The performance of SBR, SCR, and MSCR for simultaneous biodegradation of high concentrations of formaldehyde and ammonia

被引:31
作者
Moussavi, Gholamreza [1 ]
Heidarizad, Mandi [1 ]
机构
[1] Tarbiat Modares Univ, Fac Med Sci, Dept Environm Hlth, Tehran, Iran
关键词
Formaldehyde; Ammonia; SBR; Continuous flow; Moving bed; WASTE-WATER; NITROGEN REMOVAL; BIOFILM-REACTOR; SIMULTANEOUS NITRIFICATION; DISSOLVED-OXYGEN; DEGRADATION; DENITRIFICATION; UREA; WASTEWATERS; NITRITE;
D O I
10.1016/j.seppur.2010.11.028
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents experimental results for the simultaneous removal of formaldehyde (CH2O) and ammonia nitrogen using three bioreactors: a sequencing batch reactor (SBR), a sequencing continuous-inflow reactor (SCR), and a novel modified moving-bed SCR (MSCR). The performance of these bioreactors was first investigated in terms of removal of CH2O and COD. The MSCR achieved the highest removal capacity: 100% of the CH2O and 97% of the COD at an inlet loading rate of 1.25 kg CH2O/m(3) d (1.8 kg COD/m(3) d) over a 24-h cycle time. The SCR was the next most efficient bioreactor. The nitrogen removal performance of the SCR and the MSCR was also studied. Results indicated that the MSCR removed approximately 99.9% of the nitrogen at a loading rate of 1.25 kg N/m(3) d in the presence of 1.25 kg CH2O/m(3) d. This work showed the MSCR to be an efficient modification of the activated sludge process for concurrently obtaining CH2O and nitrogen removal. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 35 条
[1]   MECHANISM OF FORMALDEHYDE BIODEGRADATION BY PSEUDOMONAS-PUTIDA [J].
ADROER, N ;
CASAS, C ;
DEMAS, C ;
SOLA, C .
APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1990, 33 (02) :217-220
[2]  
[Anonymous], 1998, STAND METH EXAM WAT
[3]   Coupled BAS and anoxic USB system to remove urea and formaldehyde from wastewater [J].
Campos, JL ;
Sánchez, M ;
Mosquera-Corral, A ;
Méndez, R ;
Lema, JM .
WATER RESEARCH, 2003, 37 (14) :3445-3451
[4]   ORGANIC-CARBON SUPPLEMENT INFLUENCING PERFORMANCE OF BIOLOGICAL NITRITIFICATION IN A FLUIDIZED-BED REACTOR [J].
CHENG, SS ;
CHEN, WC .
WATER SCIENCE AND TECHNOLOGY, 1994, 30 (11) :131-142
[5]   Simultaneous nitrification and formaldehyde biodegradation in an activated sludge unit [J].
Eiroa, M ;
Kennes, C ;
Veiga, MC .
BIORESOURCE TECHNOLOGY, 2005, 96 (17) :1914-1918
[6]   Treatment of wastewaters from a formaldehyde-urea adhesives factory [J].
Garrido, JM ;
Méndez, R ;
Lema, JM .
WATER SCIENCE AND TECHNOLOGY, 2000, 42 (5-6) :293-300
[7]   Simultaneous urea hydrolysis, formaldehyde removal and denitrification in a multifed upflow filter under anoxic and anaerobic conditions [J].
Garrido, JM ;
Méndez, R ;
Lema, JM .
WATER RESEARCH, 2001, 35 (03) :691-698
[8]  
Gerardi MH., 2002, NITRIFICATION DENITR
[9]  
Glancer-Soljan M, 2001, FOOD TECHNOL BIOTECH, V39, P197
[10]   Simultaneous removal of organic matter and nitrogen compounds by combining a membrane bioreactor and a membrane biofilm reactor [J].
Hasar, Halil .
BIORESOURCE TECHNOLOGY, 2009, 100 (10) :2699-2705