Novel design approach for the analysis of laterally unrestrained reinforced concrete slabs considering membrane action

被引:24
作者
Herraiz, B. [1 ]
Vogel, T. [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Struct Engn, CH-8093 Zurich, Switzerland
关键词
Modelling; Concrete slabs; Membrane action; Failure criteria; Comparative assessment; FLOOR SLABS; BEHAVIOR; AMBIENT;
D O I
10.1016/j.engstruct.2016.05.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years, investigations on the behaviour and modelling of laterally unrestrained reinforced concrete slabs have been intensified due to the reserve of strength that membrane action provides. The existing analytical and numerical design approaches do not lead to satisfactory estimations, especially on failure predictions. In this paper, a novel design approach is described. The behaviour of a slab prior to the development of membrane forces is estimated through classic, renowned methods, and the vertical deflection at which membrane action begins by means of a perfect-plastic kinematic model. For larger deflections, an iterative procedure is proposed to find the distribution of membrane forces that satisfy both, equilibrium, and kinematics of the slab. Two failure criteria are included to determine the maximum load-bearing capacity and deflection. The presented approach, together with other existing design methods, are compared with 43 experimental tests of laterally unrestrained slabs conducted by different authors. The comparison illustrates a good correlation between model prediction and test results, and a clearly improved performance in terms of accuracy and precision is achieved. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:313 / 329
页数:17
相关论文
共 31 条
[1]  
[Anonymous], 2011, ROBUSTNESS STRUCTURE
[2]  
[Anonymous], 2013, International Federation for Structural ConcreteFib Model Code for Concrete Structures 2010
[3]   Behaviour of concrete floor slabs at ambient and elevated temperatures [J].
Bailey, C. G. ;
Toh, W. S. .
FIRE SAFETY JOURNAL, 2007, 42 (6-7) :425-436
[4]   The tensile membrane action of unrestrained composite slabs simulated under fire conditions [J].
Bailey, CG ;
White, DS ;
Moore, DB .
ENGINEERING STRUCTURES, 2000, 22 (12) :1583-1595
[5]  
Bailey CG, 2008, ACI STRUCT J, V105, P30
[6]   Small-scale concrete slab tests at ambient and elevated temperatures [J].
Bailey, Colin G. ;
Toh, Wee Siang .
ENGINEERING STRUCTURES, 2007, 29 (10) :2775-2791
[7]  
Brotchie J.F., 1971, CRACKING DEFLECTION, P345
[8]   Failure Assessment of Lightly Reinforced Floor Slabs. II: Analytical Studies [J].
Cashell, K. A. ;
Elghazouli, A. Y. ;
Izzuddin, B. A. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2011, 137 (09) :989-1001
[9]   Failure Assessment of Lightly Reinforced Floor Slabs. I: Experimental Investigation [J].
Cashell, K. A. ;
Elghazouli, A. Y. ;
Izzuddin, B. A. .
JOURNAL OF STRUCTURAL ENGINEERING, 2011, 137 (09) :977-988
[10]  
Draper N.R., 1998, Applied Regression Analysis, V326