The effect of dorsal rim loss on the initial stability of the BioMedtrix cementless acetabular cup

被引:8
|
作者
Montgomery, Meredith L. [1 ]
Kim, Stanley E. [1 ]
Dyce, Jonathan [2 ]
Pozzi, Antonio [1 ]
机构
[1] Univ Florida, Coll Vet Med, Comparat Orthopaed Biomech Lab, Gainesville, FL 32611 USA
[2] Ohio State Univ, Ctr Vet Med, Columbus, OH 43210 USA
来源
BMC VETERINARY RESEARCH | 2015年 / 11卷
关键词
Total hip replacement; Dog; Acetabular cup; Dorsal rim; TOTAL HIP-ARTHROPLASTY; 7; DOGS; AUGMENTATION; DISPLACEMENT; IMPLANTATION; REPLACEMENT; DESIGN; FINS; BONE;
D O I
10.1186/s12917-015-0383-z
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: Loss of dorsal acetabular rim (DAR) is a common sequela to canine hip dysplasia. The purpose of this study is to evaluate the effect of DAR loss on the initial stability of the cementless (BFX) acetabular cup. BFX cups were implanted into foam blocks reamed to resemble acetabulae with simulated 0, 25, 50, and 75% DAR loss. Models were tested in edge loading of the lateral surface of the cup with an indenter, and in centered loading with an articulated femoral prosthesis. Additionally, cups were implanted into paired cadaveric canine hemipelves with either no DAR depletion, or removal of 50% of the DAR, and acutely loaded to failure with an articulated femoral prosthesis. Results: Mean load measured at 1 mm cup displacement during edge loading was not significantly different in foam blocks with loss of 0, 25, 50, and 75% DAR (360 +/- 124 N, 352 +/- 42 N, 330 +/- 81 N, 288 +/- 43 N, respectively; P = 0.425). Mean load to failure with centered loads was greatest in blocks with 0% DAR loss (2828 +/- 208 N; P < 0.001), but was not significantly different between 25, 50, and 75% DAR loss (2270 +/- 301 N, 1924 +/- 157 N, 1745 +/- 118 N). In cadaveric testing, neither mean load to failure (P = 0.067), stiffness (P = 0.707), nor energy (P = 0.228) were significantly different in control hemipelves and those with 50% depletion of the DAR. Failure in all acetabulae occurred due to acetabular bone fracture at forces in supraphysiologic ranges. Conclusions: BFX cup stability under normal physiologic loads does not appear to be compromised in acetabulae with up to 50% DAR loss.
引用
收藏
页数:7
相关论文
共 24 条
  • [21] Initial stability of cementless acetabular cups: press-fit and screw fixation interaction—an in vitro biomechanical study
    Tabata T.
    Kaku N.
    Hara K.
    Tsumura H.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (3) : 497 - 502
  • [22] Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysis
    Farid Amirouche
    Giovanni F. Solitro
    Amit Walia
    Mark Gonzalez
    Aimee Bobko
    International Orthopaedics, 2017, 41 : 1527 - 1533
  • [23] Initial stability of cementless acetabular cups using robotic-assisted total hip arthroplasty compared with the conventional manual technique: An in vitro biomechanical study
    Hidaka, Ryo
    Matsuda, Kenta
    Mochizuki, Hidetaka
    Kawano, Hirotaka
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01)
  • [24] Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis
    Wang, Yuzhu
    Wang, Mincong
    Li, Chengguo
    Nakamura, Yoshihiro
    Deng, Liwei
    Yamako, Go
    Chosa, Etsuo
    Pan, Chenglong
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)