Calibration-free analysis of steel slag by laser-induced breakdown spectroscopy with combined UV and VIS spectra

被引:35
作者
Kolmhofer, P. J. [1 ]
Eschlboeck-Fuchs, S. [1 ]
Huber, N. [1 ]
Roessler, R. [2 ]
Heitz, J. [1 ]
Pedarnig, J. D. [1 ]
机构
[1] Johannes Kepler Univ Linz, Inst Appl Phys, Christian Doppler Lab Laser Assisted Diagnost, A-4040 Linz, Austria
[2] Voestalpine Stahl GmbH, A-4031 Linz, Austria
关键词
Laser-induced breakdown spectroscopy (LIBS); Calibration-free laser-induced breakdown; spectroscopy (CF-LIBS); Metallurgical slag; Oxide concentration; Combination of UV and VIS spectral ranges; PLASMA SPECTROSCOPY; EQUILIBRIUM; VALIDITY; SAMPLES;
D O I
10.1016/j.sab.2015.02.004
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Slag from secondary metallurgy in industrial steel production is analyzed by calibration-free laser-induced breakdown spectroscopy (CF-LIBS). The slag pieces are homogenized by ball milling and sintering. LIBS spectra are measured under ambient conditions using nanosecond Nd:YAG laser pulses (1064 nm) for ablation. A fiber-coupled Echelle spectrometer with two separate detection arms in the UV range (190 to 360 nm) and in the VIS range (298 to 864 nm) and one ICCD camera is used for detection. The UV and VIS spectra are measured sequentially and combined to one spectrum to increase the number of-highly resolved emission lines for the calculation of oxide concentrations in slags. The combination of spectra requires an adaption procedure including independent radiometric calibration, the de-convolution of spectrometer functions, baseline corrections, and intensity scaling. More than 60 emission lines of elements Ca, Al, Mg, Si, Fe, Mn, and Ti are evaluated. The electron density is derived from Stark broadening of a Mg line, and the plasma temperature is determined from Saha-Boltzmann plots of Ca, Mn, or Ti lines. With the combined LIBS spectra, the CF-LIBS calculated concentrations C-CF are closer to the nominal concentrations C-N determined by x-ray fluorescence spectrometry. Significantly reduced relative errors of concentration e(r) = |C-CF - C-N|/C-N are observed for the oxides CaO, Al2O3, MgO, SiO2, and MnO, and no reduction was found for FeO and the minor phase TiO2. The improved accuracy of concentrations is attributed to a better detection of the major elements Ca, Al, and Si in the combined LIBS spectra. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:67 / 74
页数:8
相关论文
共 26 条
[1]   Application of calibration-free laser-induced breakdown spectroscopy to radially resolved spectra from a copper-based alloy laser-induced plasma [J].
Aguilera, J. A. ;
Aragon, C. ;
Cristoforetti, G. ;
Tognoni, E. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (07) :685-689
[2]   Characterization of a laser-induced plasma by spatially resolved spectroscopy of neutral atom and ion emissions.: Comparison of local and spatially integrated measurements [J].
Aguilera, JA ;
Aragón, C .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (12) :1861-1876
[3]   One-point calibration for calibration-free laser-induced breakdown spectroscopy quantitative analysis [J].
Cavalcanti, G. H. ;
Teixeira, D. V. ;
Legnaioli, S. ;
Lorenzetti, G. ;
Pardini, L. ;
Palleschi, V. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 87 :51-56
[4]   New procedure for quantitative elemental analysis by laser-induced plasma spectroscopy [J].
Ciucci, A ;
Corsi, M ;
Palleschi, V ;
Rastelli, S ;
Salvetti, A ;
Tognoni, E .
APPLIED SPECTROSCOPY, 1999, 53 (08) :960-964
[5]  
Cremers D.A., 2006, Handbook of laser-induced breakdown spectrscopy, Vsecond
[6]   Local Thermodynamic Equilibrium in Laser-Induced Breakdown Spectroscopy: Beyond the McWhirter criterion [J].
Cristoforetti, G. ;
De Giacomo, A. ;
Dell'Aglio, M. ;
Legnaioli, S. ;
Tognoni, E. ;
Palleschi, V. ;
Omenetto, N. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (01) :86-95
[7]   VALIDITY CRITERIA FOR LOCAL THERMODYNAMIC-EQUILIBRIUM IN PLASMA SPECTROSCOPY [J].
FUJIMOTO, T ;
MCWHIRTER, RWP .
PHYSICAL REVIEW A, 1990, 42 (11) :6588-6601
[8]   Laser-induced breakdown spectroscopy of archaeological findings with calibration-free inverse method: Comparison with classical laser-induced breakdown spectroscopy and conventional techniques [J].
Gaudiuso, R. ;
Dell'Aglio, M. ;
De Pascale, O. ;
Loperfido, S. ;
Mangone, A. ;
De Giacomo, A. .
ANALYTICA CHIMICA ACTA, 2014, 813 :15-24
[9]   Effects of non-uniformity of laser induced plasma on plasma temperature and concentrations determined by the Boltzmann plot method: implications from plasma modeling [J].
Gornushkin, I. B. ;
Shabanov, S. V. ;
Merk, S. ;
Tognoni, E. ;
Panne, U. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (10) :1643-1653
[10]  
Griem H R., 1974, Spectral Line Broadening by Plasmas, ppp 226