Comparison of the Carbon Nanofiber-/Fiber- and Silicone-Based Electrodes for Bioimpedance Measurements

被引:5
作者
Koiv, Hip [1 ]
Pesti, Ksenija [1 ]
Min, Mart [1 ]
Land, Raul [1 ]
Must, Indrek [2 ]
机构
[1] Tallinn Univ Technol, Thomas Johann Seebeck Dept Elect, EE-19086 Tallinn, Estonia
[2] Univ Tartu, Intelligent Mat & Syst Lab, EE-50090 Tartu, Estonia
基金
欧盟地平线“2020”;
关键词
Bioimpedance; carbon nanofiber; carbon fiber; electrodes; electrode-skin interface impedance; SKIN IMPEDANCE; FREQUENCY; INTERFACE;
D O I
10.1109/TIM.2019.2962297
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrodes for bioimpedance measurements remain a challenge. In practice, commercially available nonpolarizable silver/silver chloride (Ag/AgCl) gel electrodes prove to be the best option for bioimpedance-based testing. The hydrogel layer reduces the problematic electrode-skin interface impedance, which results in a highly reliable signal. Our workgroup is developing a wearable device that estimates aortic blood pressure from the bioimpedance taken from the wrist area. Understandably, wet electrodes do not suit for a wearable, and there is a need for dry, soft, reusable, and stable electrodes. This study proposes stretchable carbon nanofiber/carbon fiber silicone electrodes as an alternative for cardiac signal measurements with bioimpedance. Five different electrode materials are tested and analyzed: Ag/AgCl gel, Ag/AgCl dry, two carbon and silicone composite materials, and carbon textile. To compare the electrodes' characteristics, the current through the tissue under the changing pressure, frequency, contact duration, and skin preparation is registered, and the electrode-skin impedance is calculated. The soft and stretchable carbon fiber silicone electrodes proved to have similar response as rigid nonpolarizable Ag/AgCl dry electrodes. Selected methods and proposed instrumentation ensure acceptable reproducibility of the base value and the modulation depth of the measured impedance despite the different electrode materials, large variation of the electrode-skin impedance, and the actual measurement current.
引用
收藏
页码:1455 / 1463
页数:9
相关论文
共 26 条
  • [1] Miniature ambulatory skin conductance monitor and algorithm for investigating hot flash events
    Bahr, Dennis E.
    Webster, John G.
    Grady, Deborah
    Kronenberg, Fredi
    Creasman, Jennifer
    Macer, Judy
    Shults, Mark
    Tyler, Mitchell
    Zhou, Xin
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (02) : 95 - 110
  • [2] Bosnjak A, 2017, IEEE ENG MED BIO, P1861, DOI 10.1109/EMBC.2017.8037209
  • [3] Caytak H, 2019, ENCYCLOPEDIA OF BIOMEDICAL ENGINEERING, VOL 3, P265, DOI 10.1016/B978-0-12-801238-3.10884-0
  • [4] Development of printed and flexible dry ECG electrodes
    Chlaihawi, Amer Abdulmahdi
    Narakathu, Binu Baby
    Emamian, Sepehr
    Bazuin, Bradley J.
    Atashbar, Massood Z.
    [J]. SENSING AND BIO-SENSING RESEARCH, 2018, 20 : 9 - 15
  • [5] The origin of skin-stretch-caused motion artifacts under electrodes
    deTalhouet, H
    Webster, JG
    [J]. PHYSIOLOGICAL MEASUREMENT, 1996, 17 (02) : 81 - 93
  • [6] Fish Raymond M, 2009, Eplasty, V9, pe44
  • [7] CNT/PDMS Composite Flexible Dry Electrodes for Long-Term ECG Monitoring
    Jung, Ha-Chul
    Moon, Jin-Hee
    Baek, Dong-Hyun
    Lee, Jae-Hee
    Choi, Yoon-Young
    Hong, Joung-Sook
    Lee, Sang-Hoon
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (05) : 1472 - 1479
  • [8] Homogeneous transport in a heterogeneous membrane: Water diffusion across human stratum corneum in vivo
    Kalia, YN
    Pirot, F
    Guy, RH
    [J]. BIOPHYSICAL JOURNAL, 1996, 71 (05) : 2692 - 2700
  • [9] Measurements of Electrode Skin Impedances using Carbon Rubber Electrodes - First Results
    Kaufmann, Steffen
    Ardelt, Gunther
    Ryschka, Martin
    [J]. XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [10] Bioinspired, Highly Stretchable, and Conductive Dry Adhesives Based on 1D-2D Hybrid Carbon Nanocomposites for All-in-One ECG Electrodes
    Kim, Taehoon
    Park, Junyong
    Sohn, Jongmoo
    Cho, Donghwi
    Jeon, Seokwoo
    [J]. ACS NANO, 2016, 10 (04) : 4770 - 4778