Assessing the SNR Influence in the Estimation of the Mean Frequency of Lower Limbs sEMG Signals

被引:6
作者
Rojas, A. [1 ]
Farfan, A. [1 ]
Mora, E. [2 ]
Minchala, L., I [3 ,4 ]
Wong, S. [3 ]
机构
[1] Univ Cuenca, Cuenca, Ecuador
[2] Univ Cuenca, Dept Elect Elect & Telecommun Engn DEET, Cuenca, Ecuador
[3] Univ Cuenca, Dept Elect Elect & Telecommun Engn, Cuenca 010150, Ecuador
[4] Tecnol Monterrey, Monterrey 64849, Mexico
关键词
Electromyographic; signal to noise ratio; mean frequency; lower limbs; ELECTROMYOGRAPHIC ACTIVITY; MUSCLE; FATIGUE; TIME; EMG; FORCE;
D O I
10.1109/TLA.2018.8528223
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The mean frequency of the power spectrum (MNF) is commonly used to describe the frequency content of an electromyographic (EMG) signal. The objective of this study is to determine the minimum/desirable signal to noise ratio (SNR) value to achieve a reliable measurement of the MNF in superficial EMG (sEMG) signals of lower limbs during gait. To this end, measurements of MNF and SNR were taken in nine muscles of 21 healthy subjects, and recorded signals were contaminated with different noise levels. The minimum threshold of a desirable SNR was determined using the K-means algorithm. A lower bound of 10.11 dB was determined as the SNR value for sEMG acquisition, while 15.78 dB is the minimum SNR value desired for recording sEMG signals. The methodology presented throughout this paper helps in the determination of the minimum SNR value necessary to validate the sEMG acquisition process that can be used, for example, as a control signal for identifying motion intention in the development of control systems devoted for a lower limb exoskeleton.
引用
收藏
页码:2108 / 2114
页数:7
相关论文
共 21 条
[1]   Design and control of hybrid actuation lower limb exoskeleton [J].
Aguilar-Sierra, Hipolito ;
Yu, Wen ;
Salazar, Sergio ;
Lopez, Ricardo .
ADVANCES IN MECHANICAL ENGINEERING, 2015, 7 (06) :1-13
[2]   Time and Frequency Patterns Identification of sEMG Signals Using Hilbert-Huang Transform [J].
Altamirano, A. ;
Vera, A. ;
Munoz, R. ;
Leija, L. ;
Wolf, D. .
IEEE LATIN AMERICA TRANSACTIONS, 2017, 15 (10) :1881-1887
[3]  
Arduino, 2014, ARD MEG 2560, VXXXIII, P81
[4]   EMG frequency content changes with increasing force and during fatigue in the quadriceps femoris muscle of men and women [J].
Bilodeau, M ;
Schindler-Ivens, S ;
Williams, DM ;
Chandran, R ;
Sharma, SS .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (01) :83-92
[5]   Evaluation of a Double Threshold Algorithm to Detect Electromyographic Activity in the Healthy and Paretic Tibialis Anterior Muscle [J].
Bonell, C. E. ;
Tabernig, C. B. ;
Spaich, E. G. .
VI LATIN AMERICAN CONGRESS ON BIOMEDICAL ENGINEERING (CLAIB 2014), 2014, 49 :940-943
[6]   THE MEAN FREQUENCY OF THE EMG OF THE KNEE EXTENSORS IS TORQUE DEPENDENT BOTH IN THE UNFATIGUED AND THE FATIGUED STATES [J].
GERDLE, B ;
KARLSSON, S .
CLINICAL PHYSIOLOGY, 1994, 14 (04) :419-432
[7]   DEPENDENCE OF THE MEAN POWER FREQUENCY OF THE ELECTROMYOGRAM ON MUSCLE FORCE AND FIBER TYPE [J].
GERDLE, B ;
HENRIKSSONLARSEN, K ;
LORENTZON, R ;
WRETLING, ML .
ACTA PHYSIOLOGICA SCANDINAVICA, 1991, 142 (04) :457-465
[8]   Frequency analysis of lower extremity electromyography signals for the quantitative diagnosis of dystonia [J].
Go, Shanette A. ;
Coleman-Wood, Krista ;
Kaufman, Kenton R. .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2014, 24 (01) :31-36
[9]  
Jamal M. Z., 2012, SIGNAL ACQUISITION U, P427
[10]   Establishment of a recording method for surface electromyography in the iliopsoas muscle [J].
Jiroumaru, Takumi ;
Kurihara, Toshiyuki ;
Isaka, Tadao .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2014, 24 (04) :445-451