Estimating Correlation between Arterial Blood Pressure and Photoplethysmograph

被引:5
作者
Abhay, Theertha [1 ]
Kayalvizhi, N. [1 ]
Gini, Rolant J. [1 ]
机构
[1] Amrita Univ, Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Dept Elect & Commun Engn, Coimbatore, Tamil Nadu, India
来源
16TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING | 2017年 / 61卷
关键词
Arterial Blood Pressure (ABP); PPG; Elasticity of artery; Segmentation;
D O I
10.1007/978-981-10-4220-1_10
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photoplethysmograph (PPG) and Arterial Blood Pressure (ABP) are good indicators of cardiovascular performance. Although ABP is more widely employed, the invasive procedure of signal acquisition may cause skin rashes and inconvenience to the patients. Also, it does not allow continuous monitoring of cardiac activity. PPG, on the other hand, uses infrared light to measure the blood volume changes, which is a simple, non-invasive and can be used for continuous measurement. This paper focuses on analyzing the similarity between ABP and PPG using various features like average slope, peak position, time period, elasticity, amplitude of the signal. A segmentation algorithm was used to segment out cycles of ABP and PPG from physionet database taken from 19 patients with respiratory failure and the values of each feature were extracted for each person. Considering the population, using Pearson's correlation coefficient, the coefficient for the average slope of the PPG and peak to peak amplitude of ABP was found to be 0.55 indicating that other factors such as vessel diameter, thickness must be considered. The upstroke time period of both ABP and PPG was found to have a small difference in the range of 0.02s to 0.1s, whereas the time period of the heart cycles remained the same irrespective of the disease or healthy condition. The peak value of both ABP and PPG was found to occur with constant time difference. The elasticity with peak to peak amplitude of ABP was found to have a correlation of 0.822, and with systolic blood pressure, a correlation of 0.7622. When considered for individuals, parameters like the diastolic average slope of PPG and systolic blood pressure were found to have a good correlation coefficient ranging from 0.6 to 0.96 among other parameters which include systolic average slope, maximum and minimum slope of PPG, and the diastolic blood pressure.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 9 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]  
[Anonymous], 2009, P INT C BIOM PHARM E
[3]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[4]  
He X, 2013, ENCY MEMBRANE SCI TE, P1, DOI [10.1002/9781118522318.emst094, DOI 10.1002/9781118522318.EMST094]
[5]  
Hsiu H., 2012, INT J BIOSCI BIOCH B, V2
[6]   A Biomedical Signal Segmentation Algorithm for Event Detection Based on Slope Tracing [J].
Kim, Jungkuk ;
Kim, Minkyu ;
Won, Injae ;
Yang, Seungyhul ;
Lee, Kiyoung ;
Huh, Woong .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :1889-+
[7]  
Samria R, 2014, IEEE REGION 10 SYMP, P254, DOI 10.1109/TENCONSpring.2014.6863037
[8]  
SHALTIS P, 2005, C P IEEE ENG MED BIO, P3970
[9]   Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach [J].
Teng, XF ;
Zhang, YT .
PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 :3153-3156