Compound Poisson Noise Verification for X-ray Flat Panel Imager

被引:0
作者
Hsieh, Ho-Hui [1 ]
Ni, Yu-Ching [1 ]
Tseng, Sheng-Pin [1 ]
Tseng, Fan-Pin [1 ]
Chen, Liang-Cheng [1 ]
机构
[1] Inst Nucl Energy Res, Div Hlth Phys, Taoyuan, Taiwan
来源
2015 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST) PROCEEDINGS | 2015年
关键词
radiography; x-ray detectors; noise; ENERGY-INTEGRATING DETECTORS; RECONSTRUCTION; PERFORMANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Physical effects that contribute to the noise in digital radiography are possible to be represented as overall variance including Poisson statistics of x-rays. For real system, statement of the noise response must be integrated against a spectrum to get the total response to spectral fluence of x-ray, that the detected x-ray follows a compound-Poisson distribution. To verify the noise property of our x-ray flat-panel detector (FPD), we formulate a compound-Poisson based model to verify the image noise statistic from measured data. Results demonstrate that the FPD noise property is independed from the tube voltage; only 1.6% error is occurred by the model fitting. In this case, the noise property of our FPD can accurately be represented as the modeled function.
引用
收藏
页码:422 / 426
页数:5
相关论文
共 50 条
  • [21] Single-shot dual-energy x-ray imaging with a flat-panel sandwich detector for preclinical imaging
    Han, Jong Chul
    Kim, Ho Kyung
    Kim, Dong Woon
    Yun, Seungman
    Youn, Hanbean
    Kam, Soohwa
    Tanguay, Jesse
    Cunningham, Ian A.
    CURRENT APPLIED PHYSICS, 2014, 14 (12) : 1734 - 1742
  • [22] Performance of mobile digital X-ray fluoroscopy using a novel flat panel detector for intraoperative use
    Jeong, Chang-Won
    Ryu, Jong-Hyun
    Joo, Su-Chong
    Jun, Hong-Young
    Heo, Dong-Woon
    Lee, Jinseok
    Kim, Kyong-Woo
    Yoon, Kwon-Ha
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (03) : 365 - 372
  • [23] Progress report on the performance of real time selenium flat panel detectors for direct X-ray Imaging
    Tousignant, O
    Choquette, M
    Demers, Y
    Laperrière, L
    Leboeuf, J
    Honda, M
    Nishiki, M
    Takahashi, A
    Tsukamoto, A
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 503 - 510
  • [24] Measurement of the electrical properties of a polycrystalline cadmium telluride for direct conversion flat panel x-ray detector
    Oh, K. M.
    Kim, D. K.
    Shin, J. W.
    Heo, S. U.
    Kim, J. S.
    Park, J. G.
    Nam, S. H.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [25] Soft X-ray Imager of the Xtend system on board XRISM
    Noda, Hirofumi
    Mori, Koji
    Tomida, Hiroshi
    Nakajima, Hiroshi
    Tanaka, Takaaki
    Murakami, Hiroshi
    Uchida, Hiroyuki
    Suzuki, Hiromasa
    Kobayashi, Shogo Benjamin
    Yoneyama, Tomokage
    Hagino, Kouichi
    Nobukawa, Kumiko
    Uchiyama, Hideki
    Nobukawa, Masayoshi
    Matsumoto, Hironori
    Tsuru, Takeshi Go
    Yamauchi, Makoto
    Hatsukade, Isamu
    Odaka, Hirokazu
    Kohmura, Takayoshi
    Yamaoka, Kazutaka
    Yoshida, Tessei
    Kanemaru, Yoshiaki
    Hiraga, Junko
    Dotani, Tadayasu
    Ozaki, Masanobu
    Tsunemi, Hiroshi
    Sato, Jin
    Takaki, Toshiyuki
    Terada, Yuta
    Miyazaki, Keitaro
    Kusunoki, Kohei
    Otsuka, Yoshinori
    Yokosu, Haruhiko
    Yonemaru, Wakana
    Ichikawa, Kazuhiro
    Nakano, Hanako
    Takemoto, Reo
    Matsushima, Tsukasa
    Urase, Reika
    Kurashima, Jun
    Fuchi, Kotomi
    Hayakawa, Kaito
    Fukuda, Masahiro
    Kamei, Takamitsu
    Asahina, Yoh
    Inoue, Shun
    Amano, Yuki
    Aoki, Yuma
    Ito, Yamato
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 2025,
  • [26] Report on recent results of the PERCIVAL soft X-ray imager
    Khromova, A.
    Cautero, G.
    Giuressi, D.
    Menk, R.
    Pinaroli, G.
    Stebel, L.
    Correa, J.
    Marras, A.
    Wunderer, C. B.
    Lange, S.
    Tennert, M.
    Niemann, M.
    Hirsemann, H.
    Smoljanin, S.
    Reza, S.
    Graafsma, H.
    Goettlicher, P.
    Shevyakov, I.
    Supra, J.
    Xia, Q. d
    Zimmer, M.
    Guerrini, N.
    Marsh, B.
    Sedgwick, I.
    Nicholls, T.
    Turchetta, R.
    Pedersen, U.
    Tartoni, N.
    Hyun, H. J.
    Kim, K. S.
    Rah, S. Y.
    Hoenk, M. E.
    Jewell, A. D.
    Jones, T. J.
    Nikzad, S.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [27] SuperAGILE: The hard X-ray imager for the AGILE space mission
    Feroci, M.
    Costa, E.
    Soffitta, P.
    Del Monte, E.
    Di Persio, G.
    Donnarumma, I.
    Evangelista, Y.
    Frutti, M.
    Lapshov, I.
    Lazzarotto, F.
    Mastropietro, M.
    Morelli, E.
    Pacciani, L.
    Porrovecchio, G.
    Rapisarda, M.
    Rubini, A.
    Tavani, M.
    Argan, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (03) : 728 - 754
  • [28] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [29] Gain Correction for an X-ray Imaging System With a Movable Flat Panel Detector and Intrinsic Localization Crosshair
    Park, Yang-Kyun
    Sharp, Gregory C.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (02) : 387 - 395
  • [30] A 128-Channel CMOS Charge Readout ASIC for Flat-Panel X-Ray Detectors
    Adachi, Susumu
    Nishimura, Akihiro
    Yoshimlita, Toshinori
    Tanabe, Koichi
    Okamura, Shoichi
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (06) : 3673 - 3683