Modelling of internal structures and electrodes in electrical process tomography

被引:20
|
作者
Heikkinen, LM [1 ]
Vauhkonen, M [1 ]
Savolainen, T [1 ]
Kaipio, JP [1 ]
机构
[1] Univ Kuopio, Dept Appl Phys, FIN-70211 Kuopio, Finland
关键词
resistivity distribution; electrical process tomography; internal structures; internal electrodes; industrial process monitoring;
D O I
10.1088/0957-0233/12/8/304
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Classical electrical impedance tomography is an imaging modality in which the internal impedivity distribution is reconstructed from the known injected currents and voltages measured on the surface of the object. However. in many industrial cases there are a priori known internal structures inside the vessels which could be used as internal electrodes in tomographical imaging. In this paper we consider modelling of certain types of internal structures and using them as internal electrodes in two-dimensional electrical process tomography. We also propose an inversion approach in which directional smoothness of the resistivity distribution can be taken into account. Simulations and laboratory experiments show that. by utilizing internal structural information and using these internal structures as additional electrodes. we can achieve significant improvements in image reconstruction. Improvements are shown for the cases in which the electrodes are placed at the centre of the object and are surrounded by a resistive layer.
引用
收藏
页码:1012 / 1019
页数:8
相关论文
共 50 条
  • [1] Electrical process tomography with known internal structures and resistivities
    Heikkinen, LM
    Vauhkonen, M
    Savolainen, T
    Leinonen, K
    Kaipio, JP
    INVERSE PROBLEMS IN ENGINEERING, 2001, 9 (05): : 431 - 454
  • [2] Electrical Capacitance Tomography Sensor Using Internal Electrodes
    Cui, Ziqiang
    Xia, Zihan
    Wang, Huaxiang
    IEEE SENSORS JOURNAL, 2020, 20 (06) : 3207 - 3216
  • [3] The Effect of Internal Electrodes on Electrical Impedance Tomography Sensitivity
    Stowe, Symon
    Adler, Andy
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 1457 - 1460
  • [4] Electrical Resistance Tomography-Based Sensing Skin with Internal Electrodes for Crack Detection in Large Structures
    Rashetnia, Reza
    Alla, Omar Khalaf
    Gonzalez-Berrios, Guillermo
    Seppanen, Aku
    Pour-Ghaz, Mohammad
    MATERIALS EVALUATION, 2018, 76 (10) : 1405 - 1413
  • [5] Boundary element method and internal electrodes in electrical impedance tomography
    Tarvainen, M
    Vauhkonen, M
    Savolainen, T
    Kaipio, JP
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2001, 50 (04) : 809 - 824
  • [6] An electrical capacitance tomography sensor with internal-external electrodes
    Liu, S
    Yang, WQ
    Wang, H
    PROCESS IMAGING FOR AUTOMATIC CONTROL, 2001, 4188 : 300 - 307
  • [7] Dynamic electrical impedance tomography with known internal structures
    Kim, KY
    Kang, SI
    Kim, MC
    Kim, S
    Lee, YJ
    Vauhkonen, M
    INVERSE PROBLEMS IN ENGINEERING, 2003, 11 (01): : 1 - 19
  • [8] Comparison of Electrical Capacitance Tomography Sensors with Internal-External Electrodes
    Ge, Ruihuan
    Ye, Jiamin
    Wang, Haigang
    2013 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST 2013), 2013, : 31 - 34
  • [9] A Local Region of Interest Imaging Method for Electrical Impedance Tomography with Internal Electrodes
    Kwon, Hyeuknam
    McEwan, Alistair L.
    Oh, Tong In
    Farooq, Adnan
    Woo, Eung Je
    Seo, Jin Keun
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [10] Dynamic image reconstruction in electrical impedance tomography with known internal structures
    Kim, KY
    Kang, SI
    Kim, MC
    Kim, S
    Lee, YJ
    Vauhkonen, M
    IEEE TRANSACTIONS ON MAGNETICS, 2002, 38 (02) : 1301 - 1304