Relationship Between Simulated Gadolinium-Based Contrast Agent Injection Profile and Achievable Resolution Metrics in Contrast-Enhanced Magnetic Resonance Angiography

被引:2
作者
Clark, Toshimasa J. [1 ]
Wilson, Gregory J. [2 ]
Maki, Jeffrey H. [1 ]
机构
[1] Univ Colorado, Dept Radiol, Abdominal Imaging Sect, Aurora, CO USA
[2] Bayer Healthcare, Bayer Radiol, Whippany, NJ USA
关键词
magnetic resonance angiography; contrast-enhanced magnetic resonance angiography; simulation; GADOBENATE DIMEGLUMINE; LIMITS;
D O I
10.1002/jmri.27966
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Contrast bolus variation during contrast-enhanced magnetic resonance angiography (CE-MRA) acquisition may lead to vessel blurring. Purpose To combine knowledge of how contrast signal intensity (SI) evolves for different injection strategies with anatomically familiar parametric computer models to measure and visually assess the effects of a wide range of variables on modeled CE-MRA, and in doing so develop contrast rate injection guidelines. Study Type Computer modeling. Phantom Digital three-dimensional phantom consisting of orthogonal "aorta," 7 mm diameter "renal arteries" (with 57% and 86% diameter stenoses), and 7 mm diameter "superior mesenteric artery" (with 57% diameter stenosis). Field Strength/Sequence One millimeter in-plane resolution arterial CE-MRA imaging at 3 T. Assessment "Background" (time invariant) and "vascular" (time varying) components of the phantom were each Fourier transformed into the spatial frequency domain, the latter modulated by the SI evolution of a contrast bolus of varying "plateau" lengths and "tail" heights. Data are presented as surface plots of stenosis measurement error and blurring vs. a reference-standard injection. Statistical Tests Descriptive. Results Shorter plateau lengths and lower tail heights resulted in increased measured stenosis error and blurring vs. the reference standard. Under a 44-second acquisition, full width half maximum stenosis error of the 86% stenosis with 25% plateau length and 25% tail height is 24% as compared to that from the reference standard. As plateau length and tail height approach 100%, stenosis error and blurring approach a floor defined by the MR acquisition's limitations. Data Conclusion We propose that to achieve minimal degradation with CE-MRA, one can create a contrast bolus with either 60% plateau and 50% tail height or 80% plateau with any tail. These considerations may well prove to be of practical importance, possibly via manipulating the tail by means of multiphasic contrast injections. Level of Evidence 3 Technical Efficacy Stage 1
引用
收藏
页码:1797 / 1807
页数:11
相关论文
共 50 条
  • [21] Intravenous gadolinium-based hepatocyte-specific contrast agents (HSCAs) for contrast-enhanced liver magnetic resonance imaging in pediatric patients: what the radiologist should know
    Ayyala, Rama S.
    Anupindi, Sudha A.
    Gee, Michael S.
    Trout, Andrew T.
    Callahan, Michael J.
    [J]. PEDIATRIC RADIOLOGY, 2019, 49 (10) : 1256 - 1268
  • [22] Gadolinium(III) Complex-Backboned Branched Polymers as Imaging Probes for Contrast-Enhanced Magnetic Resonance Angiography
    Fu, Shengxiang
    Cai, Zhongyuan
    Liu, Li
    Fu, Xiaomin
    Wu, Changqiang
    Du, Liang
    Xia, Chunchao
    Lui, Su
    Gong, Qiyong
    Song, Bin
    Ai, Hua
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (14) : 18311 - 18322
  • [23] Amorphous Albumin Gadolinium-Based Nanoparticles for Ultrahigh-Resolution Magnetic Resonance Angiography
    Liu, Chenchen
    Liu, Xiaoming
    Wei, Zhihao
    Chang, Zong
    Bai, Yaowei
    Zeng, Pei
    Cao, Qi
    Tie, Changjun
    Lei, Ziqiao
    Sun, Peng
    Liang, Huageng
    Sun, Qinchao
    Zhang, Xiaoping
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (08) : 9702 - 9712
  • [24] Dynamic contrast-enhanced magnetic resonance angiography of vascular malformations in pediatric patients
    Mukundan, Srinivasan
    Fuchs, Herbert
    Alexander, Michael J.
    Grant, Gerald A.
    [J]. JOURNAL OF NEUROSURGERY, 2007, 107 (03) : 228 - 231
  • [25] Standardized volume-rendering of contrast-enhanced renal magnetic resonance angiography
    Smedby, Ö
    Öberg, R
    Åsberg, B
    Stenström, H
    Eriksson, P
    [J]. ACTA RADIOLOGICA, 2005, 46 (05) : 497 - 504
  • [26] Contrast-enhanced magnetic resonance angiography of the cervical vessels - Experience with 422 patients
    Phan, T
    Huston, J
    Bernstein, MA
    Riederer, SJ
    Brown, RD
    [J]. STROKE, 2001, 32 (10) : 2282 - 2286
  • [27] Contrast-enhanced three-dimensional magnetic resonance angiography of the mesenteric vasculature
    Baden, JG
    Racy, DJ
    Grist, TM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (03): : 369 - 375
  • [28] Role of Contrast-Enhanced Magnetic Resonance Angiography in Spinal Dural Arteriovenous Fistula
    Toni, F.
    Cirillo, L.
    Marliani, A. F.
    Riccioli, L. Albini
    Leonardi, M.
    [J]. NEURORADIOLOGY JOURNAL, 2010, 23 (02) : 234 - 243
  • [29] Contrast-enhanced magnetic resonance angiography. Theory, technique and practical application
    Stehling, MK
    Niedermeyer, M
    Laub, G
    [J]. RADIOLOGE, 1997, 37 (07): : 501 - 507
  • [30] CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY FOR DIAGNOSIS OF PORTOSYSTEMIC SHUNTS IN 10 DOGS
    Bruehschwein, Andreas
    Foltin, Isa
    Flatz, Katharina
    Zoellner, Martin
    Matis, Ulrike
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (02) : 116 - 121