摘要
Two simple and low cost bis Schiff base fluorescent colorimetric chemosensors L1 and L2 have been designed and synthesized. These sensors could detect important anion HF2- by change in both absorption and fluorescence intensity in methanol tris HCI buffer (1:1 v/v) solution at physiological pH. The mechanism of selectivity and sensitivity of these receptors to HF2- has proposed to be on the basis of photo-induced electron transfer (PET), chelation enhanced fluoresence (CHEF) and hydrogen bonding mechanism, confirmed by FT-IR, H-1-NMR and ESI-mass spectra. Interestingly, chelation of HF2- to the receptors takes place in 1:2 ratio, which has been confirmed by job plots analysis, ESI-mass spectra, DFT and TD-DFT studies. The detection limits of the probes L1 and L2 for HF2- were determined to be 6.1 mu M for L1 and 3.94 mu M for L2 respectively, on the basis of 3 sigma/K. Importantly, the low detection limits of L1 and L2 for HF2- suggest that L1 and L2 are sensitive sensors for detection of these ions in drinking water. The receptors L1 and L2 can successfully applied for detection and quantification of HF2- in real samples. To the best of our knowledge this is the third report of fluorescent colorimetric chemosensors for HF2- ions.
引用
收藏
页数:11
相关论文
共 55 条
[11]  
2-P
[12]  
Bianchi A, 1997, SUPRAMOLECULAR CHEMISTRY OF ANIONS, P217
[13]   A dipodal molecular probe for naked eye detection of trivalent cations (Al3+, Fe3+and Cr3+) in aqueous medium and its applications in real sample analysis and molecular logic gates [J].
Chandra, Rukmani ;
Manna, Amit Kumar ;
Rout, Kalyani ;
Mondal, Jahangir ;
Patra, Goutam K. .
RSC ADVANCES, 2018, 8 (63) :35946-35958
[14]   SELF-CONSISTENT MOLECULAR-ORBITAL METHODS .15. EXTENDED GAUSSIAN-TYPE BASIS SETS FOR LITHIUM, BERYLLIUM, AND BORON [J].
DILL, JD ;
POPLE, JA .
JOURNAL OF CHEMICAL PHYSICS, 1975, 62 (07) :2921-2923
[15]   OLEX2: a complete structure solution, refinement and analysis program [J].
Dolomanov, Oleg V. ;
Bourhis, Luc J. ;
Gildea, Richard J. ;
Howard, Judith A. K. ;
Puschmann, Horst .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2009, 42 :339-341
[16]   The First Bifluoride Sensor Based on Fluorescent Enhancement [J].
Dutta, Kaku ;
Deka, Ramesh Ch ;
Das, Diganta Kumar .
JOURNAL OF FLUORESCENCE, 2013, 23 (04) :823-828
[17]  
Frisch M. J., 2009, Gaussian 09, Revision D.01
[18]   Anion receptor chemistry: highlights from 1999 [J].
Gale, PA .
COORDINATION CHEMISTRY REVIEWS, 2001, 213 :79-128
[19]   The maiden report of a fluorescent-colorimetric sensor for expeditious detection of bifluoride ion in aqueous media [J].
Ghorai, Anupam ;
Thakur, Santosh S. ;
Patra, Goutam K. .
RSC ADVANCES, 2016, 6 (110) :108717-108725
[20]  
Ghorai A, 2016, ANAL METHODS-UK, V8, P2032, DOI [10.1039/C5AY03374H, 10.1039/c5ay03374h]