Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens

被引:3
|
作者
Hui, Na [1 ]
Chu, Mei-Fang [1 ]
Li, Yan [1 ]
Wang, Cong-Yi [1 ]
Yu, Lei [1 ]
Ma, Bo [1 ]
机构
[1] Xi An Jiao Tong Univ, Shaanxi Eye Hosp, Xian Peoples Hosp, Xian Hosp 4,Affiliated Guangren Hosp,Sch Med, Xian 710004, Shaanxi, Peoples R China
关键词
trifocal intraocular lens; rotationally asymmetric multifocal intraocular lens; visual quality; contrast sensitivity; BILATERAL IMPLANTATION; EXTENDED RANGE; PERFORMANCE; OUTCOMES; CATQUEST-9SF;
D O I
10.18240/ijo.2022.09.08
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To compare visual quality after unilateral cataract surgery with implantation of trifocal intraocular lens (IOL) and asymmetric refractive multifocal IOL. METHODS: The prospective nonrandom, comparative study consisted of 60 eyes of 60 patients suffering unilateral cataract surgery with implantation of two different IOLs: AT LISA tri 839MP (30 eyes; Carl Zeiss Meditec, Germany) and LS-313 MF30 (30 eyes; Oculentis GmbH, Germany). Visual acuity, refractive outcome, contrast sensitivity, defocus curves, quality of vision, and optical phenomena were evaluated at 3mo postoperatively. RESULTS: There were no statistical differences between groups in uncorrected distance visual acuity (P=0.1 3) and uncorrected near visual acuity (P=0.54). In contrast, uncorrected intermediate visual acuity was better in trifocal group compared to the refractive multifocal group (P=0.02). No significant statistical between-group difference was detected in cylinder (P=0.43). Compared to trifocal group, spherical refraction and spherical equivalent in refractive multi focal group were more myopic (P < 0.01). Under photopic conditions, no significant statistical differences were found between groups in contrast sensitivity at 3 and 6 cycles per degree (cpd). The refractive multifocal group performed better at 12 and 18 cpd than the trifocal group (P=0.01, P=0.034, respectively). The questionnaires of quality of vision and optical phenomena showed no differences between groups. CONCLUSION: Trifocal IOL is superior to refractive multifocal IOL in intermediate visual acuity. Rotationally asymmetric refractive multifocal IOL is more myopic in automated refraction and significantly better for the photopic contrast sensitivity at high frequency.
引用
收藏
页码:1460 / 1467
页数:8
相关论文
共 50 条
  • [41] Unilateral Versus Bilateral Refractive Lens Exchange With a Trifocal Intraocular Lens in Emmetropic Presbyopic Patients
    Fernandez-Garcia, Javier L.
    Llovet-Rausell, Andrea
    Ortega-Usobiaga, Julio
    Bilbao-Calabuig, Rafael
    Llovet-Osuna, Fernando
    Druchkiv, Vasyl
    Arias-Puente, Alfonso
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 223 : 53 - 59
  • [42] Differences in visual quality with orientation of a rotationally asymmetric bifocal intraocular lens design
    Radhakrishnan, Aiswaryah
    Dorronsoro, Carlos
    Marcos, Susana
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09): : 1276 - 1287
  • [43] Multifocal intraocular lens implantation in prepresbyopic patients with unilateral cataract
    Jacobi, PC
    Dietlein, TS
    Lüke, C
    Jacobi, FK
    OPHTHALMOLOGY, 2002, 109 (04) : 680 - 686
  • [44] Visual and Refractive Outcomes of a New Hydrophobic Trifocal Toric Intraocular Lens
    Daya, Sheraz
    Lagana, Marcela Espinosa
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 997 - 1007
  • [45] Multifocal intraocular lens implantation in children with unilateral congenital cataracts
    Jiang, Mingming
    Zhang, Jing
    Ding, Yichao
    Huang, Yusen
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (01): : 18 - 23
  • [46] Refractive lens exchange with the Array multifocal intraocular lens
    Packer, M
    Fine, IH
    Hoffman, RS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03): : 421 - 424
  • [47] Refractive lens exchange with an array multifocal intraocular lens
    Dick, HB
    Gross, S
    Tehrani, M
    Eisenmann, D
    Pfeiffer, N
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (05) : 509 - 518
  • [48] A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens
    Lian, Huifang
    Ma, Weisong
    Wei, Qiuhong
    Yuan, Xiaoyong
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (07) : 1607 - 1612
  • [49] Visual results after implantation of a trifocal intraocular lens in high myopes
    Steinwender, Gernot
    Schwarz, Luisa
    Boehm, Myriam
    Slavik-Lencova, Anna
    Hemkeppler, Eva
    Shajari, Mehdi
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (06): : 680 - 685
  • [50] Visual function after implantation of a diffractive aspheric trifocal intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega Cueto, Luis
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    Fernandez-Vega, Luis
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (05) : 405 - 411