Implementing Ozone-BAC-GAC in potable reuse for removal of emerging contaminants

被引:8
作者
Vaidya, Ramola [1 ]
Wilson, Christopher A. [2 ]
Salazar-Benites, Germano [2 ]
Pruden, Amy [1 ]
Bott, Charles [2 ]
机构
[1] Virginia Tech, Civil & Environm Engn Dept, Blacksburg, VA 24061 USA
[2] Hampton Rd Sanitat Dist, Virginia Beach, VA USA
来源
AWWA WATER SCIENCE | 2020年 / 2卷 / 05期
关键词
biologically activated carbon; contaminants of emerging concern; granular activated carbon; ozone; potable reuse; ACTIVATED CARBON; WASTE-WATER; MICROPOLLUTANTS; OZONATION; BIOFILTRATION; ADSORPTION; BIODEGRADATION; ELIMINATION; DESORPTION;
D O I
10.1002/aws2.1203
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Removal of contaminants of emerging concern (CECs) is an important consideration in potable reuse. The effectiveness of ozonation, biologically activated carbon (BAC) filtration, and granular activated carbon (GAC) adsorption was assessed in the removal of 96 CECs. During phase 1, O3/total organice carbon (TOC) was varied between 0 and 1.5. Ozone was successful in removing CECs, achieving a total CEC concentration of 20.5 mu g/L at an O3/TOC of 1.5 compared with 70 mu g/L in absence of ozone. CECs such as iohexol, meprobamate, sucralose and flame retardants, tris(2-carboxyethyl)phosphine (TCEP), tris(1-chloro-2-propyl) phosphate (TCPP), and tris(1,3-dichloro-2-propyl)phosphate (TDCPP) were detected in the ozone effluent even at the highest ozone dose. BAC filters did not contribute measurably to CEC removal, while the 20-min empty bed contact time (EBCT) GAC removed 57.6% of the influent CEC concentration, even though the adsorption capacity had been exerted through previous operation. During phase 2, the average O3/TOC ratio was 0.64, and the impact of new GAC media on CEC removal was studied. EBCT was maintained at 15 min for both GAC contactors, while the used GAC (133,600 bed volume [BV]) was replaced with new media in one GAC contactor. The GAC with new media removed CECs below the limit of quantitation, up to 10,000 BV, while removal decreased to 70% after 20,000 BV, with seven CECs-sucralose, iohexol, acesulfame-k, meprobamate, cotinine, primidone, and acetaminophen-being detected. Ozone doses for CEC removal and BV needed for adsorption of CECs on activated carbon can be determined from this study. Thus, the results from this study can help design and optimize ozone, BAC, and GAC systems used for potable reuse to target the removal of specific CECs.
引用
收藏
页数:10
相关论文
共 29 条
[1]   Biodegradation of persistent organics can overcome adsorption-desorption hysteresis in biological activated carbon systems [J].
Abromaitis, V. ;
Racys, V. ;
van der Marel, P. ;
Meulepas, R. J. W. .
CHEMOSPHERE, 2016, 149 :183-189
[2]   Ozone oxidation of pharmaceuticals, endocrine disruptors and pesticides during drinking water treatment [J].
Broseus, R. ;
Vincent, S. ;
Aboulfadl, K. ;
Daneshvar, A. ;
Sauve, S. ;
Barbeau, B. ;
Prevost, M. .
WATER RESEARCH, 2009, 43 (18) :4707-4717
[3]   Enhanced bromate control during ozonation: The chlorine-ammonia process [J].
Buffle, MO ;
Galli, S ;
von Gunten, U .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (19) :5187-5195
[4]   Assessment of the origin and transport of four selected emerging micropollutants sucralose, Acesulfame-K, gemfibrozil, and iohexol in a karst spring during a multi-event spring response [J].
Doummar, Joanna ;
Aoun, Michel .
JOURNAL OF CONTAMINANT HYDROLOGY, 2018, 215 :11-20
[5]   Development of surrogate correlation models to predict trace organic contaminant oxidation and microbial inactivation during ozonation [J].
Gerrity, Daniel ;
Gamage, Sujanie ;
Jones, Darryl ;
Korshin, Gregory V. ;
Lee, Yunho ;
Pisarenko, Aleksey ;
Trenholm, Rebecca A. ;
von Gunten, Urs ;
Wert, Eric C. ;
Snyder, Shane A. .
WATER RESEARCH, 2012, 46 (19) :6257-6272
[6]   Optimizing Ozone-Biofiltration Systems for Organic Carbon Removal in Potable Reuse Applications [J].
Gifford, Mac ;
Selvy, Ashley ;
Gerrity, Daniel .
OZONE-SCIENCE & ENGINEERING, 2018, 40 (06) :427-440
[7]   Investigation of biotransformation, sorption, and desorption of multiple chemical contaminants in pilot-scale drinking water biofilters [J].
Greenstein, Katherine E. ;
Lew, Julia ;
Dickenson, Eric R. V. ;
Wert, Eric C. .
CHEMOSPHERE, 2018, 200 :248-256
[8]   Emerging Contaminant Removal by Biofiltration: Temperature, Concentration, and EBCT Impacts [J].
Halle, Cynthia ;
Huck, Peter M. ;
Peldszus, Sigrid .
JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2015, 107 (07) :E364-E379
[9]   Pilot testing of direct and indirect potable water reuse using multi- stage ozone-biofiltration without reverse osmosis [J].
Hooper, Jennifer ;
Funk, Denise ;
Bell, Kati ;
Noibi, Morayo ;
Vickstrom, Kyle ;
Schulz, Chris ;
Machek, Eddie ;
Huang, Ching-Hua .
WATER RESEARCH, 2020, 169
[10]   Kinetics and model development of iohexol degradation during UV/H2O2 and UV/S2O82- oxidation [J].
Hu, Chen-Yan ;
Hou, Yuan-Zhang ;
Lin, Yi-Li ;
Deng, Yan-Guo ;
Hua, Shuang-Jing ;
Du, Yi-Fan ;
Chen, Chiu-Wen ;
Wu, Chung-Hsin .
CHEMOSPHERE, 2019, 229 :602-610