Reagentless Amperometric Glucose Biosensors: Ferrocene-Tethering and Copolymerization

被引:13
作者
Altun, Ayhan [1 ]
Apetrei, Roxana-Mihaela [1 ,2 ]
Camurlu, Pinar [1 ]
机构
[1] Akdeniz Univ, Dept Chem, TR-07058 Antalya, Turkey
[2] Dunarea de Jos Univ Galati, RO-800008 Galati, Romania
关键词
Sensors; Electroanalytical Electrochemistry; Bioelectrochemistry; CONDUCTING POLYMER; ELECTROCHROMIC PROPERTIES; ELECTRON-TRANSFER; ENZYME ELECTRODE; REDOX MEDIATOR; OXIDASE; IMMOBILIZATION; ELECTROCHEMISTRY; PHENOTHIAZINE; CONSTRUCTION;
D O I
10.1149/1945-7111/ab9c81
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Ferrocene-substituted 2,5-di(thienyl)pyrrole (SNS-Fc) was electrochemically polymerized in the presence and absence of 3,4-ethylenedioxythiophene (EDOT) and utilized for biosensing upon immobilization of glucose oxidase (GOD) through cross-linking. The two biosensors, homopolymer P(SNS-Fc) and copolymer-based P(SNS-Fc-co-EDOT) were evaluated by comparison in terms of analytical performance. Due to the conducting-redox active nature of the films, the study was able to consider the developed sensors both as "first generation," monitoring H(2)O(2)oxidation and as "second generation," using the optimum potential for ferrocene oxidation. The difference in performance at these two working potentials served as assessment of the influence of ferrocene moiety within the conducting film. In the scope of further improvement, carbon nanotubes (MWCNTs) were incorporated in both type systems. This improved the detection efficiency leading to extension of linear range up to 1.5 mM with sensitivity up to 23.12 mu A mM(-1)cm(-2)and detection limits as low as 0.43 mu M. The proposed biosensors showed little to no interference to other saccharides and accurate recovery in real sample analysis, especially when glucose detection was based on mediated electron transfer. Thus, the association of ferrocene, poly 2,5-di(thienyl)pyrroles and CNTs is highly efficient in the development of sensitive "reagentless" biosensor systems.
引用
收藏
页数:8
相关论文
共 57 条
[11]   Anion recognition by functionalized single wall carbon nanotubes [J].
Callegari, A ;
Marcaccio, M ;
Paolucci, D ;
Paolucci, F ;
Tagmatarchis, N ;
Tasis, D ;
Vázquez, E ;
Prato, M .
CHEMICAL COMMUNICATIONS, 2003, (20) :2576-2577
[12]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[13]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[14]   Preparation, characterisation and biosensor application of conducting polymers based on ferrocene substituted thiophene and terthiophene [J].
Chen, J ;
Burrell, AK ;
Collis, GE ;
Officer, DL ;
Swiegers, GF ;
Too, CO ;
Wallace, GG .
ELECTROCHIMICA ACTA, 2002, 47 (17) :2715-2724
[15]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[16]   ELECTROCHEMICAL TECHNIQUES FOR THE DEVELOPMENT OF AMPEROMETRIC BIOSENSORS [J].
DAVIS, G .
BIOSENSORS, 1985, 1 (02) :161-178
[17]   Development of glucose biosensor based on reconstitution of glucose oxidase onto polymeric redox mediator coated pencil graphite electrodes [J].
Dervisevic, Muamer ;
Cevik, Emre ;
Senel, Mehmet .
ENZYME AND MICROBIAL TECHNOLOGY, 2015, 68 :69-76
[18]  
Dyer A. L., 2007, HDB CONDUCTING POLYM
[19]   Synthesis of New Thienylene Pyrrole Monomers and Their Electropolymerizations [J].
Eken, Serap ;
Carbas, Buket Bezgin ;
Akdag, Akin ;
Onal, Ahmet M. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (14) :G115-G121
[20]   N-substituted 2,5-Di(2-thienyl)pyrroles. Synthesis and electrochemical properties [J].
El'shina, T. S. ;
Sosnin, E. A. ;
Shklyaeva, E. V. ;
Abashev, G. G. .
RUSSIAN JOURNAL OF GENERAL CHEMISTRY, 2013, 83 (04) :726-730