An Experimental Study of a 3D Bone Position Estimation System Based on Fluoroscopic Images

被引:4
|
作者
Yoshii, Yuichi [1 ]
Iwahashi, Yuta [2 ]
Sashida, Satoshi [2 ]
Shrestha, Pragyan [3 ]
Shishido, Hidehiko [3 ]
Kitahara, Itaru [3 ]
Ishii, Tomoo [1 ]
机构
[1] Tokyo Med Univ, Ibaraki Med Ctr, Dept Orthoped Surg, Ami, Ibaraki 3000398, Japan
[2] LEXI Co Ltd, Sugamo, Tokyo 1700002, Japan
[3] Tsukuba Univ, Ctr Computat Sci, Tsukuba, Ibaraki 3058577, Japan
关键词
three-dimensional; tracking; computed tomography; fluoroscopy; preoperative plan; distal radius fracture; RECONSTRUCTION; SINGLE; OSTEOSYNTHESIS; REGISTRATION; ACCURACY; SPINE; CT;
D O I
10.3390/diagnostics12092237
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To compare a 3D preoperative planning image and fluoroscopic image, a 3D bone position estimation system that displays 3D images in response to changes in the position of fluoroscopic images was developed. The objective of the present study was to evaluate the accuracy of the estimated position of 3D bone images with reference to fluoroscopic images. Bone positions were estimated from reference points on a fluoroscopic image compared with those on a 3D image. The four reference markers positional relationships on the fluoroscopic image were compared with those on the 3D image to evaluate whether a 3D image may be drawn by tracking positional changes in the radius model. Intra-class correlations coefficients for reference marker distances between the fluoroscopic image and 3D image were 0.98-0.99. Average differences between measured values on the fluoroscopic image and 3D bone image for each marker corresponding to the direction of the bone model were 1.1 +/- 0.7 mm, 2.4 +/- 1.8 mm, 1.4 +/- 0.8 mm, and 2.0 +/- 1.6 mm in the anterior-posterior view, ulnar side lateral view, posterior-anterior view, and radial side lateral view, respectively. Marker positions were more accurate in the anterior-posterior and posterior-anterior views than in the radial and ulnar side lateral views. This system helps in real-time comparison of dynamic changes in preoperative 3D and intraoperative fluoroscopy images.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A 3D kinematic estimation of knee prosthesis from fluoroscopic images
    Hossain, Mohammad Abrar
    Ikebe, Norihiro
    Kihara, Yuichi
    Hirokawa, Shunji
    PROCEEDINGS OF THE FIFTH IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2007, : 125 - +
  • [2] Estimation of 3D Fluoroscopic Treatment Images Using a Single Cine EPID Image
    Mishra, P.
    Li, R.
    Williams, C.
    Berbeco, R.
    Lewis, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] 3D reconstruction and navigated removal of femoral bone cement in revision THR based on few fluoroscopic images
    de la Fuente, M
    Schkommodau, E
    Lutz, P
    Neuss, M
    Wirtz, DC
    Radermacher, K
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 626 - 631
  • [4] Improvement of Position Estimation of the Ultrasonic 3D Tag System
    Hori, Toshio
    Nishida, Yoshifumi
    2008 17TH IEEE INTERNATIONAL SYMPOSIUM ON ROBOT AND HUMAN INTERACTIVE COMMUNICATION, VOLS 1 AND 2, 2008, : 436 - 441
  • [5] Fluoroscopic 3D Images Based on 2D Treatment Images Using a Realistic Modified XCAT Phantom
    Lewis, J.
    Li, R.
    St James, S.
    Yue, Y.
    Berbeco, R.
    Mishra, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S737 - S737
  • [6] Model based estimation of camera position in 3D scene
    Pełczyński P.
    Advances in Intelligent and Soft Computing, 2011, 102 : 183 - 190
  • [7] Object 3D position estimation based on instance segmentation
    Liu Chang-ji
    Hao Zhi-cheng
    Yang Jin-cheng
    Zhu Ming
    Nie Hai-tao
    CHINESE JOURNAL OF LIQUID CRYSTALS AND DISPLAYS, 2021, 36 (11) : 1535 - 1544
  • [8] Towards 2D/3D Registration of the Preoperative MRI to Intraoperative Fluoroscopic Images for Visualisation or Bone Defects
    Ku, Ping-Cheng
    Martin-Gomez, Alejandro
    Gao, Cong
    Grupp, Robert
    Mears, Simon C.
    Armand, Mehran
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (04): : 1096 - 1105
  • [9] An iterative kalman filter for a 3D ultrasonic position estimation system
    Chitikeshi, Sanjeevi
    Mahajan, Ajay
    Akers, Jennifer
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINERING CONGRESS AND EXPOSITION 2007, VOL 9, PTS A-C: MECHANICAL SYSTEMS AND CONTROL, 2008, : 677 - 685
  • [10] Generation of fluoroscopic 3D images with a respiratory motion model based on an external surrogate signal
    Hurwitz, Martina
    Williams, Christopher L.
    Mishra, Pankaj
    Rottmann, Joerg
    Dhou, Salam
    Wagar, Matthew
    Mannarino, Edward G.
    Mak, Raymond H.
    Lewis, John H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02): : 521 - 535