X-ray microtomographic evaluation of the absolute marginal fit of fixed prostheses made from soft Co-Cr and zirconia

被引:6
作者
Daou, Elie E. [1 ]
机构
[1] Fac Dent Med, Fac Dent, Dept Prosthodont, Beirut, Lebanon
关键词
DENTAL PROSTHESES; INTERNAL ADAPTATION; PARTIAL DENTURES; CLINICAL FIT; CERAMIC CROWNS; BOND STRENGTH; DISCREPANCIES; FRAMEWORKS; PRECISION; THICKNESS;
D O I
10.1016/j.prosdent.2020.07.031
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem.The absolute marginal fit of CAD-CAM presintered fixed partial dentures has been poorly documented. Purpose. The purpose of this in vitro study was to evaluate the marginal fit of presintered cobalt- chromium (Co-Cr) and zirconia 3-unit fixed partial dentures by using X-ray microcomputed tomography (mu CT). Material and methods. A metal model was prepared from a typodont to receive fixed partial dentures (N=12). The maxillary first premolar and first molar were prepared with a circumferential 1.2-mm chamfer and 2-mm occlusal reduction. The dies were scanned and assigned to 1 of 2 groups to receive the prostheses made of presintered Co-Cr or presintered zirconia (n=6). Each framework was seated on its model without load application. The abutments were scanned by using mu CT. A circle with 10 diameters, with a step of 18 degrees, was projected at the center of the obtained image. Absolute marginal discrepancy and marginal gap mean values were measured, and overextended and underextended margins determined. The data were analyzed by using the Levene t test and ANOVA (alpha=.05). Results. No statistically significant difference was found in the marginal fit between the materials tested (P=.939). The mean values were 66 +/- 14 mu m for Co-Cr and 61 +/- 12 mu m for zirconia. The absolute marginal discrepancy mean value for the premolar was 69 +/- 12 mu m and 41 +/- 9 mu m for the molar (P<.001). Overextension was predominant for both materials tested, with a higher percentage reported for the zirconia group. Conclusions. Presintered alloys presented clinically acceptable adaptation with a predominance of marginal overextensions.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 56 条
  • [1] Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain
    Akova, Tolga
    Ucar, Yurdanur
    Tukay, Alper
    Balkaya, Mehmet Cudi
    Brantley, William A.
    [J]. DENTAL MATERIALS, 2008, 24 (10) : 1400 - 1404
  • [2] [Anonymous], 2015, BRUK MICRO CT AC
  • [3] The evolution of rapid prototyping in dentistry: a review
    Azari, Abbas
    Nikzad, Sakineh
    [J]. RAPID PROTOTYPING JOURNAL, 2009, 15 (03) : 216 - 225
  • [4] Marginal and internal fits of fixed dental prostheses zirconia retainers
    Beuer, Florian
    Aggstaller, Hans
    Edelhoff, Daniel
    Gernet, Wolfgang
    Sorensen, John
    [J]. DENTAL MATERIALS, 2009, 25 (01) : 94 - 102
  • [5] Precision of fit: zirconia three-unit fixed dental prostheses
    Beuer, Florian
    Naumann, Michael
    Gernet, Wolfgang
    Sorensen, John A.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2009, 13 (03) : 343 - 349
  • [6] Bindl A, 2007, INT J PERIODONT REST, V27, P567
  • [7] Clinical fit of Procera AllCeram crowns
    Boening, KW
    Wolf, BH
    Schmidt, AE
    Kästner, K
    Walter, MH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) : 419 - 424
  • [8] Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
    Borba, Marcia
    Miranda, Walter Gomes, Jr.
    Cesar, Paulo Francisco
    Griggs, Jason Allan
    Della Bona, Alvaro
    [J]. BRAZILIAN ORAL RESEARCH, 2013, 27 (05) : 396 - 402
  • [9] Adaptation of all-ceramic fixed partial dentures
    Borba, Marcia
    Cesar, Paulo F.
    Griggs, Jason A.
    Della Bona, Alvaro
    [J]. DENTAL MATERIALS, 2011, 27 (11) : 1119 - 1126
  • [10] In Vitro Marginal Fit of Three All-Ceramic Crown Systems Before and After Cementation
    Borges, G. A.
    Faria, J. S.
    Agarwal, P.
    Spohr, A. M.
    Correr-Sobrinho, L.
    Miranzi, B. A. S.
    [J]. OPERATIVE DENTISTRY, 2012, 37 (06) : 641 - 649