Robot-Assisted Total Hip Arthroplasty for Arthrodesed Hips

被引:11
|
作者
Chai, Wei [1 ]
Kong, Xiangpeng [1 ]
Yang, Minzhi [1 ,2 ]
Puah, Ken Lee [3 ]
Tang, Peifu [1 ]
Chen, Jiying [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Orthoped, Beijing, Peoples R China
[2] Nankai Univ, Med Coll, Tianjin, Peoples R China
[3] Singapore Gen Hosp, Dept Orthoped Surg, Singapore, Singapore
关键词
total hip arthroplasty; robot-assisted surgery; cup positioning; hip arthrodesis; ACETABULAR CUP PLACEMENT; ANKYLOSING-SPONDYLITIS; PLAIN ANTEROPOSTERIOR; COMPONENT; RELIABILITY; REPLACEMENT; PRECISION; VALIDITY; PATIENT;
D O I
10.2147/TCRM.S246565
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Conversion of arthrodesed hips to total hip arthroplasty (THA) remains technically demanding. This study aims to evaluate the safety and efficacy of robotassisted THA in arthrodesed hips. Methods: We retrospectively analyzed 45 ankylosing spondylitis patients with hip arthrodesis in the Chinese PLA General Hospital between August 2018 and August 2019. All surgeries were carried out by one single surgeon. The patients were followed at 3 months after surgery. Gender, body mass index, angle of hip arthrodesis, operating time, intraoperative fluoroscopic times, postoperative length of hospitalization, cup positioning, postoperative leg length discrepancy, offset discrepancy, intraoperative and postoperative complications, and postoperative Harris Hip Score were collected for all patients. Results: Twenty-two patients (35 hips) who underwent robot-assisted THA and 23 patients (37 hips) who underwent manual THA were enrolled in this study. There were no significant differences in demographics and arthrodesed angles between the two groups. The fluoroscopic times during manual THA were significantly higher than those during robot-assisted THA (2.16 +/- 1.61 vs 0.47 +/- 0.61, respectively, p=0.000). In the robotic group, the percentage of acetabular cups within the safe zone was significantly greater than in the manual group (94.29% vs 67.56%, respectively, p=0.042). For manual THA, the anteversions were significantly different between the left and right sides (21.14 +/- 7.86 vs 16.00 +/- 6.32, respectively, p=0.042); however, no such significant difference was found in robot-assisted THA. Conclusion: Compared with manual THA for arthrodesed hips, robot-assisted THA had significant advantages in improving the frequency of achieving cup positioning within the target zone with diminished radiation dose and no increase in operating time.
引用
收藏
页码:357 / 368
页数:12
相关论文
共 50 条
  • [1] Robot-assisted total hip arthroplasty
    Banerjee, Samik
    Cherian, Jeffery J.
    Elmallah, Randa K.
    Pierce, Todd P.
    Jauregui, Julio J.
    Mont, Michael A.
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (01) : 47 - 56
  • [2] Impact of surgeon handedness in manual and robot-assisted total hip arthroplasty
    Kong, Xiangpeng
    Yang, Minzhi
    Li, Xiang
    Ni, Ming
    Zhang, Guoqiang
    Chen, Jiying
    Chai, Wei
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [3] Robot-assisted total hip arthroplasty: Clinical outcomes and complication rate
    Perets, Itay
    Walsh, John P.
    Close, Mary R.
    Mu, Brian H.
    Yuen, Leslie C.
    Domb, Benjamin G.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (04)
  • [4] Does haptic robot-assisted total hip arthroplasty better restore native acetabular and femoral anatomy?
    Tsai, Tsung-Yuan
    Dimitriou, Dimitris
    Li, Jing-Sheng
    Kwon, Young-Min
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2016, 12 (02) : 288 - 295
  • [5] Impact of surgeon handedness in manual and robot-assisted total hip arthroplasty
    Xiangpeng Kong
    Minzhi Yang
    Xiang Li
    Ming Ni
    Guoqiang Zhang
    Jiying Chen
    Wei Chai
    Journal of Orthopaedic Surgery and Research, 15
  • [6] Radiographic evaluation of robot-assisted versus manual total hip arthroplasty: a multicenter randomized controlled trial
    Zhang, Xianzuo
    Shen, Xianyue
    Zhang, Rongwei
    Chen, Mo
    Ma, Ruixiang
    Zhang, Zian
    Zhang, Haining
    Yang, Bo
    Zhu, Chen
    JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY, 2024, 25 (01)
  • [7] Patient-reported outcome differences for navigated and robot-assisted total hip arthroplasty frequently do not achieve clinically important differences: a systematic review
    Lawrence, Kyle W.
    Rajahraman, Vinaya
    Meftah, Morteza
    Rozell, Joshua C.
    Schwarzkopf, Ran
    Arshi, Armin
    HIP INTERNATIONAL, 2024, 34 (05) : 578 - 587
  • [8] Robot-assisted surgery in total hip replacement
    Borner, M
    Bauer, A
    Lahmer, A
    UNFALLCHIRURG, 1997, 100 (08): : 640 - 645
  • [9] The use of Mako robot-assisted total hip arthroplasty in the treatment of Crowe IV developmental dysplasia of the hip
    Zhu, Yun-sen
    Mo, Ting-ting
    Zhang, Jiang-nan
    Jiang, Chang
    ASIAN JOURNAL OF SURGERY, 2022, 45 (06) : 1333 - 1335
  • [10] Total Hip Arthroplasty in Ankylosing Spondylitis With Extension Contracture of Hips
    Gautam, Deepak
    Malhotra, Rajesh
    JOURNAL OF ARTHROPLASTY, 2019, 34 (01) : 71 - 76