Impact on the thrombogenicity of surface oxide properties of 316l stainless steel for biomedical applications

被引:16
|
作者
Shih, CC
Shih, CM
Su, YY
Lin, SJ [1 ]
机构
[1] Natl Yang Ming Univ, Sch Med, Inst Clin Med, Div Cardiol, Taipei 112, Taiwan
[2] Vet Gen Hosp, Div Cardiovasc Surg, Taipei, Taiwan
[3] Natl Yang Ming Univ, Cardiovasc Res Ctr, Taipei 112, Taiwan
[4] Taipei Med Univ, Sch Med, Grad Inst Med Sci, Taipei, Taiwan
[5] Amorphous Oxide Technol Inc, Marietta, GA USA
[6] Vet Gen Hosp, Div Cardiol, Taipei 112, Taiwan
关键词
amorphous oxide; open-circuit potential; surface oxide; thrombosis; time constant;
D O I
10.1002/jbm.a.20013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Surface oxide film on cardiovascular devices could be one of the most critical factors that determine the degree of thrombosis. Previous studies have shown that metallic wire passivated with amorphous oxide film provides excellent corrosion and scratch resistance. Investigation was undertaken to see whether this oxide film, with its unique electrochemical properties, could reduce the development of thrombosis. Results show that amorphous oxide has higher value of time constant, lower open-circuit poten-tial, and lower degree of thrombosis. These distinguished characteristics prove amorphous oxide to be the best candidate for the cardiovascular devices. Amorphous oxide film could be a potential solution to the thrombogenic problem of cardiovascular devices. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:1320 / 1328
页数:9
相关论文
共 50 条
  • [1] Effect of surface oxide properties on corrosion resistance of 316L stainless steel for biomedical applications
    Shih, CC
    Shih, CM
    Su, YY
    Su, LHJ
    Chang, MS
    Lin, SJ
    CORROSION SCIENCE, 2004, 46 (02) : 427 - 441
  • [2] Processing and mechanical properties of porous 316L stainless steel for biomedical applications
    Dewidar, Montasser M.
    Khalil, Khalil A.
    Lim, J. K.
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2007, 17 (03) : 468 - 473
  • [3] Processing and mechanical properties of porous 316L stainless steel for biomedical applications
    Montasser M. DEWIDAR
    Khalil A. KHALIL
    J. K. LIM
    Transactions of Nonferrous Metals Society of China, 2007, (03) : 468 - 473
  • [4] Fabrication of Porous Stainless Steel 316L for Biomedical Applications
    Noor, F. Mat
    Jamaludin, K. R.
    Ahmad, S.
    8TH INTERNATIONAL CONFERENCE ON MECHANICAL AND MANUFACTURING ENGINEERING 2017 (ICME'17), 2017, 135
  • [5] Tribological behaviour of AISI 316L stainless steel for biomedical applications
    Fellah, M.
    Labaiz, M.
    Assala, O.
    Iost, A.
    Dekhil, Leila
    TRIBOLOGY-MATERIALS SURFACES & INTERFACES, 2013, 7 (03) : 135 - 149
  • [6] Process mapping of laser surface modification of AISI 316L stainless steel for biomedical applications
    Evans Chikarakara
    Sumsun Naher
    Dermot Brabazon
    Applied Physics A, 2010, 101 : 367 - 371
  • [7] Electrochemical and chemical methods for improving surface characteristics of 316L stainless steel for biomedical applications
    Latifi, Afrooz
    Imani, Mohammad
    Khorasani, Mohammad Taghi
    Joupari, Morteza Daliri
    SURFACE & COATINGS TECHNOLOGY, 2013, 221 : 1 - 12
  • [8] Process mapping of laser surface modification of AISI 316L stainless steel for biomedical applications
    Chikarakara, Evans
    Naher, Sumsun
    Brabazon, Dermot
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2010, 101 (02): : 367 - 371
  • [9] Production of 316L Stainless Steel Used In Biomedical Applications By Powder Metallurgy
    Muratal, Onur
    Yamanoglu, Ridvan
    2019 SCIENTIFIC MEETING ON ELECTRICAL-ELECTRONICS & BIOMEDICAL ENGINEERING AND COMPUTER SCIENCE (EBBT), 2019,
  • [10] The Effect of Nitrided Layer on Antibacterial Properties of Biomedical 316L Stainless Steel
    Benegra, M.
    Couto, G. H.
    Bernardelli, E. A.
    XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 127 - 131