Relationship Between Simulated Gadolinium-Based Contrast Agent Injection Profile and Achievable Resolution Metrics in Contrast-Enhanced Magnetic Resonance Angiography

被引:2
作者
Clark, Toshimasa J. [1 ]
Wilson, Gregory J. [2 ]
Maki, Jeffrey H. [1 ]
机构
[1] Univ Colorado, Dept Radiol, Abdominal Imaging Sect, Aurora, CO USA
[2] Bayer Healthcare, Bayer Radiol, Whippany, NJ USA
关键词
magnetic resonance angiography; contrast-enhanced magnetic resonance angiography; simulation; GADOBENATE DIMEGLUMINE; LIMITS;
D O I
10.1002/jmri.27966
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Contrast bolus variation during contrast-enhanced magnetic resonance angiography (CE-MRA) acquisition may lead to vessel blurring. Purpose To combine knowledge of how contrast signal intensity (SI) evolves for different injection strategies with anatomically familiar parametric computer models to measure and visually assess the effects of a wide range of variables on modeled CE-MRA, and in doing so develop contrast rate injection guidelines. Study Type Computer modeling. Phantom Digital three-dimensional phantom consisting of orthogonal "aorta," 7 mm diameter "renal arteries" (with 57% and 86% diameter stenoses), and 7 mm diameter "superior mesenteric artery" (with 57% diameter stenosis). Field Strength/Sequence One millimeter in-plane resolution arterial CE-MRA imaging at 3 T. Assessment "Background" (time invariant) and "vascular" (time varying) components of the phantom were each Fourier transformed into the spatial frequency domain, the latter modulated by the SI evolution of a contrast bolus of varying "plateau" lengths and "tail" heights. Data are presented as surface plots of stenosis measurement error and blurring vs. a reference-standard injection. Statistical Tests Descriptive. Results Shorter plateau lengths and lower tail heights resulted in increased measured stenosis error and blurring vs. the reference standard. Under a 44-second acquisition, full width half maximum stenosis error of the 86% stenosis with 25% plateau length and 25% tail height is 24% as compared to that from the reference standard. As plateau length and tail height approach 100%, stenosis error and blurring approach a floor defined by the MR acquisition's limitations. Data Conclusion We propose that to achieve minimal degradation with CE-MRA, one can create a contrast bolus with either 60% plateau and 50% tail height or 80% plateau with any tail. These considerations may well prove to be of practical importance, possibly via manipulating the tail by means of multiphasic contrast injections. Level of Evidence 3 Technical Efficacy Stage 1
引用
收藏
页码:1797 / 1807
页数:11
相关论文
共 50 条
  • [1] Contrast-Enhanced Magnetic Resonance Angiography
    Vasile, Julie V.
    Newman, Tiffany M.
    Prince, Martin R.
    Rusch, David G.
    Greenspun, David T.
    Allen, Robert J.
    Levine, Joshua L.
    CLINICS IN PLASTIC SURGERY, 2011, 38 (02) : 263 - +
  • [2] Contrast-Enhanced Magnetic Resonance Angiography
    Chandra, Tushar
    Pukenas, Bryan
    Mohan, Suyash
    Melhem, Elias
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 687 - +
  • [3] Contrast-enhanced MR Angiography without Gadolinium-based Contrast Material: Clinical Applications Using Ferumoxytol
    Jalili, Mohammad H.
    Yu, Tiffany
    Hassani, Cameron
    Prosper, Ashley E.
    Finn, J. Paul
    Bedayat, Arash
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2022, 4 (04):
  • [4] Toxicity associated with gadolinium-based contrast-enhanced examinations
    Lattanzio, Silvia Maria
    AIMS BIOPHYSICS, 2021, 8 (02): : 198 - 220
  • [5] Contrast-enhanced magnetic resonance angiography of the iliac arteries: Optimization by injection simulation
    Schmidt, MA
    Britten, AJ
    Tomlinson, MA
    Vig, S
    Powell, S
    Cleminson, S
    Kerr, E
    Blundell, J
    Heron, CW
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 365 - 373
  • [6] Contrast-Enhanced Magnetic Resonance Angiography Evaluation of the High Relaxivity Low Diffusible Gadolinium-Based Contrast Agent P846 in Comparison With Gadoterate Meglumine in Rabbits at 1.5 Tesla and 3.0 Tesla
    Peldschus, Kersten
    Hamdorf, Mereike
    Robert, Philippe
    Port, Marc
    Graessner, Joachim
    Adam, Gerhard
    Herborn, Christoph U.
    INVESTIGATIVE RADIOLOGY, 2008, 43 (12) : 837 - 842
  • [7] Recent advances in contrast-enhanced magnetic resonance angiography
    Meaney, James F. M.
    Goyen, Mathias
    EUROPEAN RADIOLOGY, 2007, 17 : B2 - B6
  • [8] Gadolinium-Based Magnetic Resonance Contrast Agents for Neuroradiology: An Overview
    Kanal, Emanuel
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 625 - +
  • [9] Gadolinium-based contrast agents in pediatric magnetic resonance imaging
    Gale, Eric M.
    Caravan, Peter
    Rao, Anil G.
    McDonald, Robert J.
    Winfeld, Matthew
    Fleck, Robert J.
    Gee, Michael S.
    PEDIATRIC RADIOLOGY, 2017, 47 (05) : 507 - 521
  • [10] Contrast-enhanced magnetic resonance angiography of peripheral vessels - Different contrast agent applications and sequence strategies: A review
    Boos, M
    Lentschig, M
    Scheffler, K
    Bongartz, GM
    Steinbrich, W