United Iterative Reconstruction for Spectral Computed Tomography

被引:32
作者
Xi, Yan [1 ]
Chen, Yi [1 ]
Tang, Rongbiao [2 ]
Sun, Jianqi [1 ]
Zhao, Jun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 200030, Peoples R China
[2] Shanghai Jiao Tong Univ, Ruijin Hosp, Sch Med, Dept Radiol, Shanghai 200025, Peoples R China
基金
中国国家自然科学基金;
关键词
Computed tomography; image reconstruction; iterative methods; photon counting; DUAL-ENERGY CT; CLINICAL-APPLICATIONS; REDUCTION; SYSTEM; NOISE;
D O I
10.1109/TMI.2014.2339497
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Spectral computed tomography (CT) has attracted considerable attention because of its energy-resolving capability in identifying and discriminating materials. The use of a narrow energy bin can improve energy resolution. However, a narrow energy bin has high noise ratio, which degrades the imaging quality of spectral CT. To address this problem, this study exploits the structure correlations of images in the energy domain and proposed two types of united iterative reconstruction (UIR) algorithms. One type uses the well-reconstructed broad-spectrum image, with all available photons, as a constraint, whereas the other type uses a pseudo narrow-energy image, which is estimated with the use of our proposed structure-coupling (SC) method, as a constraint. The SC method utilizes local structures to connect images that are reconstructed with broad-spectrum and narrow-energy CT datasets. Given a broad-spectrum image, the SC method can accurately estimate its corresponding narrow-energy image. Results show that UIR algorithms significantly outperform conventional iterative reconstruction algorithms for narrow-energy image reconstruction in spectral CT. Among the UIR algorithms, SC-UIR yields the best results.
引用
收藏
页码:769 / 778
页数:10
相关论文
共 42 条
[1]   Comparison of dual energy detector system performance [J].
Alvarez, RE ;
Seibert, JA ;
Thompson, SK .
MEDICAL PHYSICS, 2004, 31 (03) :556-565
[2]  
Barber WC, 2009, SPIE MED IMAGING
[3]   Hybrid Spectral Micro-CT: System Design, Implementation, and Preliminary Results [J].
Bennett, James R. ;
Opie, Alex M. T. ;
Xu, Qiong ;
Yu, Hengyong ;
Walsh, Michael ;
Butler, Anthony ;
Butler, Phillip ;
Cao, Guohua ;
Mohs, Aaron ;
Wang, Ge .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) :246-253
[4]  
Bones P. J., 2010, SPIE OPT ENG APPL
[5]   Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study [J].
Bornefalk, Hans ;
Danielsson, Mats .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07) :1999-2022
[6]   Bio-medical X-ray imaging with spectroscopic pixel detectors [J].
Butler, A. P. H. ;
Anderson, N. G. ;
Tipples, R. ;
Cook, N. ;
Watts, R. ;
Meyer, J. ;
Bell, A. J. ;
Melzer, T. R. ;
Butler, P. H. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 591 (01) :141-146
[7]   SPLIT BREGMAN METHODS AND FRAME BASED IMAGE RESTORATION [J].
Cai, Jian-Feng ;
Osher, Stanley ;
Shen, Zuowei .
MULTISCALE MODELING & SIMULATION, 2009, 8 (02) :337-369
[8]   Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data sets [J].
Chen, Guang-Hong ;
Tang, Jie ;
Leng, Shuai .
MEDICAL PHYSICS, 2008, 35 (02) :660-663
[9]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[10]   Multienergy Photon-counting K-edge Imaging: Potential for Improved Luminal Depiction in Vascular Imaging [J].
Feuerlein, Sebastian ;
Roessl, Ewald ;
Proksa, Roland ;
Martens, Gerhard ;
Klass, Oliver ;
Jeltsch, Martin ;
Rasche, Volker ;
Brambs, Hans-Juergen ;
Hoffmann, Martin H. K. ;
Schlomka, Jens-Peter .
RADIOLOGY, 2008, 249 (03) :1010-1016