single pseudo-continuous arterial spin labeling scan
    Chen, Zhensen
    Zhao, Xihai
    Zhang, Xingxing
    Guo, Rui
    Teeuwisse, Wouter M.
    Zhang, Bida
    Koken, Peter
    Smink, Jouke
    Yuan, Chun
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 1922 - 1930