Structural adaptations in compressed articular cartilage measured by diffusion tensor imaging

被引:55
作者
de Visser, S. K. [1 ,2 ]
Crawford, R. W. [2 ]
Pope, J. M. [1 ,2 ]
机构
[1] Queensland Univ Technol, Sch Phys & Chem Sci, Brisbane, Qld 4001, Australia
[2] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Brisbane, Qld 4001, Australia
关键词
articular cartilage; MRI; diffusion tensor imaging; compression; collagen; osteoarthritis;
D O I
10.1016/j.joca.2007.05.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To demonstrate the use of diffusion tensor magnetic resonance micro-imaging to observe adaptations of Collagen fibres to mechanical compression in articular cartilage. Methods: Spin-echo and diffusion tensor images (156 x 156 gm in-plane resolution, 2 mm slice thickness) of bovine cartilage were obtained at a magnetic field of 7.0 T in relaxed and compressed states. The parameters determined were: T-2, maximum and mean diffusivity, direction of the maximum diffusion eigenvector and fractional anisotropy of diffusion. Results: A correlation was found between the compressive strain applied to the cartilage and the change in both magnitude and direction of the maximum diffusivity. Compression resulted in a decrease in both the maximum and mean eigenvalues, particularly in the surface and transitional zones, while the change in orientation of the eigenvectors corresponding to maximum diffusion was greatest in the transitional region. In this region, the average orientation of the principal eigenvectors with respect to the normal to the articular surface increased by up to 40 degrees, indicating that the collagen fibre bundles were oriented more parallel to the surface when compressed. Conclusions: Diffusion tensor imaging can be used to monitor the changes in the direction of the collagen fibres due to compression. It may form the basis of a new non-invasive approach to functional evaluation of cartilage, with potential applications in the diagnosis and treatment of osteoarthritis. (c) 2007 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 22 条
  • [1] The structural adaptations in compressed articular cartilage by microscopic MRI (μMRI) T2 anisotropy
    Alhadlaq, HA
    Xia, Y
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2004, 12 (11) : 887 - 894
  • [2] Benninghoff, 1925, Z ZELLFORSCH, V2, P783, DOI [DOI 10.1007/BF00583443, 10.1007/BF00583443]
  • [3] High-resolution diffusion tensor imaging of human patellar cartilage: Feasibility and preliminary findings
    Filidoro, L
    Dietrich, O
    Weber, J
    Rauch, E
    Oerther, T
    Wick, M
    Reiser, MF
    Glaser, C
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 993 - 998
  • [4] Functional anatomy of articular cartilage under compressive loading quantitative aspects of global, local and zonal reactions of the collagenous network with respect to the surface integrity
    Glaser, C
    Putz, R
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (02) : 83 - 99
  • [5] 3-DIMENSIONAL COLLAGEN ARCHITECTURE IN BOVINE ARTICULAR-CARTILAGE
    JEFFERY, AK
    BLUNN, GW
    ARCHER, CW
    BENTLEY, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05): : 795 - 801
  • [6] Deformation of articular cartilage collagen structure under static and cyclic loading
    Kääb, MJ
    Ito, K
    Clark, JM
    Nötzli, HP
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (06) : 743 - 751
  • [7] The acute structural changes of loaded articular cartilage following meniscectomy or ACL-transection
    Kääb, MJ
    Ito, K
    Clark, JM
    Nötzli, HP
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2000, 8 (06) : 464 - 473
  • [8] Effect of mechanical load on articular cartilage collagen structure:: A scanning electron-microscopic study
    Kääb, MJ
    Ito, K
    Rahn, B
    Clark, JM
    Nötzli, HP
    [J]. CELLS TISSUES ORGANS, 2000, 167 (2-3) : 106 - 120
  • [9] Electron microscopic stereological study of collagen fibrils in bovine articular cartilage:: volume and surface densities are best obtained indirectly (from length densities and diameters) using isotropic uniform random sampling
    Långsjö, TK
    Hyttinen, M
    Pelttari, A
    Kiraly, K
    Arokoski, J
    Helminen, HJ
    [J]. JOURNAL OF ANATOMY, 1999, 195 : 281 - 293
  • [10] Diffusion tensor imaging: Concepts and applications
    Le Bihan, D
    Mangin, JF
    Poupon, C
    Clark, CA
    Pappata, S
    Molko, N
    Chabriat, H
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (04) : 534 - 546