Static full-Stokes Fourier transform imaging spectropolarimeter capturing spectral, polarization, and spatial characteristics

被引:10
作者
Bai, Caixun [1 ,2 ]
Li, Jianxin [3 ]
Zhang, Wenfei [1 ]
Xu, Yixuan [3 ]
Feng, Yutao [2 ]
机构
[1] Shandong Univ Technol, Sch Phys & Optoelect Engn, Zibo 255000, Peoples R China
[2] Chinese Acad Sci, Key Lab Spectral Imaging Technol, Xian 710119, Peoples R China
[3] Nanjing Univ Sci & Technol, Sch Elect & Opt Engn, Nanjing 210094, Peoples R China
基金
中国国家自然科学基金;
关键词
POLARIMETER; MINIMIZATION; CALIBRATION; RESOLUTION; DESIGN; SYSTEM; SHOT;
D O I
10.1364/OE.443350
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A static full-Stokes Fourier transform imaging spectropolarimeter incorporating a liquid-crystal polarization modulator (LPM) and birefringent shearing interferometer (BSI) is reported. It can decode the polarization information at each wavelength along the spatial dimension of a two-dimensional data array. The LPM has a high-speed time-division architecture and employs two ferroelectric liquid crystals and two wave plates to produce four polarization states, providing full-Stokes polarimetric information with a high signal-to-noise ratio. The BSI comprises two birefringent crystal plates and generates an optical path difference with good linear distribution for broadband interference, allowing a fast and high-precision spectral recovery. The optimized design of LPM and BSI are introduced in detail. Subsequently, the signal reconstruction is verified through simulations and experiments. The proposed scheme is highly efficient, exhibits a higher spectral resolution, and constitutes a compact technical approach to realize high-dimensional optical measurement. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:38623 / 38645
页数:23
相关论文
共 39 条
[1]   Overdetermined broadband spectroscopic Mueller matrix polarimeter designed by genetic algorithms [J].
Aas, Lars Martin Sandvik ;
Ellingsen, Pal Gunnar ;
Fladmark, Bent Even ;
Letnes, Paul Anton ;
Kildemo, Morten .
OPTICS EXPRESS, 2013, 21 (07) :8753-8762
[2]   ACCURATE CALIBRATION OF THE 4-DETECTOR PHOTOPOLARIMETER WITH IMPERFECT POLARIZING OPTICAL-ELEMENTS [J].
AZZAM, RMA ;
LOPEZ, AG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1989, 6 (10) :1513-1521
[3]  
Bai C., 2017, INFRARED LASER ENG, V46
[4]   Compact birefringent interferometer for Fourier transform hyperspectral imaging [J].
Bai, Caixun ;
Li, Jianxin ;
Xu, Yixuan ;
Yuan, Heng ;
Liu, Jie .
OPTICS EXPRESS, 2018, 26 (02) :1703-1725
[5]   Infrared hyperspectral imaging polarimeter using birefringent prisms [J].
Craven-Jones, Julia ;
Kudenov, Michael W. ;
Stapelbroek, Maryn G. ;
Dereniak, Eustace L. .
APPLIED OPTICS, 2011, 50 (08) :1170-1185
[6]   Spectro-polarimetric imaging for object recognition [J].
Denes, LJ ;
Gottlieb, M ;
Kaminsky, B ;
Huber, DF .
EXPLOITING NEW IMAGE SOURCES AND SENSORS, 26TH AIPR WORKSHOP, 1998, 3240 :8-18
[7]   On the equivalence of optimization metrics in Stokes polarimetry [J].
Foreman, Matthew R. ;
Goudail, Francois .
OPTICAL ENGINEERING, 2019, 58 (08)
[8]  
Francon M., 1971, Polarization Interferometers
[9]   Noise minimization and equalization for Stokes polarimeters in the presence of signal-dependent Poisson shot noise [J].
Goudail, Francois .
OPTICS LETTERS, 2009, 34 (05) :647-649
[10]   Efficient subpixel image registration algorithms [J].
Guizar-Sicairos, Manuel ;
Thurman, Samuel T. ;
Fienup, James R. .
OPTICS LETTERS, 2008, 33 (02) :156-158