High-performance liquid chromatographic method with diode array detection for identification and quantification of the eight new antidepressants and five of their active metabolites in plasma after overdose

被引:103
作者
Titier, K
Castaing, N
Scotto-Gomez, E
Pehourcq, F
Moore, N
Molimard, M
机构
[1] Hop Pellegrin, Lab Pharmacol Clin & Toxicol, Dept Clin Pharmacol & Toxicol, F-33076 Bordeaux, France
[2] Univ Victor Segalen, F-33076 Bordeaux, France
关键词
liquid chromatography; antidepressants; toxicology;
D O I
10.1097/00007691-200310000-00007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
A high-performance liquid chromatographic method is described for the determination of selective serotonin reuptake inhibitors (fluvoxamine, paroxetine, sertraline, fluoxetine, citalopram, mirtazapine), serotonin norepinephrine reuptake inhibitors (milnacipram, venlafaxine), a noradrenergic and specific serotoninergic antidepressant (mirtazapine), and five pharmacologically active metabolites (desmethylcitalopram, didesmethylcitalopram, norfluoxetine, O-desmethylvenlafaxine, desmethylmirtazapine). After a double-step liquid-liquid extraction, compounds are separated on a Symmetry((R)) C-8 column eluted with a gradient of acetonitrile-phosphate buffer 10 mM pH 3.8 and detected at 230 nm and 290 nm. Calibration curves were linear in the range 25 to 500 ng/mL (100-2000 ng/mL for venlafaxine and its metabolite). The limit of quantification was 25 ng/mL (100 ng/mL for venlafaxine and its metabolite). For all quality controls good accuracy was achieved (93% to 99.5%) with intraday and interday variation coefficients less than 12%. This method allows simple and rapid (run time 18 min) identification and quantification of the eight new antidepressants and five of their active metabolites. This method can be used for toxicologic purpose.
引用
收藏
页码:581 / 587
页数:7
相关论文
共 15 条
[1]   Massive sertraline overdose [J].
Brendel, DH ;
Bodkin, JA ;
Yang, JM .
ANNALS OF EMERGENCY MEDICINE, 2000, 36 (05) :524-526
[2]   Simultaneous determination of human plasma levels of citalopram, paroxetine, sertraline, and their metabolites by gas chromatography mass spectrometry [J].
Eap, CB ;
Bouchoux, G ;
Amey, M ;
Cochard, N ;
Savary, L ;
Baumann, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1998, 36 (07) :365-371
[3]  
Goeringer KE, 2000, J FORENSIC SCI, V45, P633
[4]   Citalopram in fatal poisoning cases [J].
Jonasson, B ;
Saldeen, T .
FORENSIC SCIENCE INTERNATIONAL, 2002, 126 (01) :1-6
[5]   SNaRIs, NaSSAs, and NaRIs: new agents for the treatment of depression [J].
Kent, JM .
LANCET, 2000, 355 (9207) :911-918
[6]   Simultaneous determination of citalopram, fluoxetine, paroxetine and their metabolites in plasma and whole blood by high-performance liquid chromatography with ultraviolet and fluorescence detection [J].
Kristoffersen, L ;
Bugge, A ;
Lundanes, E ;
Slordal, L .
JOURNAL OF CHROMATOGRAPHY B, 1999, 734 (02) :229-246
[7]   Separation of new antidepressants and their metabolites by micellar electrokinetic capillary chromatography [J].
Labat, L ;
Deveaux, M ;
Dallet, P ;
Dubost, JP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :17-23
[8]  
Lacassie E, 1999, ACTA CLIN BELG, P20
[9]   Methods for the determination of seven selective serotonin reuptake inhibitors and three active metabolites in human serum using high-performance liquid chromatography and gas chromatography [J].
Lacassie, E ;
Gaulier, JM ;
Marquet, P ;
Rabatel, JF ;
Lachâtre, G .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02) :229-238
[10]   Simultaneous determination of human plasma levels of four selective serotonin reuptake inhibitors by high-performance liquid chromatography [J].
Lucca, A ;
Gentilini, G ;
Lopez-Silva, S ;
Soldarini, A .
THERAPEUTIC DRUG MONITORING, 2000, 22 (03) :271-276