Agreement of total corneal power between 2 swept-source optical coherence tomography and Scheimpflug tomography in normal and keratoconic patients

被引:17
作者
Asawaworarit, Rosepon [1 ]
Satitpitakul, Vannarut [1 ]
Taweekitikul, Parichart [1 ]
Pongpirui, Krit [2 ]
机构
[1] Chulalongkorn Univ, King Chulalongkorn Mem Hosp, Excellence Ctr Cornea & Limbal Stem Cell Transpla, Fac Med,Dept Ophthalmol, Bangkok, Thailand
[2] Chulalongkorn Univ, Fac Med, Bangkok, Thailand
关键词
REPEATABILITY; ASTIGMATISM; EYES; RELIABILITY; KERATOMETRY;
D O I
10.1371/journal.pone.0268856
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To evaluate agreement of total corneal power (TCP) measured by swept-source anterior segment optical coherence tomography (CASIA 2), Scheimpflug tomography (Pentacam AXL), and swept-source optical biometer (IOLMaster 700) in normal and keratoconic patients. Methods This is a prospective observational study conducted at King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Biometric values were measured by each device for three times by two operators to evaluate repeatability and reproducibility of TCP. The agreement of TCP and other parameters including total corneal astigmatism, anterior keratometry, anterior corneal astigmatism, posterior keratometry, posterior corneal astigmatism, anterior chamber depth, white-to-white corneal diameter (WTW), central corneal thickness, and intraocular power were also evaluated. Results This study enrolled 100 healthy participants and 34 patients with keratoconus. The repeatability and reproducibility of TCP were high in all devices (ICC > 0.9). The agreement of TCP was excellent among three devices in both groups (ICC > 0.9). However, the agreement of TCP between CASIA 2 and IOLMaster 700 was slightly lower in healthy participants (ICC = 0.867) and keratoconic patients (ICC = 0.852) with mean differences of more than 1.0 diopter is clinically significant. Wider 95% limit of agreement were found in keratoconic eyes. Most of other parameters showed good to excellent agreement except WTW which showed poor to moderate agreement in both groups. IOL power showed clinically significant differences in patients with keratoconus. Conclusions The agreement of TCP measured by three devices was excellent in normal and keratoconic patients. However, TCP cannot be used interchangeably between devices.
引用
收藏
页数:14
相关论文
共 27 条
[1]  
Bland JM, 1996, BRIT MED J, V313, P744
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Statistics notes: Measurement error proportional to the mean .23. [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7049) :106-106
[4]   Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lenses [J].
Fam, Han Bor ;
Lim, Kooi Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2072-2076
[5]   Mean Posterior Corneal Power and Astigmatism in Normal Versus Keratoconic Eyes [J].
Feizi, Sepehr ;
Delfazayebaher, Siamak ;
Javadi, Mohammad Ali ;
Karimian, Farid ;
Ownagh, Vahid ;
Sadeghpour, Fatemeh .
JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (02) :93-100
[6]   Intraocular lens power calculation in eyes with keratoconus [J].
Garzon, Nuria ;
Arriola-Villalobos, Pedro ;
Felipe, Gema ;
Poyales, Francisco ;
Garcia-Montero, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05) :778-783
[7]   Repeatability and reproducibility of Galilei measurements in normal keratoconic and postrefractive corneas [J].
Guler, Emre ;
Yagci, Ramazan ;
Akyol, Mesut ;
Arslanyilmaz, Zeynel ;
Balci, Mehmet ;
Hepsen, Ibrahim F. .
CONTACT LENS & ANTERIOR EYE, 2014, 37 (05) :331-336
[8]   Effect of keratoconus grades on repeatability of keratometry readings: Comparison of 5 devices [J].
Hashemi, Hassan ;
Yekta, Abbasali ;
Khabazkhoob, Mehdi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) :1065-1072
[9]   Contribution of posterior corneal astigmatism to total corneal astigmatism [J].
Koch, Douglas D. ;
Ali, Shazia F. ;
Weikert, Mitchell P. ;
Shirayama, Mariko ;
Jenkins, Richard ;
Wang, Li .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (12) :2080-2087
[10]   A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J].
Koo, Terry K. ;
Li, Mae Y. .
JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) :155-163