Effect of pulse sequence parameter selection on signal strength in positive-contrast MRI markers for MRI-based prostate postimplant assessment

被引:14
作者
Lim, Tze Yee [1 ,2 ]
Kudchadker, Rajat J. [1 ]
Wang, Jihong [1 ]
Stafford, R. Jason [3 ]
MacLellan, Christopher [2 ,3 ]
Rao, Arvind [4 ]
Ibbott, Geoffrey S. [1 ]
Frank, Steven J. [5 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[2] Univ Texas Houston, Grad Sch Biomed Sci, 6767 Bertner Ave, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Bioinformat & Computat Biol, 1515 Holcombe Blvd, Houston, TX 77030 USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, 1515 Holcombe Blvd, Houston, TX 77030 USA
关键词
MRI; marker; prostate; brachytherapy; N-ACETYL CYSTEINE; SEED; CT; LOCALIZATION; IMPLANT;
D O I
10.1118/1.4953635
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. Methods: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisition with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. Results: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. Conclusions: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:4312 / 4322
页数:11
相关论文
共 28 条
  • [1] Defining a magnetic resonance scan sequence for permanent seed prostate brachytherapy postimplant assessment
    Bowes, David
    Crook, Juanita M.
    Rajapakshe, Rasika
    Araujo, Cynthia
    Parker, Brent
    [J]. BRACHYTHERAPY, 2013, 12 (01) : 25 - 29
  • [2] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    [J]. RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [3] Center-out radial sampling with off-resonant reconstruction for efficient and accurate localization of punctate and elongated paramagnetic structures
    de Leeuw, H.
    Seevinck, P. R.
    Bakker, C. J. G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (06) : 1611 - 1622
  • [4] Dong Y., 2012, 34 ANN INT C IEEE EM
  • [5] Dong Y., 2013, 35 ANN INT C IEEE EM
  • [6] Susceptibility-based positive contrast MRI of brachytherapy seeds
    Dong, Ying
    Chang, Zheng
    Xie, Guoxi
    Whitehead, Gregory
    Ji, Jim X.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (03) : 716 - 726
  • [7] Source localization following permanent transperineal prostate interstitial brachytherapy using magnetic resonance imaging
    Dubois, DF
    Prestidge, BR
    Hotchkiss, LA
    Bice, WS
    Prete, JJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (05): : 1037 - 1041
  • [8] Towards MR-Only Image Guided Identification of Calcifications and Brachytherapy Seeds: Application to Prostate and Breast LDR Implant Dosimetry
    Elzibak, A.
    Fatemi-Ardekani, A.
    Soliman, A.
    Mashouf, S.
    Safigholi, H.
    Han, D.
    Ravi, A.
    Morton, G.
    Song, W. Y.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3315 - 3315
  • [9] Fatemi-Ardekani A., 2011, P INT SOC MAGNETIC R, V19, P3053
  • [10] A novel MRI marker for prostate brachytherapy
    Frank, Steven J.
    Stafford, R. Jason
    Bankson, James A.
    Li, Chun
    Swanson, David A.
    Kudchadker, Rajat J.
    Martirosyan, Karen S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : 5 - 8