Tomotherapy

被引:354
作者
Mackie, TR [1 ]
Balog, J [1 ]
Ruchala, K [1 ]
Shepard, D [1 ]
Aldridge, S [1 ]
Fitchard, E [1 ]
Reckwerdt, P [1 ]
Olivera, G [1 ]
McNutt, T [1 ]
Mehta, M [1 ]
机构
[1] Univ Wisconsin, Sch Med, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S1053-4296(99)80058-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Tomotherapy is delivery of intensity-modulated, rotational radiation therapy using a fan-beam delivery. The NOMOS (Sewickley, PA) Peacock system is an example of sequential (or serial) tomotherapy that uses a fast-moving, actuator-driven multileaf collimator attached to a conventional C-arm gantry to modulate the beam intensity. In helical tomotherapy, the patient is continuously translated through a ring gantry as the fan beam rotates. The beam delivery geometry is similar to that of helical computed tomography (CT) and requires the use of slip rings to transmit power and data. A ring gantry provides a stable and accurate platform to perform tomographic verification using an unmodulated megavoltage beam. Moreover, megavoltage tomograms have adequate tissue contrast and resolution to provide setup verification. Assuming only translational and rotational offset errors, it is also possible to determine the offsets directly from tomographic projections, avoiding the time-consuming image reconstruction operation. The offsets can be used to modify the leaf delivery pattern to match the beam to the patient's anatomy on each day of a course of treatment. If tomographic representations of the patient are generated, this information can also be used to perform dose reconstruction. In this way, the actual dose distribution delivered can be superimposed onto the tomographic representation of the patient obtained at the time of treatment. The results can be compared with the planned isodose on the planning CT. This comparison may be used as an accurate basis for adaptive radiotherapy whereby the optimized delivery is modified before subsequent fractions. The verification afforded tomotherapy allows more precise conformal therapy. It also enables conformal avoidance radiotherapy, the complement to conformal therapy, for cases in which the tumor volume is ill-defined, but the locations of sensitive structures are adequately determined. A clinical tomotherapy unit is under construction at the University of Wisconsin.
引用
收藏
页码:108 / 117
页数:10
相关论文
共 23 条
  • [1] BALOG J, 1998, THESIS U WISCONSIN M
  • [2] Brooke A., 1998, GAMS USERS GUIDE
  • [3] Carol MP, 1995, 3-D RADIATION TREATMENT PLANNING AND CONFORMAL THERAPY, P435
  • [4] Cho PS, 1998, MED PHYS MG, P459
  • [5] Fitchard EE, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P185
  • [6] Registration of synthetic tomographic projection data sets using cross-correlation
    Fitchard, EE
    Aldridge, JS
    Reckwerdt, PJ
    Mackie, TR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06) : 1645 - 1657
  • [7] Effects of treatment setup variation on beam's eye view dosimetry for radiation therapy using the multileaf collimator vs the cerrobend block
    Frazier, A
    Yan, D
    Du, M
    Wong, J
    Vicini, F
    Matter, R
    Joyce, M
    Martinez, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05): : 1247 - 1256
  • [8] Gilhuijs KGA, 1997, PROCEEDINGS OF THE XIITH INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY, P31
  • [9] GRACE A, 1995, OPTIMIZATION TOOLBOX
  • [10] GRANT W, 1996, TELETHERAPY PRESENT, P793