Effect of Turning Vane Configurations on Heat Transfer and Pressure Drop in a Ribbed Internal Cooling System

被引:48
作者
Chen, Wei [1 ]
Ren, Jing [1 ]
Jiang, Hongde [1 ]
机构
[1] Tsinghua Univ, Dept Thermal Engn, Gas Turbine Res Ctr, Beijing 100084, Peoples R China
来源
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME | 2011年 / 133卷 / 04期
关键词
SMOOTH RECTANGULAR CHANNELS; 2-PASS SQUARE CHANNELS; FLOW; TURBULATORS; DUCT;
D O I
10.1115/1.4002989
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The ribbed serpentine blade cooling system is a typical configuration in the modern gas turbine airfoil. In this study, experimental and the numerical efforts were carried out to investigate the local heat transfer and pressure drop distribution of a ribbed blade cooling system with different configurations in the turn region. A test rig containing a ribbed rectangular U-duct with a 180 deg round turn was built in Tsinghua University for this study. The transient liquid crystal method was applied to get the heat transfer distribution. Nine test cases with three turn configurations under three Reynolds numbers were carried out in the experiment. Pressure was measured along the duct in order to determine the influence of turning vane configurations on pressure drop. The test cases were also analyzed numerically based on Reynolds-averaged Navier-Stokes (RANS) with three different turbulence models: the k-epsilon model, the SST reattachment model, and the Omega Reynolds stress (ORS) turbulence model. Both the experimental and numerical results showed a significant influence of the turning vane configuration on the heat transfer and pressure drop in the convective cooling channel. Among the three configurations, the loss coefficient of turn in configuration 2 was lowest due to the introduction of turning vane. Even the ribs were added in the turn region of configuration 3, the loss coefficient and friction factor are reduced by 23% and 17.5%, respectively. Meanwhile, the heat transfer in baseline configuration is still the highest. As the introduction of turning vane, the heat transfer in the region after turn was reduced by 35%. In configuration 3, the heat transfer in the turn region was enhanced by 15% as the ribs installed in the turn region. In the before turn region, the pressure drop and heat transfer was not influenced by the turn configuration. All the turbulence models captured the trend of heat transfer and pressure drop distribution of three test sections correctly, but all provide overpredicted heat transfer results. Among the models, the ORS turbulence model provided the best prediction. While aiming at high heat transfer level and low pressure drop, it is suggested that a suitable turn configuration, especially with the turning vane and/or the ribs, is a promising way to meet the conflicted requirements of the heat transfer and pressure drop in the convective cooling system. [DOI: 10.1115/1.4002989]
引用
收藏
页数:11
相关论文
共 26 条
[1]  
[Anonymous], GT200727830 ASME
[2]   Combined 3-D flow and heat transfer measurements in a 2-pass internal coolant passage of gas turbine airfoils [J].
Chanteloup, D ;
Juaneda, Y ;
Bölcs, A .
JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2002, 124 (04) :710-718
[3]  
Chen W., 2009, GT200959427 ASME
[4]   Detailed heat transfer measurements inside straight and tapered two-pass channels with rib turbulators [J].
Ekkad, SV ;
Pamula, G ;
Shantiniketanam, A .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2000, 22 (3-4) :155-163
[5]   Detailed heat transfer distributions in two-pass square channels with rib turbulators [J].
Ekkad, SV ;
Han, JC .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (11) :2525-2537
[6]  
Elfert M., 2004, ASME Paper GT2004-53566
[7]  
HAN JC, 1987, 179635 NASA
[8]  
HOCKER R, 1996, 96GT235 ASME
[9]   Computation of flow and heat transfer in two-pass channels with 60 deg ribs [J].
Jang, YJ ;
Chen, HC ;
Han, JC .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2001, 123 (03) :563-575
[10]  
Jenkins SC, 2008, PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 4, PTS A AND B, P1051