Simultaneous T-1-weighted and T-2-weighted 3D MRI using RF phase-modulated gradient echo imaging

被引:0
|
作者
Tamada, Daiki [1 ,2 ]
Field, Aaron S. [1 ,3 ]
Reeder, Scott B. [1 ,3 ,4 ,5 ,6 ]
机构
[1] Univ Wisconsin, Dept Radiol, Room 2480 Wisconsin Inst Med Res, Madison, WI 53705 USA
[2] Yamanashi Univ, Dept Radiol, Kofu, Yamanashi, Japan
[3] Univ Wisconsin, Dept Biomed Engn, Madison, WI 53705 USA
[4] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[5] Univ Wisconsin, Dept Med, Madison, WI 53705 USA
[6] Univ Wisconsin, Dept Emergency Med, Madison, WI 53705 USA
基金
美国国家卫生研究院;
关键词
gradient echo imaging; magnetic resonance imaging; RF phase modulation; T-1-weighted; T-2-weighted; STEADY-STATE; TRANSVERSE MAGNETIZATION; WATER; FAT; BRAIN;
D O I
10.1002/mrm.29077
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose T-1-weighted and T-2-weighted (T1w and T2w) imaging are essential sequences in routine clinical practice to detect and characterize a wide variety of pathologies. Many approaches have been proposed to obtain T1w and T2w contrast, although many challenges still remain, including long acquisition time and limitations that favor 2D imaging. In this study, we propose a novel method for simultaneous T1w and T2w imaging using RF phase-modulated 3D gradient-echo imaging. Theory Configuration theory is used to derive closed-form equations for the steady state of RF phase-modulated gradient-echo signal. These equations suggest the use of small RF phase increments to provide orthogonal signal contrast with T2w and T1w in the real and imaginary components, respectively. Background phase can be removed using a two-pass acquisition with opposite RF phase increments. Methods Simulation and phantom experiments were performed to validate our proposed method. Volunteer images of the brain and knee were acquired to demonstrate the clinical feasibility. The proposed method was compared with T1w and T2w fast spin-echo imaging. Results The relative signal intensity of images acquired using the proposed method agreed closely with simulations and fast spin-echo imaging in phantoms. Images from volunteer imaging showed very similar contrast compared to conventional fast spin-echo imaging. Conclusion Radiofrequency phase-modulated gradient-echo with small RF phase increments is an alternative method that provides simultaneous T1w and T2w contrast in short scan times with 3D volumetric coverage.
引用
收藏
页码:1758 / 1770
页数:13
相关论文
共 50 条
  • [1] Evaluation of Fetal Thyroid with 3D Gradient Echo T1-weighted MR Imaging
    Fujii, Shinya
    Nagaishi, Junichi
    Mukuda, Naoko
    Kaneda, Sachi
    Inoue, Chie
    Fukunaga, Takeru
    Ogawa, Toshihide
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2017, 16 (03) : 203 - 208
  • [2] Diagnostic value of 3D T1-weighted gradient-echo and 2D T1-weighted in-phase and out-of-phase gradient-echo sequences for appendicitis diagnosis in pregnant women
    Hung, Nguyen Duy
    Dung, Le Thanh
    Dung, Nguyen-Thi Kim
    Ha Khuong, Nguyen
    Anh, Nguyen Hai
    Duc, Nguyen Minh
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2023, 13 : 1 - 6
  • [3] Fat-suppressed 3D-T1-weighted-echo planar imaging: comparison with fat-suppressed 3D-T1-weighted-gradient echo in imaging the cartilage of the knee
    Karantanas, AH
    Zibis, AH
    Kitsoulis, P
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 159 - 165
  • [4] Clinical Value of 3D T2*-weighted Imaging with Multi-echo Acquisition: Comparison with Conventional 2D T2*-weighted Imaging and 3D Phase-sensitive MR Imaging
    Kunimatsu, Akira
    Suzuki, Yuichi
    Hagiwara, Kazuchika
    Sasaki, Hiroki
    Mori, Harushi
    Katsura, Masaki
    Ohtomo, Kuni
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (03) : 205 - 211
  • [5] VOLUME T1-WEIGHTED GRADIENT ECHO MRI IN MULTIPLE-SCLEROSIS PATIENTS
    SHAH, M
    ROSS, JS
    VANDYKE, C
    RUDICK, RA
    GOODKIN, DE
    OBUCHOWSKI, N
    MODIC, MT
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (05) : 731 - 736
  • [6] T1-weighted imaging of the brain at 3 tesla using a 2-dimensional spoiled gradient echo technique
    Runge, VM
    Patel, MC
    Baumann, SS
    Simonetta, AB
    Ponzo, JA
    Lesley, WS
    Calderwood, GW
    Naul, LG
    INVESTIGATIVE RADIOLOGY, 2006, 41 (02) : 68 - 75
  • [7] T1-Weighted 3D Dynamic Contrast-Enhanced MRI of the Breast Using a Dual-Echo Dixon Technique at 3 T
    Dogan, Basak E.
    Ma, Jingfei
    Hwang, Ken
    Liu, Ping
    Yang, Wei Tse
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) : 842 - 851
  • [8] An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping
    Keerthivasan, Mahesh Bharath
    Saranathan, Manojkumar
    Johnson, Kevin
    Fu, Zhiyang
    Weinkauf, Craig C.
    Martin, Diego R.
    Bilgin, Ali
    Altbach, Maria I.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 326 - 341
  • [9] Diagnosis of intracranial hemorrhagic lesions: comparison between 3D-SWAN (3D T2*-weighted imaging with multi-echo acquisition) and 2D-T2*-weighted imaging
    Hayashida, Yoshiko
    Kakeda, Shingo
    Hiai, Yasuhiro
    Ide, Satoshi
    Ogasawara, Atsushi
    Ooki, Hodaka
    Watanabe, Keita
    Nishimura, Joji
    Ohnari, Norihiro
    Korogi, Yukunori
    ACTA RADIOLOGICA, 2014, 55 (02) : 201 - 207
  • [10] Susceptibility-Weighted Imaging is More Reliable Than T2*-Weighted Gradient-Recalled Echo MRI for Detecting Microbleeds
    Cheng, Ah-Ling
    Batool, Saima
    McCreary, Cheryl R.
    Lauzon, M. L.
    Frayne, Richard
    Goyal, Mayank
    Smith, Eric E.
    STROKE, 2013, 44 (10) : 2782 - 2786