Experimental study of mass transfer and H2S removal efficiency in a spray tower

被引:32
|
作者
Turpin, A. [1 ]
Couvert, A. [1 ]
Laplanche, A. [1 ]
Paillier, A. [2 ]
机构
[1] Ecole Natl Super Chim Rennes, UMR 6226, CNRS, CIP, F-35700 Rennes, France
[2] ADEME, F-49000 Angers, France
关键词
spray tower; absorption; mass transfer; deodorisation;
D O I
10.1016/j.cep.2007.02.002
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The aim of this study was to characterise the mass transfer parameters and H2S removal efficiency in a laboratory-made spray tower designed for deodorisation. In order to study mass transfer, the volumic interfacial area (a) and the volumic mass transfer coefficient (k(L)a) were estimated. The influences of both superficial liquid and gas velocities were quantified (U-L from 4.1 X 10(-5) to 4.6 x 10(-4) m s(-1), U-G from 9.4 x 10(-3) to 2.8 x 10(-2) m s(-1)). It could be shown that the superficial liquid velocity has a slight influence on the mass transfer parameters whereas the variation of the superficial gas velocity influences them much more. Then H2S removal efficiency was studied at pH 10 in the presence or not of an oxidant, sodium hypochlorite. The results demonstrated that as soon as the chlorination rate reached 0.5 g Cl-2 L-1, more than 99% of the hydrogen sulphide is removed. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
  • [1] Experimental study of the SO2 removal efficiency and volumetric mass transfer coefficients in a pilot-scale multi-nozzle spray tower
    Codolo, Milene C.
    Bizzo, Waldir A.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 66 : 80 - 89
  • [2] Experimental evaluation and neural networks modeling of removal efficiency and volumetric mass transfer coefficient for gas desulfurization in spray tower
    Valera, Vinicius Y.
    Martins, Tiago D.
    Codolo, Milene C.
    CHEMICAL ENGINEERING SCIENCE, 2024, 285
  • [3] SO2 removal by seawater in a spray tower: Experimental study and mathematical modeling
    Darake, Sh.
    Hatamipour, M. S.
    Rahimi, A.
    Hamzeloui, P.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 109 : 180 - 189
  • [4] Experimental Study on Removal of H2S using MDEA Solution in Microchannel
    Ji, Huali
    Zhang, Yanhong
    Wei, Chenwen
    Wang, Hualin
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2016), 2016, 98 : 178 - 185
  • [5] MASS TRANSFER AND DEODORIZATION EFFICIENCY IN A COUNTERCURRENT SPRAY TOWER FOR LOW SUPERFICIAL GAS VELOCITIES
    Turpin, A.
    Couvert, A.
    Laplanche, A.
    Paillier, A.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2009, 87 (01) : 53 - 59
  • [6] Experimental optimization of a spray tower for ammonia removal
    Jafari, Mohammad Javad
    Matin, Amir Hossein
    Rahmati, Alireza
    Azari, Mansour Rezazadeh
    Omidi, Leila
    Hosseini, Seyed Saeed
    Panahi, Davood
    ATMOSPHERIC POLLUTION RESEARCH, 2018, 9 (04) : 783 - 790
  • [7] Artificial neural network for prediction of SO2 removal and volumetric mass transfer coefficient in spray tower
    Valera, Vinicius Y.
    Codolo, Milene C.
    Martins, Tiago D.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2021, 170 : 1 - 12
  • [8] Mass transfer in a spray column for CO2 removal
    Kuntz, Jeff
    Aroonwilas, Adisorn
    2006 IEEE EIC CLIMATE CHANGE CONFERENCE, VOLS 1 AND 2, 2006, : 399 - +
  • [9] SIMULTANEOUS HEAT AND MASS-TRANSFER MODEL FOR SPRAY TOWER DESIGN - APPLICATION ON VOCS REMOVAL
    MEYER, M
    HENDOU, M
    PREVOST, M
    COMPUTERS & CHEMICAL ENGINEERING, 1995, 19 : S277 - S282
  • [10] Research on mass transfer of CO2 absorption using ammonia solution in spray tower
    Ma, Shuangchen
    Zang, Bin
    Song, Huihui
    Chen, Gongda
    Yang, Jiehong
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 67 : 696 - 703