A simplified and standardized neutralization enzyme immunoassay for the quantification of measles neutralizing antibody

被引:34
作者
Lee, MS [1 ]
Cohen, B
Hand, J
Nokes, DJ
机构
[1] Univ Oxford, Wellcome Ctr Epidemiol Infect Dis, Oxford OX1 3PS, England
[2] Univ Warwick, Dept Biol Sci, Coventry CV4 7AL, W Midlands, England
[3] Cent Publ Hlth Lab, Enter & Resp Virus Lab, London NW9 5HT, England
关键词
neutralizing antibody; neutralization test; measles virus; measles immunity; laboratory diagnosis;
D O I
10.1016/S0166-0934(98)00178-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simplified and standardized neutralization enzyme immunoassay (Nt-EIA) was developed to detect measles Virus growth in Vero cells and to quantify measles neutralizing antibody. Heat-inactivated sera were diluted serially 4-fold and tested in duplicate. The 50% reduction point (50%RP) of virus growth was calculated using the Reed-Muench formula and the neutralizing antibody titre of test sera was converted into mIU/ml by comparing their 50%RP with that of the international standard serum. The optimal virus input and incubation time were found to be 50-100 plaque forming unit (PFU)/well and 64-72 h, respectively. The simplified Nt-EIA had a good reproducibility with only 3.7-4.2% of duplicate tests having a ratio >4 in an evaluation of intra assay Variation and the coefficients of variance were 2-9% in an evaluation of inter assay variation. In addition, the simplified Nt-EIA had a high sensitivity (98.6%). specificity (100%) and agreement (98.8%) in qualitative comparison with plaque reduction neutralization test (PRNT). In quantitative comparison, the correlation coefficient between Nt-EIA and PRNT was 0.83 without log transformation or 0.77 after log transformation and 90% of 61 positive sera had a ratio <4 between antibody titre tested by the two methods. The simplified Nt-EIA is thus a suitable alternative to the PRNT for the quantification of measles neutralizing antibody. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:209 / 217
页数:9
相关论文
共 31 条
[11]  
Dean AG, 1994, EPI INFO VERSION 6 0
[12]   EVALUATION OF MONOCLONAL ANTIBODY-BASED CAPTURE ENZYME IMMUNOASSAYS FOR DETECTION OF SPECIFIC ANTIBODIES TO MEASLES-VIRUS [J].
ERDMAN, DD ;
ANDERSON, LJ ;
ADAMS, DR ;
STEWART, JA ;
MARKOWITZ, LE ;
BELLINI, WJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (07) :1466-1471
[13]   EQUIVALENCE OF WEIGHTED KAPPA AND INTRACLASS CORRELATION COEFFICIENT AS MEASURES OF RELIABILITY [J].
FLEISS, JL ;
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1973, 33 (03) :613-619
[14]   THE 1ST INTERNATIONAL STANDARD FOR ANTI-MEASLES SERUM [J].
FORSEY, T ;
HEATH, AB ;
MINOR, PD .
BIOLOGICALS, 1991, 19 (03) :237-241
[15]  
FRASER KB, 1978, MEASLES VIRUS ITS BI, P66
[16]   MEASLES - STATE-OF-THE-ART AND FUTURE-DIRECTIONS [J].
GELLIN, BG ;
KATZ, SL .
JOURNAL OF INFECTIOUS DISEASES, 1994, 170 :S3-S14
[17]  
Gershon A, 1979, DIAGNOSTIC PROCEDURE, P665
[18]  
GRANDIEN M, 1994, B WORLD HEALTH ORGAN, V72, P207
[19]   An evaluation of nine commercial EIA kits for the detection of measles specific IgG [J].
Hesketh, L ;
Charlett, A ;
Farrington, P ;
Miller, E ;
Forsey, T ;
MorganCapner, P .
JOURNAL OF VIROLOGICAL METHODS, 1997, 66 (01) :51-59
[20]   ANTIBODIES TO PUUMALA VIRUS IN HUMANS DETERMINED BY NEUTRALIZATION TEST [J].
HORLING, J ;
LUNDKVIST, A ;
HUGGINS, JW ;
NIKLASSON, B .
JOURNAL OF VIROLOGICAL METHODS, 1992, 39 (1-2) :139-147