Sutureless technique for repositioning and scleral fixation of the capsular bag-intraocular lens complex with permanent use of iris retractors

被引:4
作者
Krix-Jachym, Karolina M. [1 ]
Blagun, Natalia [1 ]
Kicinska, Aleksandra K. [1 ]
Dyda, Wojciech [1 ]
Rekas, Marek T. [1 ]
机构
[1] Mil Inst Med, Dept Ophthalmol, Warsaw, Poland
关键词
TENSION RING; PHACOEMULSIFICATION; STABILIZATION; EYES; MANAGEMENT; MICROHOOK; DEVICE; HOOKS;
D O I
10.1097/j.jcrs.0000000000000838
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
A new sutureless technique used for repositioning and scleral fixation of the capsular bag-intraocular lens (IOL) complex in the surgical treatment of subluxated lenses is described. Iris retractors were used not only to induce a tent effect on the capsule but also to permanently fix the capsular bag to the sclera in this method, without the need to prepare scleral or conjunctival flaps. Surgery with the use of a capsular tension ring ( CTR) and iris retractors, the ends of which were brought out through the sclera and cauterized, was performed in 7 eyes of 7 patients with moderate or severe subluxation of the crystalline lens. In all cases, simultaneous use of a CTR and iris retractors ensured good centration of the capsular bag-IOL complex. The method was safe and effective in fixing the capsule to the sclera in the case of significant damage to the ligamentous apparatus of the lens. Copyright (c) 2021 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:118 / 124
页数:7
相关论文
共 23 条
  • [11] Glued capsular hook: Technique for fibrin glue-assisted sutureless transscleral fixation of the capsular bag in subluxated cataracts and intraocular lenses
    Jacob, Soosan
    Agarwal, Amar
    Agarwal, Athiya
    Agarwal, Ashvin
    Narasimhan, Smita
    Kumar, Dhivya Ashok
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12) : 1958 - 1965
  • [12] Intra-scleral fixation of the iris hooks for trans-scleral capsular bag fixation in patient with zonular dialysis
    Karadag, Remzi
    Sari, Unsal
    Gunes, Bahar
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (04) : 1765 - 1768
  • [13] Position of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography
    Kohnen, Thomas
    Cichocki, Magda
    Koss, Michael J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01) : 114 - 120
  • [14] Microhook capsule stabilization for phacoemulsification in eyes with pseudoexfoliation-syndrome-induced lens instability
    Lee, V
    Bloom, P
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (12) : 1567 - 1570
  • [15] The capsular tension ring: Designs, applications, and techniques
    Menapace, R
    Findl, O
    Georgopoulos, M
    Rainer, G
    Vass, C
    Schmetterer, K
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (06) : 898 - 912
  • [16] Iris hooks for phacoemulsification of the subluxated lens
    Merriam, JC
    Zheng, L
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) : 1295 - 1297
  • [17] Capsular stabilization device to preserve lens capsule integrity during phacoemulsification with a weak zonule
    Nishimura, E
    Yaguchi, S
    Nishihara, H
    Ayaki, M
    Kozawa, T
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (03) : 392 - 395
  • [18] Flexible iris hooks for phacoemulsification
    Novak, J
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (06) : 828 - 831
  • [19] Rekas M, 2019, VIDEO J CATARACT REF, V35
  • [20] Modified flexible iris retractor to retract superior iris and support inferior capsule in eyes with iris coloboma and inferior zonular deficiency
    Sethi, HS
    Sinha, A
    Pal, N
    Saxena, R
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) : 715 - 716