Direct potentiometry and potentiotitrimetry of warfarin and ibuprofen in pharmaceutical preparations using PVC ferroin-based membrane sensors

被引:32
作者
Hassan, SSM [1 ]
Mahmoud, WH [1 ]
Abdel-Samad, MS [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Dept Chem, Cairo, Egypt
关键词
direct potentiometry; potentiotitrimetry; pharmaceutical analysis; warfarin; ibuprofen; ferroin; membrane sensors; ion-selective electrode;
D O I
10.1007/BF01244748
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sensitive and fast-responding potentiometric sensors are described for the determination of warfarin and ibuprofen. They consist of PVC matrix membranes containing the drug-ferroin ion-association complexes as electroactive materials and dioctylphthalate as a solvent mediator. Linear dynamic response range between 1 x 10(-2) and 2 x 10(-5) M with Nernstian slopes of 59-60 mV/decade concentration and a detection limit of 0.8-1.3 mu g/ml are obtained. A. wide range of organic anions and drug excipients do not interfere. Titration of the drugs with a standard ferroin solution using either a drug-ferroin or ferroin-TPB PVC sensor in conjunction with an Ag-AgCl reference electrode displays S-shaped titration curves with sharp potential breaks at stoichiometric 1:2 (ferroin:dreg) reaction, Differential titration curves with well-defined peaks at the equivalence points are obtained using drug-ferroin/ferroin-TPB PVC membrane sensors. Direct potentiometry and potentiotitrimetry of warfarin and ibuprofen in various pharmaceutical preparations are presented and compared. Several advantages over the pharmacopoeial methods and other techniques in current use are offered by the proposed technique.
引用
收藏
页码:251 / 257
页数:7
相关论文
共 32 条
[1]  
BELAL F, 1985, MIKROCHIM ACTA, V2, P145
[2]  
CARTER SR, 1992, J CHROMATOGR-BIOMED, V112, P77
[3]  
Cosofret V.V., 1992, PHARM APPL MEMBRANE
[4]   RECENT ADVANCES IN PHARMACEUTICAL ANALYSIS WITH POTENTIOMETRIC MEMBRANE SENSORS [J].
COSOFRET, VV ;
BUCK, RP .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1993, 24 (01) :1-58
[5]   DETERMINATION OF WARFARIN IN DRINKING-WATER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER SOLID-PHASE EXTRACTION [J].
DALBACKE, J ;
DAHLQUIST, I ;
PERSSON, C .
JOURNAL OF CHROMATOGRAPHY, 1990, 507 :381-387
[6]  
DAVIES JEW, 1973, LAB PRACT, V22, P20
[7]   THE ANALYSIS OF IBUPROFEN ENANTIOMERS IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON AN ALPHA-1-ACID GLYCOPROTEIN CHIRAL STATIONARY-PHASE [J].
DEVRIES, JX ;
SCHMITZKUMMER, E ;
SIEMON, D .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (10) :2127-2145
[8]   QUANTITATION IN CHIRAL CAPILLARY ELECTROPHORESIS - THEORETICAL AND PRACTICAL CONSIDERATIONS [J].
DHULST, A ;
VERBEKE, N .
ELECTROPHORESIS, 1994, 15 (06) :854-863
[9]  
ELRAGEHY NA, 1994, ANAL LETT, V27, P2127
[10]   USE OF CYCLODEXTRINS IN CAPILLARY ELECTROPHORESIS FOR THE CHIRAL RESOLUTION OF SOME 2-ARYLPROPIONIC ACID NONSTEROIDAL ANTIINFLAMMATORY DRUGS [J].
FANALI, S ;
ATURKI, Z .
JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (01) :297-305